Responds to IE Bulletin 79-14, Seismic Analyses for As- Built Safety-Related Piping Sys. Required Verification/Insp Has Been Completed.Three Nonconformances Were Identified Invalidating Seismic Analysis for Piping Sys.Nrc Notified
ML20004D154
Person / Time
Site: San Onofre 
Issue date: 06/02/1981
From: Haynes J
SOUTHERN CALIFORNIA EDISON CO.
To: Engelken R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
IEB-79-14, NUDOCS 8106080479
Download: ML20004D154 (3)


Text

.2 Southern California Edison Company F

  • O BOX 300 2 2 44 W ALNUT GROVE AVENUE ROSEMEAC CALIFORNI A 91770

?

- py r.

ta m ~es au -o -

,9;.

an. m-m... o,

c a.. o,... r.o June 2, 1981 m,

9, JUN 0 5198I 5 by.

U. S. Nuclear Regulatory Commission u.a.emm mwost +!

^/

Office of Inspection and Enforcement

/#g @ J i.'

Region V 1990 North Califoraia Boulevard

' '4 Suite 202, Walnut Creek Plaza Walnut Creek, California 94596 Attenti on: Mr. R. H. Engelken, Director DOCKET NO. 50-206 SAN ON0FRE - UNIT 1

Dear Sir:

In response to IE Bulletin No. 79-14, " Seismic Analyses for As-Built Safety-Related Piping Systems," our January 14, 1980 letter prc5vided the results of the verificati'On/ inspection of accessible safety-related piping systems, except for a random selection of insulated support details, as described in our August 10, 1979 and September 10, 1979 letters. We indicated that those piping systems where insulation will be removed for certain support details would be inspected consistent with the inspections of inaccessible safety-related pip'ing systems (i.e., prior to or during the current outage) as described in our September 10, 1979 letter.

The purpose of this letter is to advise you that de have completed the required verification / inspection of (1) the random selection of insulated support details on accessible safety-related piping systems as described in our January 14, 1980 letter, and (2) tne inaccessiole safety-related piping systems as described in our August 10, 1979 and September 10, 1979 letters.

Based on the results of the verification / inspection, three nonconformances were icentifiea invalidating the seismic analysis for the piping systems.

In 9:ch case, your of fice was pronptly notified of tne nonconformances in accordance with the bulletin and our Technical Specifications witn followup letters describing the details surrounding tne nonconformance and the action taken to correct the nonconformances.

15l@l s

IE -u 080Q

4-

, 4 Mr. R. H. Engelken, Director June 2, 1981 The enclosure to this letter provides a list of piping systems verified / inspected where nonconfo'rmances were identified and a summary i

description of the actions taken to correct the nonconformances. With the submittal of this letter, we have completed the actions required by IE Bulletin No. 79-14.

As discussed in our January 14, 1980 letter relative to accessible safety-related piping systems, we conducted a field veritication/ inspection for all inaccessible safety-related piping systems rather than rely on available certified, as-built drawings.

In addition, the insulation was removed from all inaccessible safety-related piping systems, where necessary, to conduct the verification / inspection of support details.

If you have any questions or, desire further information concerning this matter, please contact me.

Very truly yours, bi QM Enclosure c'c : Directur, Of fic,e of Inspection and Enforcement, Headquarters /

L. Miller, USNRC Resident inspector

ENCLOSURE

SUMMARY

OESCRIPTION OF ACTIONS TAKEN TO CORRECT NONCONFORMANCE IN RESPONSE T0 IE BULLETIN NO. 79-14

)

SAN ON0FRE UNIT 1 Piping System Corrective Action Residual Heat Removal Letters dated May 12, 1980 (Line3009-2"-A) and May 22, 1980 to NRC described missing U-boit support and corrective action to install U-bolt.

Safety Injection Letters dated June 12, 1980 and (Lines 6006-6"-1501R July 1,1980 to NRC described a and 6007-6"-1501R) damaged pipe guide and an inade-quately designed and constructed pipe guide and corrective action to repair the damaged pipe guide and modify the inadequately designed and constructed pipe guide.

Feedwater Letters dated February 2,1981 (Line 392-10"'EG) and February 17,1961 to NRC described missing bolts from anchor supports and corrective actions to jnstall bolts, m

.