ML20006B402

From kanterella
Jump to navigation Jump to search
Advises That Licensee Performed Further Evaluation of as-installed Bolts,Per Recent Discussions W/Nrc.Engineering Evaluation Documented in Document CPSES-8901654 & Available for NRC Review
ML20006B402
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 01/26/1990
From: William Cahill
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
TXX-90049, NUDOCS 9002020070
Download: ML20006B402 (1)


Text

_ _ _ _ - _.

.m Log # TXX-90049 4

File # 903.9

(

E 20010 nlELECTRIC January 26,' 1990-

. Wlutaen J. Cabul, Jr.

Executive M President U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington,;D. C.

20555

SUBJECT:

COMANCHE PEAK' STEAM ELECTRIC STATION (CPSES)

DOCKET NOS. 50-445 AND 50-446 REQUEST FOR ADDITIONAL INFORMATION -

CONCERNING AS-INSTALLED BOLTS Gentlemen:

I In accordance with the recent discussions between the representatives:from TV Electric and the NRC. the following additional information regarding bolting material is provided.

TV Electric has performed further evaluation of the. bolting materials used at CPSES. The engineering evaluation is documented in TU= Electric document number CPSES-8901654 and-is available for NRC-staff review.

Si n ce rel y...

Y lbrtsh'

>f William J. Cahill. Jr..

i i

i 1

By:

Nhi Roger 'O. ' Wal ker Manager, Nuclear Licensing-

~

CBC/cbc

+

c - Mr. R. D. Martin, Region IV Resident Inspectors, CPSES (3)

. I j

s-l 9002020070 900126 PDR ADOCK 05000445 A

. PDC

- I P. O. Box 1002 Uten Rose, Texas 76043-1002 '

. k

[,

d,