ec l
2, February 15, 1990 i
Am. g s
1
- a Docket No. 50 309 i
i 1
l i
Mr."C. D. Frizzle, President Maine Yankee Atomic Power Company j
83 Edison Drive
- Augusta, Maine 04336 u
Dear Mr.' Frizzle:
^
1 n
SUBJECT:
RECEIPT OF RESPONSE TO NRC GENERIC LETTER 89 13:
SERVICE i
'+
WATER SYSTEM PROBLEMS AFFECTING SAFETY.RELATED EQUIPMENT
J We have received your letter dated January 29, 1990, in response to Generic j
' Letter 89 13: Service Water System Problems Affecting Safety.Related Equipment..
J We understand'from your response that you have comitted to activities to address each of-the five recomended actions of Generic Letter 89-13. We
<. remind you that for any course of action different from the recomended actions of the generic letter, you should document and~ retain in appropriate plant records a justifiestion that the heat removal requirements of the service
. water system'are satisfied by use of the alternative program.
>S
_ e look forward to receiving your sumary of recomended improvements and W
V.
schedule for implementation, as stated in your January 29, 1990 letter, by l
p December 31, 1990.
i b b ". L N E*, P N ject Manager Project Directorate 1 3-Division of Reactor. Projects.1/II Office of Nuclear. Reactor Regulation-4:
L cc: See next page l*
DISTRIBUTION:'DocketFile,NRC&PDRs,Eleeds,MRushbrook,'RWessman,ACRS(10),
f
'BBoger, 5Varga, EJordan, JJohnson,Rgn.I, PDI-3 r/f, CHolden,Rgn.I. EMcCabe,Rgn.I, L
2
.AChu,,VHodge-b
/
n
- DFG; 7
- PDI.
/..:PDI.3/PM
- :PDI.3
- .........r:...
L'NAME';MRus rp k.
Eleeds
- RWe man
.....:. v........ :1//,(/90 DATE D/90
- V/4 /90 0FFICIAL' RECORD COPY
~ Document.Name: MAINE YANKEE TAC 74022 GL 8913
~
9002260167 900215 PDR ADOCK 05000309 P.
PNV DFo i llo 3
V Mr. C. D. Frizzle,
cc:
Mr. Charles B. Brinkman Mr. G. D. Whittier, Panager Manager - Washington Nuclear Nuclear Engineering and Licensing Operations Maine Yankee Atomic Power Company Combustion Engineering, Inc.
83 Edison Drive 12300 Twinbrook Parkway, Suite 330 Augusta, Maine 04336 Rockville, Maryland 20852 Mr. Robert W. Blackmore, John A. Ritsher, Esquire Plant Manager Ropes & Gray Maine Yankee Atomic Power Company 225 Franklin Street P.O. Box 408 Boston, Massachusetts 02110 Wiscasset, Maine 04578 State Planning Officer Executive Department 189 State Street Augusta, Maine 04330 Dr. E. T. Boulette, Vice President Operations Maine Yankee Atomic Power Company P. O. Box 408 Wiscasset, Maine 04578 Mr. J. H. Garrity, Vice President Licensing and Engineering Maine Yankee Atomic Power Company 83 Edison Drive l'
Augusta, Maine 04336 Regional Administrator, Region 1 U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, Pennsylvania 19406 First Selectman of Wiscasset l
Municipal Building U.S. Route 1 Wiscasset, Maine 04578 l
Mr. Cornelius F. Holden Resident Inspector l-Maine Yankee Atomic Power Station l-U.S. Nuclear Regulatory Commission l
P. O. Box E Wiscasset, Maine 04578 Mr. P. L. Anderson, Project Manager Yankee Atomic Electric Company 580 Main Street Bolton, Massachusetts 01740-1398