ML20004C253

From kanterella
Jump to navigation Jump to search
Forwards Updated LER 81-047/03L-1
Date released: 01/18/2020 Download: ML20004C253


Updated LER 81-047/03L-1:on 810422:during Local Leak Rate Testing,Discovered Leakage in Primary Containment Isolation valves,1-CAC-V7,V9,V15,V16 & V17.Caused by Corroded Valve Discs.Valves Replaced W/Corrosion Resistant Discs
ML20004C254
Person / Time
Site: Brunswick Duke Energy icon.png
Issue date: 05/28/1981
From: Pastva M
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20004C254 (1)
Forwards Updated LER 81-047/03L-1
ML20004C252
Person / Time
Site: Brunswick Duke Energy icon.png
Issue date: 05/28/1981
From: Dietz C
CAROLINA POWER & LIGHT CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20004C252 (1)