Text
]{ff 7
MAY 01 TAl 1
7 4
7
/
eP DISTRIBUTI0ft:
TERA HSilver IE-3 Docket File fiSIC RJacobs
!CRS-10 flRC PDR ORB #4 Rdg DDilanni Gray File L PDR DEisenhut EHylton BSnyder g ;g Docket No. 50-289 JStolz RCapra f<utchin - -TMI Site Pouch
\\
4 t['Q[A OELD RVollmer AEOD RMattson Y,0 6 ;ggg/-/J Mr. Henry D. Hukill, Vice President and Director - THI-l g
"4 Metropolitan Edison Cocpany Q'b f5 P. O. Box 480 niddletown, Pennsylvania 17057~
/
//
~g
Dear Mr. Hukill:
SUBJECT:
TMI-1 RESTART ENVIR0fjMENTAL QUALIFICATION As part of our continuing review of the environmental qualification of equipment in TMI-1, we request that you provide the following infor-mation by May 15, 1981.
1.
List all of the essential systems and equipment required to bring the plant to a safe shutdown following a postulated loss of main feedwater transient and accompanying small-break LOCA. You snould examine.a break size of approximately 0.5 ft.2;and a break size less than or equal to 0.01 ft.Z to obtain the full spectrum of.small breaks. The analyses should confider the worst single failure.in addition to the loss of off-site power.
2.
Define the parameters with the supporting bases of.the environment generated by the accident in 1. above.in containment and in the auxiliary building.
3.
For equipment identified in 1. above, provide all of the environmental qualification infonnation needed to assure its operability under the environ-mental conditions described in 2. above.. App.licable infonnation provided in your response to IE Bulletin 79-012 may be cited.
Sincerely.
Original signed by 8105110g h John F. Stolz, Chief operating Reacton Branc3,4 f
Division of Licensing l
cc:
See next 3 page.:
so
@l e *35
- See previous 318 for concurrences.
2" ::) 0RBd4;DL..... 0RB14:.DL.
.C-0RBy.:DL. '.~n :r DJ D:DE
.D:DSI 4
.ss~ty HSil ver/cb RJacobs
- JStolz*
- T' a(
,MCuu. M...
' R7o T1Hb?*'
- RMattson *"
i
- ..cp 5 [ /8'1"
'd/5E/Ul"
[d/55/8I
- { /5i' 5[
l
'4 23/01' f4'/29/81~
sa: :o re : e: s w.::.:
OFFICIAL RECOR D COPY
Metropolitan Edison Company ccw/ enclosure (s):
Mr. Marvin I. Lewis Dr. Walter H. Jordan 6504 Bradford Terrace 881 W. Outer Drive Philadelphia, Pennsylvania 19149 Oak Ridge, Tennessee 37830 Waltar W. Cohen, Consumer Advocate Dr. Linda W. Little Departmsst of Justice 3000 Hermitage Drive Strawberry Square,14th Floor Raleigh, North Carolina 27612 Harrisburg, Pssnsylvania 17127 Ms. Gail P. Bradford Robert L. Knupp, Esq.
Anti-Nuclear Group Representing Assistant Solicitor York Knupp and Andrews 245 W. Philadelphia Street P. O. Dox P York, Pennsylvania 17404 407 N. Front Street Harrisburg, Pennsylvania 17108 John Levin, Esq.
Pennsylvania Public Utilities Comm.
John E. Minnich, Chairman Box 3265 Dauphin Co. Board of Commissioners Harrisburg, Pennsylvania 17120 Dauphin Cotnty Courthouse Front and Market Streets Jordan D. Cunningham, Esq.
Harrisburg, Pennsylvania 17101 Fox, Farr and Cunningham 2320 North 2nd Street
- Atomic Safety and Licensing Appeal Board Harrisburg, Pennsylvania 17110 U.S. Nuclear Regulatory Commission Washington, D. C.
20555 Ms. Louise Bradford TMIA
- Atomic Safety and Licensing Board Panel 1011 Green Street U.S. Nuclear Regulatory Commission Harrisburg, Pennsylvania 17102 Washington, D. C.
20555 Ms. Marjorie M. Aamodt
- Docketing and Service Section R.D. #5 U.S. Nuclear Regulatory Commission Coatesville, Pennsylvania 19320 Washington, D. C.
20555 Ms. Karen Sheldon Robert Q. Pollard Sheldon, Harmon & Weiss 609 Montpelier Street 1725 I Street, N.W. - Suite 506 Baltimore, Maryland 21218 Washington, D. C.
20006 Chauncey Kepford Earl B. Hoffman Judith H. Johnsrud Dauphin County Commissioner' Environmental Coalition on Nuclear Power Dauphin County Courthouse 433 Orlando Avenue Front and Market Streets State College, Pennsylvania 16801 Harrisburg, Pennsylvania 17101 Ms. Frieda Berryhill, Chairman Ms. Ellen R. Weiss, Esq.
Coalition for Nuclear Power Plant Sheldon, Harmon & Weiss Postponement 1725 I Street, N.W.
2610 Grendon Drive Suite 506 Wilmington, Delaware 19808 Washington, D. C.
20006 Mrs. Rhoda D. Carr Mr. Steven C. Sholly I
1402 Marene Drive I!nion of Concerned Scientists Harrisburg, Pennsylvania 17109 1725 I Street, N. W., Suite 601 Washington, DC 20006
~.
