r 4~
N Commonwealth Edison
[O
) One First National Pina. Chicigo, Illinois
(
')
Aridr:ss R ply to: Post Office Box 767 N
/ Chicago, filinois 60690
~
April 10, 1981 N
h8 lt gpg 2 2198W Mr. Steven A. Varga, Chief 3
Operating Reactor Branch #1 5
,us w o* );
Division of Licensing
,,,#55*
Office of Nuclear Reactor Regulation g'
[9 A
U.
Nuclear Regulatory Commission p
Wc ington, D.C. 20555 m
Subject:
Zion Station Units 1 and 2 Interim Supplemental Analysis to Account for Cladding Swelling and Rupture Models for Zion Units 1 and 2 LOCA Analysis NRC Docket Nos_._50-295 ana 50-304
References:
(a)' October 22, 1979 letter from D. L. Peoples to H. R. Denton (b) January 21, 1981 letter from S. A.
Varga to J. S. Abel (c) January 8, 1980 letter from D. L. Peoples to D. G. Eisenhut
Dear Mr. Varga:
In Reference (a) Commonwealth Edison Company submitted an application for license amendment to increase the total nuclear peaking factor, Fg to 2.20.
Per Reference (b) the NRC Staff indicated that their review of that application was nearly complete.
However, the NRC Staff indicated that adaitional information was necessary to complete their review.
Specifically, the NRC Staff requested Commonwealth Ecison to provide an interim supplemental analysis assessing the impact of:
1)
A Westinghouse calculational error involving temperature - ramp rates used in cladding burst tests; and 2)
NUREG-0630 models involving cladding swelling and rupture.
The supplemental analysis was to be similar to that provided by Commonwealth Edison in Reference (c); however, updated to include the appropriate parameters from the LOCA analysis submitted in Reference (a).
810.4230 Y f
. Attachment 1 to this letter contains the-requested interim supplemental analysis.
In. summary, this analysis indicates'that the-Fg peaking factor limit of 2.20 identified in the LOCA analysis of Reference-(a) must be reduced by 0.03 to offset penalties.resulting
.from application of the NRC fuel rod models.
Thus, the resultant Fg peaking ~ limit for Zion Units.1 and 2 becomes 2.17. contains the appropriate changes'to the proposed technical specifications of. Reference (a) necessitated by the interim supplemental analysis of Attachment 1.
The interim analysis (Attachment 1) and. revised technical specifications (Attachment 2) have been reviewed and approved by Commonwealth Edison On-Site and Off-Site Review with the conclusion that the plant can be operated safely in accordance with the proposed changes.
Please aadress any questions that you might have'concerning this matter to this office.
One (1) signed original and thirty-nine (39)-copies of this letter are provided for your use.
Very truly yours,-
-r,re. %
T. R. Tramm Nuclear Licensing Administrator Pressurized Water Reactors cc:
Resident Office - Zion 12778 M
ATTACHMENT 1 Zion Station Units 1 and 2 NRC Docket Nos. 50-295 and 50-304 Interim Supplemental Analysis i
I f
g A.
' Evaluation of the potential impact of using fuel' rod models presented in draft NUREG-0630 on the Loss of Coolant Accident (LOCA) analysis for Zion thits 1 and 2 This evaluation is based on the limiting break LOCA analysis identified as follows:
BREAK TYPE - DOUBLE ENDED COLD LEG GUILLOTIE
~
BREAK DISCHARGE COEFFICIENT 0.6-WESTINGHOUSE ECCS EVALUATION MODEL VERSION February 1978 w/LHI CORE PEAKING FACTOR 2.20 HOT ROD MAXIMUM TEW ERATURE CALCULATED FOR THE BURST REGION OF THE CLAD -
1827.3 0F = PCTB ELEVATION 6.25 Feet.
HOT R0D MAXIMUM TEWERATURE CALCULATED FOR A NON-RLPTURED REGION OF THE 0F = PCTN
___ 2048.3 CLAD ELEVATION -
7.5 Feet.
CLAD STRAIN DURING BLOWDOWN AT THIS ELEVATION 4.24 Percent MAXIMUM CLAD STRAIN AT THIS ELEVATION -
10.
Percent Maximum temperature for this non-burst node occurs when the core reflood rate is greater than 1.0 inch per second and reflood heat transfer is based on the FLECHT calculation.
