Construction Testing DATE APPf0VED
/u l.!!bu b'25~~78 AUTHORIZED FOR USE DATE EFFECTIVE DATE:
JULY - 1 1978 6
0UALITY ASSURANCE PROGRM FOR USE, MAINTENANCE AND REPAIR OF SHIPPING CONTAINERS FOR RADI0 ACTIVE MATERIAL GEO CONSTRUCTION TESTING 1118 Chess Drive Foster City, California 94404 Wherever the words
" Peabody Testing /X-Ray Engineering Co." or "X-Ray Engineering Co." appears in this Program, it shall hereafter mean "GEO Construction Testing".
j
Reference:
10CFR71 l
l 0
Original Issue SEr 6/7t/vo A
Revised Paragraph 7.0 TWC B/23/79 t/06/31 Revision - Name Change ONLY TWC t
i 5305 8E{g DES::R!m 0M M
OT 8104300163
~ ~. -..... - -
1.0 ORGMIZATION 1
2.0 QUALITY ASSURMCE PROGRN4 1
3.0 COCUMENT CONTROL
'l 4.0 HANDLING, STORAGE MD SHIPPING 2
5.0 INSPECTIONS. TEST MD OPERATING STATUS 2
6.0 QUALITY ~ ASSURANCE RECORDS 2
7.0 AUDITS -
2 3
Organization Qiart Attachment Shipping Container Inspection (yearly) form Radioactive Material Transfer Report (Figure 3)
Management Audit - Radiation Safety Officer 1
$' PROGRAM FOR USE, MAINTENMCE MD PIPAIR OF i.
kHIPPING CONTAINERS FOR RADI0 ACTIVE MATERIAL A
--a w-d
.,.y e - - - - ~ - e-
,,.-,+.
- +
e e--.-m
- Fa&/ esn]
T 1.] OE3%3IZATICN The final responsibility for the Quality Assurance Program for Part 71 re-quirerents rests with Peabcdy Testing /X-Ray Engineering Cercany. Design and fabrienien of radioactive material shipping packages shall net be cen-ducted under this Quality Assurance Program. The Quality Assurance Program is, implemented using tne following organization:
a.
The Radiaticn Safety Officer is respcnsible for overall ad=inistratien of the Program, training and certification, docurent centrol, and auditing.
b.
Radiograchers are responsible fo.' handling, storing, shipping, inspec-tien, test, operating status and record keeping.
2.0 CUALITY A55URx4CE PROGFAM The management of Peabody Testing /X-Ray Engineering Cerr.any establishes and implements this Quality Assurance Program. Training for all QA functions, prior to engagement in these functions, is required according to written p recedures. QA Progran revisions will be =ade according to written proce-dures with management approval. The QA Pr gram will ensure that all defined QC procedures, engineering precedures, and specific previsiens of the package design approval are satisfied. The QA Program will erphasize cen-trol of the characteristics of the package which are critical to safety.
The Radiatien Safety Offiser shall assure that all radicactive caterial shipping packages are designed and canufactured under a Quality Assurance Program approved by the Nuclear Regulatory Cec =ission for all packages de-signed or fabricated after July 1,1978. This requirerent can be satisfied by receiving a certification to this effect frca the canufacturer.
Written procedures and instructicns for i=plementing the Quality Assurance Program are centained in the Radiation Safety Progra=.
3.0 CCCLHENT CCNTROL All dccuments related to a specific shipping package will be centrolled through the use of written procedures. All document changes will be per-fenned according to written procedures approved by management.
The Radiation Safety Officer shall insure that all QA functions are con-ducted in accordance with the latest applicaole changes to these documencs.
NC.
' TITLE
' R E V.
PAGE OA PROG;AM FOR "", MAINTENNiCE AND REP AIR OF SHIP?ING CONTA, M.S FOR RMICACTIVE P.ATERIAL A
1 of 4 e
'"mY g,
4.0 FANDLING, STOPAGE AND SHIPPING Written safety procedures concerning the handling, storage, and shipping of packages for certain special form radioactive material will be followed.
Shipments will not be made unless all tests, certifications, acceptances, and final inspections have been completed. Work instructions will be pro-vided for handling, storage, and shipping operations.
Radiography personnel shall perform the handling, storage, and shipping cperations.
5.0 INSPECTICriS, TEST AND OPERATING STATUS Inspections, test and operating status of packages for certain special form radioactive material will be indicated and controlled by written procedures. Status will be indicated by tag, label, marking or log entry.
Status of nonconforming parts or packages will be positively maintained by written procedures.
Radiography personnel shall perfom the regulatory required inspections and tests in accordance with written procedures. The Radiation Safety Officer shall ensure that these functions are perfonned.