Metropolitan Edison Company Mr. Thomas Gerusky Ms. Jane Lee Bureau of Radiation Protection R.D. 3, Box 3521 Department of Environmental Resources Etters, Pennsylvania 17319 P. O. Box 2063 Harrisburg, Pennsylvania 17120 Karin W. Carter, Esq.
505 Executive House P. O. Box 2357 Mr. G. P. Miller Harrisburg, Pennsylvania 17120 Mr. R. R. Wilson Metropolitan Edison Company Honorable Mark Cohen P. O. Box 480 512 D-3 Main Capital Building Middletown, Pennsylvania 17057 Harrisburg, Pennsylvania 17120 G. F. Trowbridge, Esq.
Dauphin County Office Emergency Shaw, Pittman, Potts & Trowbridge Preparedness 1800 M Street, N.W.
Court House, Room 7 Washington, D. C.
20036 Front & Market Streets Harrisburg, Pennsylvania 17101 Mr. E. G. Wallace Licensing Manager Department of Environmental Resources GPU Service Corporation ATTN: Director, Office of Radiological 100 Interpace Parkway Health Parsippany, New Jersey 07054 P. O. Box 2063 Harrisburg, Penns: Ivania 17105 Mr. R. W. Conrad Vice President, Generation Director, Criteri and Standards-Pennsylvania Electric Company Division 1007 Broad Street Office of Radiati 1 Proc;rans ( ANR-460)
Jonnstown, Pennsylvania 15907 U. S. Environmen: ' Protection Agency Washington, D. C.
20460 Ms. Vi rginia Southard, Chai rman Citizens for a Safe Environment 252 Walton Street Lsroyne, Pennsylvania 17043 Mr. Robert B. Bors um Babcock & Wilcox 30/arnment Publications Section Nuclear Power Generation Division State Library of Pennsylvania Suite 420, 7735 Old Georcetown Road 3 0.t 1601 (Education Building)
Bethesda, Maryland 20014 harris:)urg, Pennsylvania 17125
- Ivan W. Smith, Esq.
Mr. David D. Maxwell, Chairman Atcmic Safety & Licensing Board Panel Board of Supervisers U.S. Nuclear Regulatory Commission Londonderry Township Washington, D. C.
20555 RF,3dl - Geyers Church Raod Middletown, Pennsylvania 17057 Ms. Kathy McCaughin Three Mile Island Alert, Inc.
U. S. Environner.tal Protection Agency 23 South 21st street Region III Office Harrisburg, Pennsylvania 17104 AU N: EIS COORDINATOR Curtis Building (Sixth Floor)
Mr. L. W. Harding 6:n and Walnut Streets Supervisor of Licensing Oniladelphia, Pennsylvania 19106 Metropolitan Edison Company P. O. Box 480
't. J. G. Herbein Middletown, Pennsylvania 17057 Director, Nuclear Assurance Fe:ropclitan Edison Company P. 0. Box 480 Middletown, PA 17057
. o Metropolitan Edison Company Mr. R. J. Toole Allen R. Carter, Chairman Manager, TMI-l Joint Legislative Comittee on Energy Metropolitan Edispn Company P. O. Box 142 P. O. Box 480 Suite 513 Middletown, Pennsylvania 17057 Senate Gressette Building Columbia, South Carolina 29202 Mr. W. E. Potts Radiological Controls Manager, TMI-l Daniel M. Pell, Esq.
Metropolitan Edison Company ANGRY P. O. Box 480 32 South Beaver Street Middletcwn, Pennsylvania 17057 York, Pennsylvania '17401 Mr. I. R. Finfrock, Jr.
William S. Jordan III, Esq.
Jersey Central Power & Light Company Harmon & Weiss Madison Avenue at Punch Bowl Raod 1725 I Street, NW, Suite 5C6 Morristown, New Jersey 07950 Washington, DC 20006 J. B. Liebeman, Esq.
General Counsel Berlock Israel A ' iber an Federal Emergency Management Agency 25 Broadway ATTN: Docket Clerk New York, NY 10004 1725 I Street, NW Washington, DC 20472 Mr. J. J. Colitz N
d*
Plant Engineering Manager, TMI-l S e Perations TMI-2 Metropolitan Edison Company P. O. Box 480 d,etropolitan Edison compar.y Middletown, Pennsylvania 17057 P. O. Box 480 Middletown, Pennsylvania 17057 York College of Pennsylvania Mr.
- t. D. Fuller Country Club Road York, Pennsylvania 17405 TMI-2 Licensing Supervisor Metropolitan Edison Company Mr. G. K. Hovey P. O. Box 480 Director, TMI-2 Middletown, Pennsylvania 17057 l
Metropolitan Edison Company P. O. Box 480 Mr. Donald R. Haverkamp Middletown, Pennsylvania 17057 Senior Resident Inspector (Ti!I-1)
U.S.N.R.C.
Mr. B. Elam P. O. Box 311 l
Manager, Plant Engineering, Unit 2 Middletown, Pennsylvania 17057 Metropolitan Edison Comoany P. O. Box 480 j
Middletown, Pennsylvania 17057 l
Mr. Richard Roberts The Patriot 812 Market Street l
Harrisburg, Pennsylvania 17105 Governor's Office of State Planning l
Mr. R. W. Heward and Cevelopment j
Manager, Radiological Control, Unit 2 ATTN: Coordinator, Pennsylvania Metropolitan Edison Company State Clearinghouse l
P. O. Box 480 P. O. Box 1323 l
Middletown, Pennsylvania 17057 Harrisburg, Pennsylvania 17120 l
P00R ORIGINAL
-.