ML20004B650

From kanterella
Jump to navigation Jump to search
Forwards LER 81-044/03L-0
Date released: 01/18/2020 Download: ML20004B650


LER 81-044/03L-0:on 810504,HPCI Min Flow Valve Would Not Operate After Being Closed W/Control Switch During Operability Test.Caused by Pressure Switch HPCI Pump Discharge Failing W/Valve Closing.Bourdon Tube Replaced
ML20004B652
Person / Time
Site: Hatch 
Issue date: 05/21/1981
From: Coggin C
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20004B652 (2)
Forwards LER 81-044/03L-0
ML20004B649
Person / Time
Site: Hatch 
Issue date: 05/21/1981
From: Manry M
GEORGIA POWER CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20004B649 (1)