AVERAGE HOT ASSEIOLY ROD BURST ELEVATION -
N/A Feet HOT ASSEMBLY BLOCKAGE CALCULATED -
0 Percent 1.
BURST NODE The maximum potential impact on the ruptured clad node is expressed in letter NS-TMA-2174 in terms of the~ change in the peaking factor limit (FQ) required to maintain a peak clad temperature (PCT) of 0
2200 F and in terms of a change in PCT at a constant FQ. Since the clad-water reaction rate increases significantly at temperatures above 2200 0F, individual affects (such as dPCT due to changes in several fuel rod models) indicated here may not accurately apply over large ranges, but a simultaneous change in FQ which causes the PCT to remain in the neighborhood of 2200.0F justifies use of this evaluation procedure.
s
. From NS-TMA-2174:
For the Burst Node of the clad:
0.01 A FQ -> + 1500F BURST NODE APCT Use of the NRC burst model and the revised Westinghouse burst model could require an FQ reduction of 0.027 The maximum estimated impact of using the NRC strain model is a required FQ reduction of 0.03 Therefore, the maximum penalty for the Hot Rod burst node is:
d PCT 1 = (0.027 + 0.03) (1500F/0.01) = 855.00F Margin to the 22000F limit is:
APCT2 = 2200.0F - PCTg = 372.7 0F The FQ reduction required to maintain the 22000F clad temperature limit is:
FQB = (J PCT1 -dPCT ) (.01 A FQ) 2 1500F
= (855.0 - 372.7)
(.01) 150 0.03 (but not less than zero).
4
=
2.
NON-BURST NODE The maximum temperature calculated for a non-burst section of clad typically occurs at an elevation above the core mid-plane during the core reflood phase of the LOCA transient.
The potential impact on that maximum clad temperature of using the NRC fuel rod models can be estimated by examining two aspects of the analyses. The first aspect is the change in pellet-clad gap conductance resulting from a difference in clad strain at the non-burst maximum clad temperature node elevation. Note that clad strain all along the fuel rod stops after clad burst occurs and use of a different clad burst model can change the time at which burst is calculated. Three sets of LOCA analysis results were studied to establish an acceptable sensitivity to apply generically in this evaluation.
The possible PCT increase resulting from a change in strain (in the Hot Rod) is +20.0F per percent decrease in strain at the maximum clad temperature locations. Since the clad strain calculated during the reactor coolant system blowdown phase of the accident is not, changed by the use of NRC fuel rod models, the maximum decrease in clad strain that must be considered here is the difference between the " maximum clad strain" and the " clad strain at the end of RCS blowdown" indicated above.
}
-., - ~
e
. Therefore, f 200F j
A PCT 3=(.01 strain / (MAX STRAIN - BLOWDOWN STRAIN) t 20
.01 (0.10 - 0.0424)
=
115.2
=
The second aspect of the analysis that can increase PCT is the flow blockage calculated. Since the greatest value of blockage indicated by the NRC blockage model is 75 percent, the maximum PCT increase can be r timated by assuming that the current level.of blockage in the analysis (indicated above) is raised to 75 percent and then applying an appropriate sensitivity formula shown in NS-TMA-2174.
Therefore, f PCT 4 = 1.250F (50 - PERCENT CURRENT BLOCKAGE)
+ 2.36 F (75-50)
= 1.25 (50 -
) + 2.36 (75-50) oF
=-
d PCT 4=0.
If PCTN occurs when the core reflood rate is greater than 1.0. inch per second, APCT4=0. The total potential PCT increase for the non-burst node is then A PCTS = A PDT3 + dPCT4 = 115.2 Margin to the 22000F limit is dPCT6 = 22000F - PCTN = 151.7 The FQ reduction required to maintain this 22000F clad temperature limit is (from NS-TMA-2174).
5-APCT)(f.01FQ
}
6 100F APCT
/
l FQN = (d PCT FQN =
0 but not less than zero.
The peaking factor reduction required to maintain the 22000F clad temperature limit is therefore the greater ordFQB and AFQ e N
or, 8 FQPENALTY =
0.03 i
8.
The effect on LOCA analysis results of using improved analytical and modeling techniques (which are currently approved for use in the tJpper j
Head Injection plant LOCA analyses) in the reactor coolant system binwdown-calculation (SATAN computer code) has been quantified via an analysis which was submitted to the NRC for review on October 22, 1979 per a
+
. D. L. Peoples to H. R. Denton letter. Assuming the benefits associated with those model improvements are approved,-then the LOCA peaking factor limit, FQ, for Zion Units 1 and 2 is 2.20.
C.
The peaking factor' limit, FQ, identified in Section (B) above adjusted by the JhFQPENALTY calculated in Section-(A) above to offset penalties '
resulting from application of the NRC fuel rod models results in a LOCA peaking factor limit for Zion Units 1 and 2 of:
T FQ = 2.20 - 0.03 = 2.17 ID:1745A I
,