VraGINIA Ex.ncraIC AND Powna CoxPANY Racmasown,VamoxxxA naast June 26, 1981 Mr. Harold R. Denton, Director Serial No. 311A Office of Nuclear Reactor Regulation N0/DCW:acm Attn.

Mr. Robert A. Clark, Chief Docket No. 50-339 Operating Reactors Branch No. 3 License No. NPF-7 Division of Licensing U. S. Nuclear Regulatory Commission Washington, D. C.

20555 Gentlemen:

In our letter of May 22, 1981, Serial No. 311, we included an attachment, Table 4, in which we inadvertantly omicted the operability criteria used for pumps and valves.

Attached is a revised Table 4 for your review.

Please contact us if you have any further questions.

Very truly yours.

[

B. R. Sylvia Manager - Nuclear Operations and Maintenance Attachment ec:

Mr. James P. O'Reilly, Director Office'of Inspection and Enforcement Region II Atlanta, Georgia 30303 ey' (9

y T

"'UP 301981u 5' '* g p f; to f 8167010232-9

2,o.

TABLE 4 NORTH ANNA UNIT 2 MULTISTRUCTURE ARS OPERABILITY CRITERIA Operability review shall be performed for the Design Banis Earthquake (DBE) loadcase.

Non-linear static and dynamic analysis is permissible for operability review.

Maximum Allowable Stress in Pipe 2.4 S Class 2 & 3 ~ or 3.0S Class 1 h

(Note 1)

' Maximum Allowable Stress in Pipe Lesser of.7 Ultimate Stress or 1.2 Support & Base Plate Yield Stress (Note 2)

Maximum Allowable Bolt Tensile Ioad 1/2 Ultimate Pullout Load (Note 3)

Maximum Load on Snubber One-time Allowable Load Rating given in Grinnell Catalog PH-74 Maximum Load on Pumps and Valves Operability check in accordance with vendor requiremento NOTES:

1)

Based on Subsection NB-3600 (Class 1) and NC-3600 (Class 2 & 3) of the AMSE Section III Boiler & Pressure Vessel Code 1980.

2)

Based on Appendix F, Article F 1370 of the ASME Section III Boiler &

Pressure Vessel Code 1977 and Addenda up to summer 1979.

3)

Lased on I & E Bulletin 79-02.

I

_ _