05000331/LER-1981-020, Forwards LER 81-020/01T-0

From kanterella
(Redirected from ML20004F144)
Jump to navigation Jump to search
Forwards LER 81-020/01T-0
ML20004F144
Person / Time
Site: Duane Arnold 
Issue date: 06/10/1981
From: Mineck D
IES UTILITIES INC., (FORMERLY IOWA ELECTRIC LIGHT
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20004F145 List:
References
DAEC-81-340, NUDOCS 8106160551
Download: ML20004F144 (1)


LER-1981-020, Forwards LER 81-020/01T-0
Event date:
Report date:
3311981020R00 - NRC Website

text

_ _ _ _ - _ _ _ _ _ _ _ _ _

l I-i Iowa Electric Light and Power Company

' ~ * !/,'y '

June 10, 1981 c

DAEC-81-340 E.

b s

.:O.

\\# 3 W, e,

['

Mr. James G.

Keppler, Director e

Office of Inspection and Enforcement A

U. S. Nuclear Regulatory Commission - Region III (6/,

/

b '. 4 ] G[' 1/

799 Roosevelt Road Glen Ellyn, IL 60137

Subject:

Licensee Event Report No. 81-20 (14 day)

File:

A-ll8a

Dear Mr. Keppler:

In accordance with Appendix A to Operating License DPR-49, Technical Specifications and Bases for Duane Arnold Energy Center and Regulatory Guide 10.1, please find attached a copy of the suhject Licensee Event Report.

(Total of 3 copies transmitted).

Very truly yeurs, l4A./

W Daniel L.

Mineck Chief Engineer Duane Arnold Energy Center Docket 50-331 attachment DLM/MSR/pl cc:

Director, Office of Inspection and Enforcement (40)

U. S. Nuclear Regulatory Commission Washington, D.

C.

20555 Director, Management Information and Program Control (3)

').

S. Nuclear Regulatory Commission Washington, D.

C.

20555 U. S. Nuclear Regulatory Commission t

c/o Document Management Branch Washington, D. C.

20555 NRC Resident Inspector - DAEC

~ /. to tgg 810 6 i 6 o G $,,,,. w,,,a1 n,c,g, n.,,,,,

,,o,u,s.us n,s.se n.,1,ia,.]mv., suam. as vus.sas