h

\\

Fcrm NRC418 U.S. NUCLEAR REGUt AToRY COMMISSION M 7i CERTIFICATE OF COMPLIANCE jg CFR H For Radioactive Materials Packages 1.(a) Certificate Number 1.(b) Revision No.

1.(c) Package identification No.

1.(d) Pages No. 1.tel Total No. Pages 4011 9

IKA /on11/R / )

1

?

2. PRE AMBLE 2.(a)

This certificate is issued to satisfy Sections 173.393a,173.394.173.395, and 173.396 of the Departrnent of Transportation Hazardous Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.

2.(b)

The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10, Code of Federal Regulations. Part 71, ** Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions.**

2.fcl This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Departrnent of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.

3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.(a)

Prepared by (Name and address):

3.(b)

Title and identification of report or application:

Advanced Medical Systems, Inc.

Pickir Corporation application dated 1020 London Road September 25, 1973.

Cleveland, OH 44110 3.lc)

Docket No.

7]-gg))

4.

CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicable, and the conditions specified in item 5 below.

5. Description of Packaging and Authorized Cantents, Model Number. Fissile Class, Other Conditions, and

References:

(a) Packaging (1) Model No.:

E-MEH-00-00004 (2) Description l

An overpack that provides impact and thermal protection for a teletherapy head assembly.

The cubical overpack consists of laminated 2x4 hardwood maple panels bolted together and covered with 16 gage steel panels.

l l

Reinforcing steel straps and angles are welded together and spaced to limit the openings between them to less than 6 inches.

Skid runners are provided to facilitate fork lift usage.

Dimensions of the overpack are 36"x42"x40.5" with a maximum gross weight of 4000 pounds.

(3) Drawings l

l The packaging is constructed in accordance with the following Picker Corporation Drawing Nos.:

D-MEH-00-00004, Sheets 2 thru 10; with i

j teletherapy head Drawing Nos.; A-40064; A-40066; A-40063; A-40065; A-42209 (A thru 0); A-42208A; A-0067; A-42211; A-T22-86; C-3800-A; A-42208 (A thru D); E-182545A, and E-18972A.

l l

8104 200f3J l

t

Page 2 - Certificate No. 9011 - Revision No. 2 - Docket No. 71-9011 5.

(b) Contents (1) Type and form of material Co-60 sealed sources that meet the requirements of special form as defined in 10 CFR 571.4(o).

The sources are to be packaged in a secondary inner container (teletherapy head) as described in Item 5(a)(3).

(2) Maximum quantity of material per package 13,680 curies, with a radioactive decay heat load not to exceed 200 watts.

6.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 971.12(b).

7.

Expiration date:

March 31, 1986.

REFERENCE Picker Corporation application dated September 25, 1973.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety APR 08;og; Date: