ML20003H256

From kanterella
Jump to navigation Jump to search
Supplemental Deficiency Rept,Initially Reported 801014,re Embedded Plates W/O Heat Traceability.Util Has Not Completed Corrective Actions.Final Response Will Be Submitted by 810529
ML20003H256
Person / Time
Site: Phipps Bend Tennessee Valley Authority icon.png
Issue date: 05/01/1981
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
NCR-PBNP-156, NUDOCS 8105050430
Download: ML20003H256 (1)


Text

. . , . .

400 Chestnut Street Tower II May 1, 1981

-Q j [. ,\

t.s o

,Q f?

Yi n[re$.s u -

Mr. James P. O'Reilly, Director Office of Inspection and Enforcement }y,>,'f f

U.S. Nuclear Regulatory Comtission '"

Region II - Suite 3100 101 Marietta Street Atlanta, Georgia 30303

Dear Mr. O'Reilly:

PHIPPS BEND WCLEAR PLANT UNIT 1 - REPORTABLE DEFICIE CY - D' Rum PIATES WIT 90(R HEAT TRACEABILITY (NCR PBNP-156)

Initial notification of the subject deficiency was made to N O CIE Region II Inspector R. W. Wright on October 14, 1980. 'Ihe final report was subnitted on January 13, 1981. A supplemental response was subnitted on March 2,1981, which attenpted to more accurately describe the cause and necessary corrective actions to prevent recurrence. 'Ihese actions were to have already been ccznpleted by the date of the supplemental response. In a telephone conversation with P. A. Taylor of your staff on March 11, 1981, we stated that the corrective actions mentioned above had not been ocznpleted as previously indicated. During this call, 'IVA agreed to provide an additional resconse which would clarify this n!tuation and accurately address the necessary actions to prevent recurrence. As discussed with F. S. Cantrell of your staff on May 1,1981, 'IVA has yet to cx2nplete these corrective actions and will, i therefore, sutr.it a final response on or before Mr/ 29, 1981.

Very truly yours, TEMESSEE VALLEY AUIHORITY L. M. Mills, Par'.oer Nuclear Regulatic.1 and Safety cc: Mr. Victor Stello, Director Office of Inspection and Enforcem?nt U.S. Nuclear Regulatory Ccrytissien 3 Washington, DC 20555 l lO

\

l

8105050 W b

- - _ - - .--