Responds to NRC Re Violations Noted in IE Insp Repts 50-369/81-07 & 50-370/81-02.Corrective Actions: Const Procedure Implemented Defining Guidelines/Limitations to Be Used When Placing Temporary Scaffolding on Piping
ML20005B589
Person / Time
Site: McGuire, Mcguire  
Issue date: 05/12/1981
From: Parker W
DUKE POWER CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20005B581 List:
References
NUDOCS 8107080401
Download: ML20005B589 (2)


Text

. as L,

o DUKE POWER COMPm 7 0 ~ L Powra Duit.nixo

.,,/

402 Socin Citrucu Singer, CitAut.orir. N. C. 2s242

,.' ! ' ' '[ l $

0 h*. q $

wiwAu o. e4anca.a=

May 12, 1981 Vier petssCENT TELt#wohE A#tA 704 Stram peoowetion 3 7 3-40 e 3 Mr. James P. O'Reilly, Director U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, Suite 3100 Atlanta, Georgia, 30303.

Subject:

McGuire Nuclear Station Docket Nos. 50-369 and 50-370 Re: RII:WPK 50-369/81-07 50-370/81-02

Dear Mr. O'Reilly:

Please find attached a response to Infraction 370/81-02-01 which was identified in the above referenced Inspection Report.

I declare under penalty of perjury that the statements set forth herein are true and corr t to the best of my knowledge.

rytrulyyours,},

,/

4 '-< L b..

William O. Parker, Jr./

RWO/djs Attachment cc:

T. J. Donat Senior Resident Inspector McGuire Nuclear Station

)

~

hih70GO40i 81O624.

PDR ADOCK 05000069 C

PDR b-1 a

,....o.

McGUIRE NUCLEAR STATION NOTICE OF VIOLATION 370/81-02-01 A.

10 CFR 50, Appendix B, Criterion XIII as bnplemented by DPC Topical Report Duke 1-A, Section 17, Paragraph 17.1.13 requires measures be established to control storage of equipment to prevent damage.

Contrary to the above, on February 3-6, 1981, adequate measures were not established to control storage af equipment to prevent damage in that:

1.

Four examples of rigging from insta.lled safety-related piping were noted.

2.

Three examples of rigging lines impinging on cable trays

.,c cables in trays were noted.

3.

Approximately eight examples of material stored in cable trays con-taining cables were noted.

4.

Five examples of scaffolding supported safety-related piping were noted.

Response

The violation occurred due to a lack of adequate guide lines for installing temporary scaffolding on permanently installed components and a failure to properly execute the proper procedure involving housekeeping inspections for storage of installed equipment.

A constrtttion procedure has been implemented which defines the guidelines and limitations to be used when placing temporary scaffolding on piping, hangers, equipment, and any other components permanently installed in the field.

The procedure specifically states that:

A.

No scaffold shall be supported from Schedule 10 pipe.

B.

No scaffold shall place any loads on valve operators, cable trays and cables, hangers such as snubbers, struts, and movable type hangers.

C.

No scaffold shall be supported by a pipe with O.D. of less than 3".

and in gensral, scaffold shall never damage any permanently installed item.

The procedure involving house keeping inspections for storage of installed equipment has been reemphasized and the appropriate personnel have been notified of the importance of this procedure.

The station is currently in full compliance.