ML20005G655

From kanterella
Jump to navigation Jump to search
Application for Amends to Licenses DPR-77 & DPR-79, Consisting of Tech Spec Change 90-05,revising Surveillance Requirement 4.6.5.1.b.2 to Extend Current 12-month Ice Weighing Interval to 18 Months
ML20005G655
Person / Time
Site: Sequoyah  
Issue date: 01/12/1990
From: Michael Ray
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20005G656 List:
References
NUDOCS 9001220071
Download: ML20005G655 (3)


Text

=b g-s p

TENNESSEE VALLEY AUTHORITY j

CHATTANOOGA. TENNESSEE 37401 T

0 SN 1578 Lookout Place i

V.

JAN 121990 TVA-SQN-TS-90-05 10 CFR 50.90

'i U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington. 0.C.

20555 Gentlemen:

i r

L In the Matter of

')

Docket Nos. 50-327 Tennessee Valley Authority

)

50-328 SEQUOYAH NUCLEAR PLANT (SQN) - TECHNICAL SPECIFICATION (TS) CHANGE 90-05 In accordance with 10 CFR 50.90, we are enclosing a requested amendment to i

licenses OPR-77 and DPR-79 to change the TSs of SQN Units 1 and 2.

The proposed change revises Surveillance Requirement (SR) 4.6.5.1.b.2 to extend the current li-month ice weighing interval to 18 months.

In addition TVA is proposing to lower the minimum TS ice-basket weight from 1,200 pounds to 1,155 pounds. This would reduce the overall ice weight from 2,333,100 pounds to 2,245,320 pounds. An-associated 12-month SR for ice condenser inlet doors (SR 4.6.5.3.1.b) is also being extended to coincide with the proposed 18-month interval for weighing ice.

The proposed TS change is identified in Enclosure 1.

The justification for the proposed TS change is provided in Enclosure 2.

A proposed determination of no significant hazards consideration performed pursuant to 10 CFR 50.92 is provided in Enclosure 3.

The revised containment analysis supporting this TS change is provided in Enclosure 4.

NRC issuance of the proposed change is requested by March 1, 1990, to preclude a Unit 2 ice weighing outage currently scheduled for March 5, 1990.

TVA will E

keep NRC project management informed of any schedule changes through routine

'i project review meet 1Ms.

4 9001220071 900112 gDR ADOCK 0500g-if7 0(

I l

An Equal opportunity Employer

e..

p U.S. Nuclear Regulatory Commission JAN 121990 t

Please direct questions concerning this issue to D. V. Goodin at l

(615).843-7734.

Very truly yours, TENNESSEE VALLEY AUTHORITY-Db A -

M. J. {ay,' Manager Licensing Project Management

. Swornj d subsc 4 ed before me i

  1. this /

day.of 990

>>lE b j.

f N51ary Public My Commission Expires M M i

Enclosures cc: See page 2 j

I q...

k1 i:

- q.

\\

.v; 4

k. -

n.

"i s U.S. Nuclear Regulatory v a ission JAN 121990 cc
Ms. S. C. Black, Assistant Director (Enclosures) for Projects TVA Projects Division U.S. Nuclear Regulatory Commission One White Flint, North 11555 Rockville Pike Rockville, Maryland 20852 l-Mr. B. A. Wilson, Assistant Director (Enclosures) for Inspection Programs TVA Projects Division t

U.S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 h

Atlanta, Georgia 30323 Mr. Michael H. Mobley,- Director Division of Radiological Health T.E.R.R.A. Building 150 9th Avenue, N Nashville, Tennessee 37203 NRC Resident Inspector (Enclosures)

Sequoyah Nuclear Plant 2600 Igou Ferry Road Soddy Daisy, Tennessee 37379 i

American Nuclear Insurers (Enclosures)

Attention:

Librarian i

The Exchange. Suite 245 270 Farmington Avenue Farmington, Connecticut 06032

>