6.0 CUALITY ASSURANCE RECORDS Records of package approvals (including references and drawings), inspec-tions, tests, operating logs, audit results, personnel training and qualifkations and records of shipments will be maintained. Descriptions of equipment and written procedures will also be maintained.
These records will be maintained in accordance with written procedures.
The records will be identifiable and retrievable. A list of these records, with their storage locations, will be maintained by the Radiation Safety Officer.
7.0 AUDITS Audits for vertfication mf concliance with the Quality Assurance Program will be conducted as described below:
a.
Each cogleted " Radioactive Material Transfer Report" fom (see Radia-.
tion Safety Program) will be reviewed by the Radiation Safety Officer, or his designee, when it is received.. This review will check for proper cogletion of all appropriate portions of the form.
b.
At least once each year, each shipping container will be checked for damage, proper labeling, and identification.
Management shall conduct periodic audits (not to exceed yearly) on the c.
. Radiation Safety Officer for compliance with the program's procedures.
Audit will be conducted using the Quality Assurance Program's Management Audit Form (attached).
'Qh3ROGRAM FOR USE, MAINTENANCE NiD REPAIR OF 2 of 4 SHIPPING CONTAINERS FOR RADI0 ACTIVE,FATERIAL A
{
A Results of audits will be =aintair.ed and reported to =anageant. Audit reports will be evaluated and deficient areas corrected. Audit reports will ce maintained as :: art of tne Quality Assurance records. Personnel perfor=ing audits sr.all have no direct respcnsibility in tne activity being audited.
- ~
,e
~
P i
C-
' UM P E V.
PAGE QA PRCGPAM FOR 'JSE, MAINTENANCE AND REPAIR OF 3 of 4 SHIPPING CCNTAINERS FOR RADICACTI'iE. TERIAL A
V
h
~ sesayw PRESIDEtC VICE PRESIDENT QUALITY CONTROL RADIATION SAFETY FIELD MANAGER MANAGER OFFICER AREA MANAGER PROJECT MANAGER I
\\
I e
N O.
- TITLE
. R E v.
PAGE QA PROGRAM FOR USE, MAINTENANCE AND REPAIR OF
- 4 ne a SHIPPING CONTAINERS FOR RADI0 ACTIVE MATERIAL A
QUALITY ASSURANCE PROGF.AM FOR
[.
9 SHIPPING CO?RAINER INSPECTION (YEA?J.Y)
Assignee Date Due Shipping Container Model No.
S/N Locatien 5pecial Instructions Accept Reoaired Replaced 1.
Condition of Container
~~
~
- 2. ' Danger Peligro cargo Aircraf: Labeling 3.
Attached Package Certificatien (IAEA) 4.
Radicactive Material Special Fom N.O.S.
Labeling
. 5.
Type B Labeling 6.
Package Certificate Labeling (same as Model or Identification No.)
7.
Inside Themal Barrier i
8.
Inside Polyurethane Filler
~
9.
Attach Ring Seal l
l 10.
Container Locking Device (bolt or clip) t I
l Remarks l
Designated Representative Date All shipping centainers shall confom to the requirements of DOT and 10 CFR Part 71.
i l
s
(.
QUALITY ASSURANCE PROGPR4 Peabcdy. estra
.....................r.
PRIAGEMENT AUDIT Radiation Safety Officer Date 1.
Copy of the Quality Assurance Program on file 2.
The Quality Assurance Program is adequately established and implemented
~
3.
Records of inspection (yearly) for shipping containers being raintained 4.
Records of " Radioactive Material Transfer Reports" (figure 3) maintained 5.
Is adequate control of shipping containers being maintained
~~
- 6.. Are audit results being reported to management
~
~.
....=-
- 7. - Management's inspection of at least one (1) shipping container'for~c5dhliance with program requirements.
(If additional containers are inspected use reverse side)
.-.r.
~ ~ " '
Shipping Container Model No.
S/N
- = _. _. ~
Location
~ ~ ~ ~ ~
~ Accept Poor '~ Defective
- a. Condition of container
- b. Danger Peligro Cargo Aircraft Labeling
- c. Package Certification (IAEA) attached
- d. Padioactive Material Special Form N.0.5. Label
- e. Type B Labeling
- f. Package Certificate Labeling (same as model or Identification No.)
- g. Inside Thermal Barrier
- h. Inside Polyurethan Filler
- i. Attach Ring Seal
.j. Container Locking Device (bolt or clip)
J.. *-
Remarks No items of non-compliance found 1
] Areas of non-compliance fourd I
Audit Performed By Title RSO Letter of corrective action for areas of noncompliance issued on (Date)
Shipping Container Model No.
