APPLICANT'S CORRECTIONS TO TRANSCRIPT OF NRC HEARINGS CONDUCTED ON APRIL 20-21, 1981 Ignoring some scattered, obvious typographical errors, the only possibly significant corrections which need to be made are shown below.
Page Line Traascript Correction 742 2
delete " hold" 745 22
" assist" should be " assistance" 766 2
"16" should be "17" 8
"16" should be "17" 795 10 "they" should be "there" 006 17 "120" should be "100" 820 3
"to" should be "plus" 825 3
" rods" should be " racks" 828 12
" notice" should be " amendment" 835 17
" abnormal" should be " normal" 852 2
delete "at" 3
" seized" should be " sees" 869 2
"both" should be " bowed" 8106070 3bY
Page Line Transcript Correction 879 3
"and" should be "an" 881 18 "in" should be "on" 885 25
" fuel channel assembly" should be " fuel assembly" 914 10
" pond" should be " pools" 915 8
delete "in" 916 1
"1,000-ton" should be "1,000-pound" 15 After the end of the question, "Would it not, in fact, take four tests of each location by mandrel rather than two?" the witness' answer begins: "A:
If you wanted it -- I suppose if.
958 4
add " greater" after " times" 960 23
" cams" should be " cans" 25
" cams" should be " cans" 987 7
add "will" before "come in,"
988 14
" enumerate" should be " eliminate" Mr. Shaw's testimony has not been bound in the record and it should be.