Metropolitan Edison Company e

i Post Office Box 480 Middletown, Pennsylvania 17057 Writer's Direct Dial Nurnber April 22,1981 s

L1L 122 N

m fl ~ h Office of Inspection and Enforcement d

Attn:

B. H. Grier, Director S

q[,

[

Region I 2

U 4

U. S. Nuclear Regulatory Commission 1

'*I'O 2 7 Jggy,

~

U v s %,

631 Park Avenue

%'8sD%

King of Prussia, PA 19406

/g.,

(3

Dear Sir:

Three Mile Island Nuclear Station, Unit 1 (TMI-1)

Operating License No. DPR-50 Docket No. 50-289 Radioactive Effluent Release Report Correction Enclosed please find two revised copies of Table 4 of the Radioactive Effluent Release Report for the period of June 1, 1980 through December 31, 1980 sub-mitted February 28, 1981 (L1L 053). This table has been modified to correct a typographical error as noted by the margin bar.

Sincerely, Signed ll.D. liukill H. D. Hukill Director, TMI-l HDH:DGM:1ma Enclosure cc: ' Director, Office of Inspection and Enforcement (6 copies)

U. S. Nuclear Regulatory Commission Washington, D.C.

20555 Director, Office of Management Information & Program Control U. S. Nuclear Regulatory Commission Washington, D.C.

20555 8104280 MP Metropohtan Ed: son Com;:any is a Member of the General Pubhc Utiht:es System

IAELE 4 s

N PICAL GASEOUS EFFLUENT LLD (Lower Limit of Detection) VALUES ASSLMPTIONS :

Sample Volume (Marinelli) 1640 cc, Sample Volume (Particulate and Charcoal Filters) 5.7E8 pc Sampling Rate 2 cfm or 5.66E4 cc/ min Sampling Time I week or

.IE4 min Sample Volume (Tritium bubbled thru water) 7.56E5 cc Sampling Rate 75 cc/ min

'~

Sampling Time

_ IE4 min Sample Counting Time: a & 'H = 20 min; 8 = 10 min; y = 1000 sec l

Sample Counters: y emitters

. 25% Ge(Li) a or B Proportional C.unter sH.

Liquid Scinti11ation Counter ISOTOPE UCi/cc LLD TYPE SAMPLE 4

Gross Alpha a

IE-15 Particulate Filter Paper Gross Bet.a 8

1E-14 3

Tritium H

IE-6 Air bubbled thru water by a fritted disc or Fisher Pdlligan Eas washer es Krypton-85 Kr 2E-5 Marinelli esm Krypton-85m Kr 4E-8 87 Krypton-87 Kr 4E-8 Krypton-88

    • Kr 2E-7 Xenon-133 iss,

ig_7 n

y Xenon-133m 183*Xe 6E-8 Xenon-135 lasXe 3E-8 Xenon-135m 185"Xe 4E-7

- Xenon-138 18'Xe 4E-7 l'1 Iodine-131 1

3E-8 Iodine-133 13'I 3E-8 Iodine-135 1ssI 2E-7 131 Iodine-131 I

2E-14 Charcoal Filter 188 l

Iodine-133 I

1E-13 183 1E-12 Iodine-135 I_. _

L Manganese-54 s*Mn 2E-14 Particulate Filter Paper Iron-59 5'Fe 2E-14 ss Cobalt-58 Co 2E-14

+

Cobalt-60

Co 2E-14 55 Zinc-65 2n SE-14 Strontium-89

Sr 2E-14 Strontium-90

Sr 2E-14 Molybdenum-99 "Mo 7E-15 l

l'3 Ruthenium-103 Ru IE-13 Silver-110m 12omAg IE-13 Cesium-134 18"Cs 2E-14 187 Cesium-137 Cs-2E-14 1"1 Cerium-141 Ce IE-14 Cerium-144 1**Ce 6E-14 l

i se t