S/N Location Accept Poor Defective
- a. Conditian of container
- b. Danger Peligro Cargo Aircraft Labeling
- c. Package Certification (IAEA) attached
- d. Padioactive Material Special Form H.O.S. Label
- e. Type B Labeling
- f. Package Certificate Labeling (same as model or Identification No.)
- g. Inside Thermal Barrier
- h. Inside Polyurethan Filler
- 1. Attach Ring Seal J. Container Locking Device (bolt or clip)
L Remarks Shipping Container Model No.
S/N Location Accept Poor Defective
- a. Condition of container
- b. Danger Peligro Cargo Aircraft Labeling
- c. Package Certification (IAEA) attached
- d. Padioactive Material Special Form N.0.S. Label
- e. Type B Labeling
- f. Package Certificate Labeling (same as model or Identification No.)
- g. Inside Thermal Barrier
- h. Inside Polyurethan Filler
- i. Attach Ring Seal
- j. Container Locking Device (bolt or clip)
Remarks l
l
{
e l
I
-..,.. ~..
_ _, _ _ _, - _ ~ _. _ _, -. _ _ _ _ _. -. _
FIGGI 3
~
~
1 Peated/....ec....9..
PADICACITVE 2dE?lAI. W2ctrr. se e t-
. CESh :.
IXII ISvMr.
CA? SCI.E S/G CGIES E G O!TCPI T /I G
. VEE S/N r
M ic::..r. ) TXV.
ID
~
FF.ASCtl KR.IR,th:.:u.
^
N 5J SC G G sr.yt.c a.u R SCGG REILTCU l l
MAIECSCIICRCU CR IW94ED I i
UST ANY PEGANICAL Lt.:wn CR MAIJUmts
~
SF'IF. tit ?FIFAr.w 3Y AL h 3Y SFIFFIM; CIlhN I
C=n n#-e shall be a P pe 3 desigr.ed to ::ieet with the reqd. raw s cf D0r.
f 1.
. W ing Cer =#- e S/N 6.
T' b W v'th " Radio
~
2.
Cerd***em of Shipping Container ef~a15pecia1 F
3.
Danger Pal #gm Cargo Aircraf:
7-y,gy yg g.7
- 3, IP Cnly Iabel A##4yad g 4,4 Iabel A#8' M 4.
Package. Certification or 8.
r-+
A:;=:.al Affixed 9.
Fad *-active Yellow 5.
Labeled with Package Certificate Tm M h A43%mA
- ' ~
(Podel or Identification No.)
Type of Iahel:- Yelles.r H l l
Yellow III l l
SLTIEY & LNAL PRICR 'ID SHIIM:T SCEFAG T EXiuuu:. IEVIG PR/HR E 35" is/ER SCEFACE CE CIITIADEIt
}S/ER AT 36"
}S/EK l
.=....n.,,.,nn.,...,,,.,nn.,....,..,
)
au a
=,n:. u = =.- :. = :,:.:.:.:. u u ;. =, =,n=,n : u u : a =...=, =n..
=,nn:.
ann: :n u u =, ;, :, u
,.,,n.,n-.,n.,,..
,.,.,---..n.,n.
.,...,n..
~. - - - - ~.
., ~. ~. ~.
~.. - -., - - - - - ~. ~. - - ~. ~, ~, ~.
~.,. - ~. ~, ~. ~.
~..
SLET? T )kERIAI. AS RE.uu.vr.u i
SGFACE T COC.AISEIt MP/ER AT 36" IS/ER s.r.:AG T ECPCSLE IEVIG PE/ER AT 35"
)S/ER DAII h ws is:aAD BY l
(Shirper cccplete top half of reper: ar.d ship with expost:re devi.ce. Iniivital re-ceivi..g :sterial ecx:plete bot:acz (s=vey of enterial as received) and re =n by = mil to crigira:cr (jebsite) with a copy to the RSO.
..- -.-.- __ _,_ ~. _ _ _ _
(
0, UNITED STATES NUCLEAR REGULATORY COMMISSION
{ yy,
,, g E
W ASHINGTON,0. C. 20555 g g,g" /.::
%,..... f E-~ r 7 1STs FCTC:Ff.0 71-C064 Peabody Testing /X-Ray Engineering Co.
ATTN: Mr. Tom W. Cuthbertson 1118 Chess Drive i_
Foster City, CA 94404 Gentlemen:
Enclosed is Quality Assurance Program Approval for Radioactive Material Packages No. 0064, Revision No. O.
Please note the conditions included in the approval.
