Forwards ACRS Questions Raised at Fluid Dynamics Subcommittee 810428-29 Meeting.Response Requested within 30 Days
ML20004B816
Person / Time
Issue date: 05/20/1981
From: Kniel K
Office of Nuclear Reactor Regulation
To: Chau H
MARK II OWNERS GROUP
References
ACRS-GENERAL, NUDOCS 8106010087
Download: ML20004B816 (3)


Text

$

pitou

~

[o UNITED STATES 4.g g( '( g 8

g NUCLEAR REGULATORY COMMISSION g

j..E WASHINGTON, D. C. 20555

%, '.O May 20, 1981 o

r Dr. 4. Chau, Chairman Mari. II Owners Group Long Island Lighting Company 175 E. Old Country Road Hicksville, New York 11801

Dear Dr. Chau:

Two questions were raised by the ACRS at the April 28, 29,1981 Fluid Dynamics Subcommittee meeting. These questions are enclosed.

We are asking that you provide the staff with your response within 30 days of receipt of this letter in order that we may respond to the ACRS.

Contact Clifford Anderson, (301) 492-9424 should you have any questions about this request.

Sincerely, l

/

Karl Kniel, Chief Generic Issues Branch Division of Safety Technology

Enclosure:

Questions c

v r

/,

blJ b

g 2

NAY 2 81981 #

I I2 i agron u.s.

Q

/

4el'-

g l

l l

l 1

l l

l BI 06 010 Qg

Enclosure ACRS INF0kMATION REQUEST MARK II P00L DYNAMIC LOADS The ACRS questions relate to potential pool by-pass fmm stuck open wetwell-to-drywell vacuum breakers and by-pass thru ruptured main vent downcomers.

1.

The Mark II containment wetwell/drywell vacuum breakers may be called upon to function repeatedly during intermittent steam condensation phenomena.

Failure of a vacuum breaker ~ to close during this time could result in pool bypass, thus jeopardizing the integrity of the containment.

Provide valve service information for the range of wetwell/drywell vacuum breaker operation under pool dynamic loading. This information should be sufficient to describe the opening and closing characteristics of these valves during intermittent steam condensation.

2.

The steam chugging loads proposed as design loads by the Mark II Gwner's Group for containment evaluation were developed to represent limiting conditions during a postulated loss-of-coolant accident. As such, they are applied one time to the downcomers. The Mark II Owner's l

have indicated that chugging induced fatigue loads are insignificant due l

to the large reduction in loads with time and the relatively low number of fatigue cycles. Additional information is needed to evaluate this position. Provide the following information for a typical plant.

For l

l a range of break sizes, estimate the number of " Pool Chug" cycles.

i 1

This analysis should be extended sufficiently in time to include operation of the emergency core cooling system and the associated vessel steaming rates.

If there exists a vent flow threshold below which the chugging loads are insignificant, this should be clearly identified in the analysis.

l The information should be provided for both the chugging downcomer lateral loads and the pool chugging loads.

1 l

L