Requests NRC Approval to Proceed W/Normal Form Waste Shipments in Model 1600 Until 810701.Development of Process Sys Providing Enhanced Containment & Immobilization of Normal Form Contents Is Underway
ML20004C926
Person / Time
Site: 07109044
Issue date: 02/20/1981
From: Cunningham G
GENERAL ELECTRIC CO.
To: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
References
18521, NUDOCS 8106080047
Download: ML20004C926 (3)


Text

.c gf-vow NUCLEAR ENERGY ENER AL ! j ELECTRIC p[

p s,,

U ENGINEERING i 9 M}

Mi 8

C COMPANY, P.O. BOX 460. PLEASANTON, CALIFORNIA 94566 DIVISION

$ opf ELC

'.Y. 5 5.

h. '..'.

Mr. C. E. MacDonald, Chief 5

-.. n g...

9e n

s...

q (d

~

/

Transportation Certification Branch Division of Fuel Cycle and Material Safe f jgo 3 L U. S. Nuclear Regulatory Commission Duro O

%c Washington, D. C.,

20555

'g JU// O Raf: Certificate of Compliance No. 904 l19Bf, bg

\\?,

% sj**

Dear Mr. MacDonald:

\\

%g'*k Q

b Certificate of Compliance No. 9044 require ve material be in g

the form of fuel rods or plates, fuel assemb iated solid metal hardware, or meeting the special form requirements of 10CFR71.4(o). Accord-ingly, General Electric-VNC is developing methods to provide enhanced con-tainment and immobilization of normal form contents by encapsulation and/or impregnation.

Our best schedule estimate for a process system to impregnate and immobilize this normal form waste would have the system operational at the end of June, 1981. Details of this system which uses a cement type grout to solidify and bond the waste contents in a modified dot 17H drum have been discussed with your staff, and preliminary concurrence has been reached on methods of dem-onstrating compliance with 10CFR71.

Although good progress is being made on the new process system, the Building 102 hot cell complex has developed an accumulation of waste material which will shortly imperil continued operation of that complex. The facility gen-erates approximately eleven cubic feet of normal form waste each month (one load for the G.E. Model 1600 shipping container). No waste shipments have been made since August,1980.

Accordingly, GE-VNC requests permission to proceed with nonnal form waste shipments in the G.E. Model 1600 container until July 1,1981, subject to the following restrictions.

The waste will be placed in an inner container which will be either a standard dot 17H metal drum or an extended 17H type drum. Shoring will be installed, as required, to restrict movement of the standard drum in the cask cavity (the extended drum is approximately 51 inches in length by 24 inches in diameter). The drums are equipped with gaskets and will be sealed. All of the drums hage been {eak-tested and have demonstrated a leak rate of less than 1 x 10- atm-cm /sec. 18521 81060800 6 O

,.n' GENER AL h ELECTRIC

' Mr. C. E. MacDonald February 20, 1981 The type of waste to be shipped is general hot cell waste and includes equipment, metal tubing, solid byproduct materials (e.g., Co-60, IR-192, etc.) in 2-R type containers, compacted wastes (paper, wipes, etc.), melted plastics (in metal cans), salts from neutralized hcl, and glassware. The chief contaminants are Co-60, Cs-137, and mixed fission products. No trans-uranics are present.

A check for the $150.00 fee will be forwarded under separate cover.

()7. f.'

G. E. Cunningham Senior Licensing Engineer

/jp C

18521

o

~

~

Docket No.

William O. Miller License Fee Management Branch Office of Administration MATERIALS TRANSPORTATION APPROVAL CLA53IFICATI0tl Applicant:

b5 Apor-

"3:

fo f/ I Fee Category // 8 App'

_.i Dated:

' - t o -f/

Received: 1.25-f/

l Applicant's Classification:

et J m Q 5,,,i The abo.ve aoplication for amendment has been revie,.ed by the NMss Transportation Branch, in accordance with Section 170.31, and is classified as follows:

1.

Amendments to Acorovals in Fee Catacortes IIA throuch 11E (a)

Major.

(b)

Minor

/ dministrative (c)

A 2

Justification for reclassificatich:

I l

1 3.

The application was filed (a) cursuant to written NRC request and the amendment is being issued for the convenience of the Commission, or (b)

Other (State reason):

I i

Signature: R t/ C. '..,,.. d.

l Tran portation Branch, !".55 Date:

3/t/7/

/752i

.