In particular, the attachment identified on page i of the application is not included as part of your QA program.
Sincerely,
&b Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety, NMSS
Enclosure:
As stated Ng q
" s-
- g 4
g.
- h hb 2
i g$
b NN36f ai etv
hr.C /ORM 311 U.S.NUCt. EAR REGULATORY COMMISSIEN
- 1. APPEGVAL NUM3En 0064 QUA1.lTY ASSURANCE PROGRAM APPROVAL M:-"'
nEvisioN NuMeEn FOR RADIOACTIVE MATERIAL PACKAGES 0
Pursuant to the Atomic Energy Act of 1054, as amended,the Energy Renrganization Act of 1974, as amended,and Tit?e 10, Code of Federal Regulations, Chapter 1, Part 71, and in reliance on statements and representations heretofore made in item 5, by the per*on named in item 2,the Quality Assurance Program identified in item 5 is hereby approved. This approval is issued to satisfy the requirements of Section 71.51 of to CFR Part 71. This nproval is subject to all applicable rules, regulations, and orders of the Nuclear Regulatory Commission now or hereafter in effect and to any conditions specified below.
- 2. N AM E
- 3. EXP? R ATION D ATE Peabody Testinc/X Rav Encineerino comcinv
~~"P sTmEET AconEss
~
~
~
November 30, 1984 1118 Chess Orive
- 4. oOCKET NUMeEM CITY ST AT E ZIP CQ Das Fnstar city CA 94404 71-0064 S. QUALITY ASSUR ANCE PMQGR AM APPLICATION DATEts)
August 24, 1979 S. CONQ4TIOpus -
A.
Activities conducted under applicable criteria of Appenidx E of 10 CFR Part 71 to be executed with regard to transportation packages by November 1,1979.
B.
The shipping activities authorized by this approval are procurement, mainten-ance, repair, and use. All other shipping activities (f.e., design, fabrication, assembly, testing, and modification) shall be satisfied by obtaining certifi-cations from package suppliers that these activities were conducted in accordance with an NRC-approved QA program.
It shall remain the responsibility of the licensee-user that all transportation activities meet the requirements of 10 CFR 571.51.
C.
The attachment identified on page i of the application is not included as part of your QA program.
s pj p V MR TdE tdS.NUCtMRAECULATORY COMMISSION gr M Jfg M g sicNATumE oATE Charles E. MacDonald, Chier, Transporation Certification Branch, SE? 0 71979 Division of Fuel Cycle and Material Safety. NMSS 1
Model No. 6717-B Packaaing USA /6717/B Addressees: w/ encl Ltr dtd:
Argonne National Laboratory Lawrence Livermore Laboratory ATTN:
Mr. Elbert M. Kwirant ATTN: Mr. Stephen Chin 9700 South Cass Avenue P.O. Box 808 Argonne, IL 60439~
University of California Livermore, CA 94550 Argonne National Laboratory ATTN:
Mr. R. U. Curl Metals Testing Company, Inc.
P.O. Box 2528 ATTN: Mr. John H. Leins, Sr.
~ ~ ~
Idaho Falls, ID 83401 P.O. Box 213 Daniel International Corporation ATTN: Mr. Ronald N. Prewitt Midstate Testing Laboratory Daniel Building ATTN: Mr. Thomas J. Keilman Greenville, SC 29602 7943 New Jersey Avenue Hammond, IN 46323 GEO CONSTRUCT 10NTESTIMg Department of the Navy ATTN:
Mr. R. L. Seacat Peab y s i11 M 1118 CHESS DRIVE Norfolk Naval Shipyard Enginaciq C;.;gany FOSTER CITY, CA. 94404 Portsmouth, VA 23709 ATTN: Mr. Tom W. Cuthbertson 1118 Chess Drive Gamma Industries Foster City, CA 94404 ATTN: Mr. Harry D. Richardson P.O. Box 2543 Source Prod. & Equip. Co., Inc.
Baton Rouge, LA 70821 ATTN:
Mr. R. F. Dicharry 625 0xley Street General Dynami s Kenner, LA 70062 ATTN:
Mr. R. H. Surprenant Eastern Point Road Space Science Services, Inc.
Groton, CT 06340 ATTN:
Mr. Donald A. G '1er
~
P.O. Box 20126 Gulf Nuclear, Inc.
Orlando, FL 32814 ATTN:
Mr. Walter P. Peeples, Jr.
P.O. Box 58865 Twin City Testing & Engr. Lab.
Houston, TX 77058 ATTN: Mr. Howard T. Schulze 662 Cromwell Avenue St. Paul, MN 55114 4
1SSS8
._- - -.