Forwards LER 81-042/01T-0
Date released: 01/17/2020 Download: ML20003E890


LER 81-042/01T-0:on 810327,during Investigation of Ctip Machine Isolation Ball Valve Operability,Power to Retract TIP Probe Was Lost.Caused by Design Deficiency Which Allows Removal of Power to Probe Drive Motor While de-energized
ML20003E895
Person / Time
Site: Brunswick 
Issue date: 04/10/1981
From: Pastva M
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20003E895 (3)
Forwards LER 81-042/01T-0
ML20003E889
Person / Time
Site: Brunswick 
Issue date: 04/10/1981
From: Dietz C
CAROLINA POWER & LIGHT CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20003E889 (1)