05000281/LER-1981-035-03, /03L-0:on 810529,fuel Oil Transfer Pump 1B Suction valve,1-EE-14,was Found Closed.Caused by Personnel Error. Valve Opened

From kanterella
(Redirected from ML20005A355)
Jump to navigation Jump to search
/03L-0:on 810529,fuel Oil Transfer Pump 1B Suction valve,1-EE-14,was Found Closed.Caused by Personnel Error. Valve Opened
ML20005A355
Person / Time
Site: Surry 
Issue date: 06/26/1981
From: Joshua Wilson
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20005A348 List:
References
LER-81-035-03L-02, LER-81-35-3L-2, NUDOCS 8106300242
Download: ML20005A355 (2)


LER-1981-035, /03L-0:on 810529,fuel Oil Transfer Pump 1B Suction valve,1-EE-14,was Found Closed.Caused by Personnel Error. Valve Opened
Event date:
Report date:
2811981035R03 - NRC Website

text

NAc sORu su

' u.s. NucttAn nacutAToav comulss[ot.

m.m LICENSEE EVENT REFORT i

1 i,

OOldTROL ELOC3C 1 1

1 l

(PLEASE PAINT 03 TYPE ALL REQulAfD INFO *MATIONI n

C oI1llVlAlSJ,PlSI2l 0101 -l 01 01 01 01 01 -l Di o.j@ 41111 t i l 1 l@l 1

l@

6 e uctNsts :::t -

8 u;4NSEf*wMet"

S 2

u;1N56 Tv't JO 17 ;^T 68 00N 7 1evi!

,"c% iL )@l 015101010121 811 @l 01512191811 @l 01612161811 l@

6 so s2 DOCKET NvMs g m es str EvtNT oaTE 14 75 miromT oATg so IVENT DESCRIPTION AND PROBABLE CONSECuENCE5 b10

On May 29, 1981, fuel oil transfer pu!Ep 1B suction valve,1-EE-14, was found closed.

i o,3 i This is contrary to T.S. 3.16.A.5 and is reportable per T.S. 6.6.2.b.(2). The valve

o;3, y i

s;o,,,l had been closed for less than 24 hrs., and the redundant fuel oil path to No. 2 EDG j

i o,3, ; remained operable throughout the event. Therefore, the health and safety of the publig 1

o,,i ; were not affected.

I lo i? l !

i I

t o is i i so 7

se E

CD E SUS E

CDMPoNENT CCDE SUS $E 5

f lcisl 1 El El@ l A l@ l Bl@ lV l Al LlV l El Xlh l E l@ lD I@

7 8

8 to 11 12 13 1s is 23 SEQUENTIAL oCOUA RENCE REPORT mfV1830N Lf 8amo FVENTVEsa RE*0RT NC.

ccDE T*PE No.

@,Aj,';;g

!8 11 I l-l lo 13 is i 1/l 1013l lL l j _l lo l

_ 23 u

u 2

2.

2, 2.

=

2o 2,-

x EN A P NT Moum8 5 9 MITT PCm S.

.J Q

MA U$

mgm s;of ol of ol I Yl@

l Nl@

l Al@ lcl6I6l5lh Lxl@Lal@

LIJ@

Lz]@

I ao 43 42 42 4,

sa 24 s

as cAusE DESCRIPTION AND CORRECTIVE ACTIONS h

,, o i l The cause of this event was due to personnel error in that the valve was closed while ii4i; ; dewatering the fuel oil tanks as described in LER-81-033/03L-0. The corrective action; j

g g ; was to open the 'ralve.

g li t a l I 1

h ea t i I

.o t

o A

%PowtR UTutRSTATUS Di m

DISOCVEmY EESCm8PTioN NA l

l Bl@l Routine Sample

- l i5 1 [ g,j @ l 1 1 0 l 0 l @ l i1 s EnviTv CoSTeNT i

AMOUNT or ACTivtTv h l

,LocATroN or mEttAst h A

ttLEAsto or asLEAst NA l

NA l

It is l l Zl @ l Z l@l

?

8 9 to 11 as as go PERSONNEL EXPO $ vats NUMesm TYPt Dgs ms* Tion l i s t l l0 I o l 0 l@lz l@l NA l

'=

=

..m.

N,t' ~2.,

NUMete Dts mePTioN NA

,j is in I lo lo lo l@l

  • 9 11 12 gg Los3 C6 om oaMAct to FActuTv Twt des meetio%

NA l

l i ( e l l Zj@l 7

4 9 to gg 4

PueLic Tv NRC USE ONLY 45 tssure Desemention L:fol W hl NA l

ll t;Ill ; iigil3 7

t 9 to ss se sc :

J. L. Wilson (804) 357-3184 YE 08 **E* AREn

,m3;

  • * *D &

L

p='

'ATTACmfENT 1 (PAGE 10F 1)

SURRY POWER STATION, UNIT 2 DOCKET NO:

50-281 REPORT NO:

81-035/03L-0 EVENT DATE: 05-29-81 TITLE OF EVENT:

SUCTION VALVE. 1-EE-14. FOUND CLOSED

.l..

DESCRIPTION OF EVENT

On May 29, 1981, with Unit No. 2 at 100% power, fuel oil transfer pump 1B suction valve,1-EE-14, was fou..d to be closed, this is contrary to Tech. Spec. 3.16.A.5 and is reportable per Tech. Spec. 6.6.2.b.(2). Transfer pump 1B is one of two fuel oil pumps that supplies fuel oil to the #2 EDG wall tank. The suction valve had been closed for less than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, therefore in accordance with Tech. Spec.

No. 2 EDG remained ope rable throughout.this event.

2.-

PROBABLE CONSEQUENCES AND STATUS OF REDUNDANT EQUIPMENT:

The Emergency Diesel Generators provide power to vital equipment in the event of a loss of of f-site power. The redundant fuel oil flow path No. 2 EDG remained operable throughout this event. Therefore, the health and safety of the public were not affected.

3.

CAUSE

The valve had been closed while dewatering the fuel oil storage tanks at described in LER 81-033/03L-0.

4.

ImiEDIATE CORRECTIVE ACTION:

The suction > valve, 1-EE-14, was opened.

5.

SUBSEQUENT CORRECTIVE ACTION:

None required.

6.

ACTION TAKEN TO PREVENT RECURRENCE:

Operating personnel have been provided instructions regarding the control systems during abnormal situations.

7.-

GENERIC IMPLICATIONS:

None l

e L.