i L-I l

OPERATING DATA REPORT v

DOCKET NO.

50-286 DATE June 1, 1981 COMPLETED BY C. Connell TELEPHONE (914) 739-8200 (ext: 242)

OPERATING STATUS Notes

1. Unit Name: InrM an Pnine Nn_1 vnn1,,, pnunr plane

"#Y 1901

2. Reporting Period:
3. Licensed Thermal Power (MWt):

1025

4. Nameplate Rating (Gross MWe):

1013

5. Design Electrical Rating (Net MWe):

965

6. Maximum Depenlable Capacity (Gross MWe):

926

7. Mairnum Deper.dable Capacity (Net MWe):

891

8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report. Give Reasons:

None

9. Power Level To Which Restricted,If Any (Net MWe):

gn7 wn m-n.,4 m pnwn. e nen.)

10. Reasons For Restrictions. lf Any: Unit Load is restricted to the canacity of one uain transformer.

This Month Yr. to.Date Cumulative

11. Hours in Reporting Period 744 3,623 41.664
12. Number Of Hours Reactor Was Critical 737.8 2,191.5 28,941.5 - 2
13. Reactor Reserve Shutdown Hours
14. Hours Generator On-Line 726.7 2,134.9 27,838
15. Unit Reserve Shutdown Hours !
16. Gross Thermal Energy Generated (MWH) 1.194.909 a.97.ogo 7,

3no_7,o

17. Gross Electrical Energy Generated (MWH) 392.980 1.283.970 22.975.471
18. Net Electric I Energy Generated (MWH) 370,071 1,215,573 21,929,733
19. Unit Service Factor 97.7 58.9 66.8' 97.7 58.9 66.8 l
20. Unit Availability Factor l
21. Unit Capaci y Factor (Using MDC Net) -

55.8 37.7 59.1-51.5 34.8 54.5

22. Unit Capacity Factor (Using DER Net)
23. Unit Forceo Outage Rate 2.3 41.1

'1 F. Y

24. Shutdowns Scheduled Over Next 6 Months (Type. Date,and Duration of Each):

e.s 2 week shutdown in July to connect new main transformer.

25. If Shut Down At End Of Report Period. Estimated Date of Startup:

N/A

26. Units in Test Status IPrior to Commercial Operation):

Forecast Ac'hieve'd '

INITIA L CRITICALITY N/A N/A INITIA L ELECTRICITY N/A N/A COMM ERCIA L OPER ATION N/A N/A s

8106180 k @

gf773

~

t AVI.l(AGl. lialLY UNil l'OWI.it I.I. VEL DOCKET NO.

Sh25 Ino s an r.uint UNIT No 3 DATE June 1, 1981 COMPLETED BY - C. Connei1 TELEPllONE 914-739-8200 MONTII M3Y 1981 DAY AVERACE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe Net)

(MWe Net) 515 509 3

37 505 513 2

1S 3

'517 501 39 516 4

20 5

513 23 332 513 514 6_.

22 517 516 7

23 517 513 g

2-(

9 515 25 511 16 509 10 26 i

514 514 gg 7

i 517 516 t

12 2S 294 13 29 14 518 30 514 IS 518 33 515 16 518 INS 1 RUCTIONS On this format. list the aserage daily unit power leselin MWe. Net for each day in the repurong umnth. C 3:npute io the nearest whole megawatt.

L (9/77) y w-


r

-- -v'

-.-w

,--y r-u--t

.~

UNIT SilUTDOWNS AND POWER REDUCTIONS DOCKET NO. 50-286 UNIT NAME Indian Point #3-DATE Juna 1-19n1 COMPLETED BY C. Connell REPORT MONT1f May 1981 TELEPlf0NE 914-739-9200 Ext. 242

    • .2

~

3?

3

..Ek Licensee

,E-r, c 1, Cause & Corrective No.

Date g

gg

(;

jgy Esent F?

o?

Aoion to Report er LE 0

$U Prevent Recurrence'

$5 5

H 5 5 =@

v i

O 03 81 05 20 F

10.3 B

3 13/A EA Relay X Direct trip from Buchanan Substation D

caused by inadvertent relay operation while trouble shooting grounds.

04 81 05 29 F

7.0 B'

3 13/A EA Relay X Direct trip from Buchanan Substation caused by a transfer trip while per-forming relay checks.

I 2

3 4

F. Forced Reason:

Method:

Exhibit 7. Instructions S: Scheduled A-Equipment Failure (Explain) 1-Manual for Preparation of Data R. Maintenance of Test 2-Manual Scram.

Entry Sheets for Licensee C-Refueling 3-Automatic Scram.

Event Report (1.ER) File (NUREG-D-Regulatory Restriction 4 Other (Explain) 0161)

E-Operator Training & License Examination F Administrative 5

G-Operational Error (Explain)

Exhibii II-Same Source 19/77)

Il-Oiher (Explain)

MO!mlLY MAINTENANCE REPORT May 1981 Month

) RTE W.R.

EQUIPMENT MALFUNCTION CORRECTIVE ACTION

,-11 I-1923 CCR A/C Refrig. Compressor Dirty Cooling & Sensing Lines Cleaned Condensers.

>-11 I-1931 CCR A/C Compressors Dirty Cooling & Sensing Lines.

Cleaned Condensers i-ll I-1698 CCR A/C Dirty Cooling & Sensing Lines.

Cleaned Condensers Valve Seat Damaged Replaced Valve i-15 I-1975 CVCS Valve C-lO2 2-20 1-1739 SOV 1429/1430 Erractic Operation Cleaned / Lubricated Valves

o no n

i o

t i

t cA cen e

n v

o i

t C

c e

e s

r o

h r

1 o

t o

L 8

n C

9 o

1 d

M e

y n

a e

M t

hg iT mr n

a o

l i

A tc e

n l

T u

b R

f u

O l

o P

a r

E M

T R

4 I

Y t

R e

O l

G t

E u

T O

A s

C C

n I

e ts YL t

y n

S l

m e

nr m

t oe O

p i t M

i tl u

ci q

E eF t

ol ra P oc er r a ih

' C F

8 2

7 R.

0 4

W 1

C I

e t

9 a

7 D

9 9

r II

Summary of Operating Experience May 1981 Indian Point Unit 3 was synchronized to the bus for a total of 726.7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br />, producing a gross generation of 392,980 MWe for this reporting period.

The Unit experienced two trips during this reporting period.

The first trip, a direct trip from Buchanan substation, occurred on May 20 at 1909 hours0.0221 days <br />0.53 hours <br />0.00316 weeks <br />7.263745e-4 months <br />. The trip was caused by inadvertent reIty opera-tion while technicians were trouble shooting grounds in the associated relay wiring. The Unit was returned to service at 0527 hours0.0061 days <br />0.146 hours <br />8.713624e-4 weeks <br />2.005235e-4 months <br /> on May 21.

The second trip which was also a direct trip from Buchanan substation, occurred at 0100 hours0.00116 days <br />0.0278 hours <br />1.653439e-4 weeks <br />3.805e-5 months <br /> on May 29.

The trip was traced to misoperation while technicians were performing relay checks on 345 KV feeder Y88.

The unit was promptly returned to service at 0800 hours0.00926 days <br />0.222 hours <br />0.00132 weeks <br />3.044e-4 months <br /> on the same day.

(-