ML20003D919

From kanterella
Jump to navigation Jump to search
Annual Environ Operating Rept for 1980
ML20003D919
Person / Time
Site: Crane  
Issue date: 03/31/1981
From:
Metropolitan Edison Co
To:
Shared Package
ML20003D914 List:
References
NUDOCS 8104010404
Download: ML20003D919 (14)


Text

_

/

1

'.)

t METROPOLITAN EDISON COMPANY TIIREE MILE ISLAND NUCLEAR STATION 1980 ANNUAL ENVIRONMENTAL OPERATING REPORT l'UR UNIT 1 AND UNIT 2 Prepared by TML Environmental Controls Metropolitan Edison MARCll 1981 810401Oh%

This document and the referenced reports fulfill the requirements for the " Annual Environmental Operating Report" as described in the Three Mile Island Nuclear Station, Unit I and Unit 2 Environmental Technical Specifi-cations, dated April 19, 1974 and February 8, 1978,respectively.

The following table references sections of the " Annual Environmental Operating Report" to the appropriate sections of these documents.

l I

l i

SECTION REFERENCE Annual Environmental Operating Report

'DfI-1 TMI-2 ETS ETS 1.

Thermal Characteristics of Cooling Water Discharge 2.1 3.1.1.a (1) 2.2.3 3.1.1.a (2) 2.

pH 3.

Suspended and Dissolved Solids 2.2.2 4.

Biocide 3.1.1.a (3) 5.

Water Quality Analysis 4.2.2 3.1.1.a (4) 6.

Chemical Release Inventory 3.1.1.a (5) 7.

Biotic - Aquatic 4.1.1 3.1.2.a 8.

Biotic - Terrestrial 4.1.2 3.1.2.b 9.

Residual Chlorine Study Programs 2.2.1 4.1 10.

Thermal Plume Mapping 4.2 11.

Hydraulic Effects 4.3 12.

Erosion Control Inspection 4.4 4.5 13.

11erbicide Applications 14.

Unusual or Important Environmental Events 4.6.1 15, Exceeding Limits of Other Relevant Permits 4.6.2 16.

Environmental Program Description Document 5.5.1 17.

Changes in Procedures, Station Design, or Operation 5.5.4.c 18.

Changes in Environmental Technical Specifications 5.7.1 19.

Changes in Permits and certifications 5.7.2 11

TABLE OF CONTENTS _

Sectlon_

Unit *

Page, 1.

Thermal Characteristics of Coeling Water Discharge 1, 2 1

2.

pil.

1, 2 2

3.

Suspended and Dinsolved Solids 1

4 4.

Blocide 2

5 5.

Water Quality Analysis 1, 2 6.

Chemical Release Inventory 2

5 7.

Elotic - Aquatic 1, 2 8.

Blot ic - Terrestrial 1, 2 9.

Residual Chlorine Study Program 1, 2 6

10.

Thermal Plume Mapping 2

11.

Ilydraulic Effccts 2

12.

Erosion Cont rol Inspection 2

7 13.

lierbicide Applications 2

7 14.

Unusual or Important Environmental Events 2

7 15.

Exceeding 1.imits of Other Relevant Permits 2

7 16.

Environmental Program Description Document 2

8 17.

Changes in Procedures, Station Design, or Operation 2

8 18.

Changes in Environmental Technical Specifications 2

8 19.

Changes in Permits and Certifications 2

8

  • As required by TF11-1 and TMI-2 Environmental Technical Specifications
    • "An Ecological Study of the Susquehanna River in the Vicinity of the Three Mile Island Nuclear St ation - Annual Report 'or 1980", Ichthyological Associ.ucs, Inc., Flarch 1981.
      • "1980 Monitoring of Cooling Tower Operational Effects on Vegetation in the Vicinity of the Three Mile Island Nucicar Station", NUS Corporation, January 1981.
        • "llydraulic Survey, Three Mile Island Nuclear Station, June 1980", Gilbert Associaten, Inc., June 1980.

111 1.

TilERMAL CHARACTERISTICS OF COOLING WATER DISCHARGE In 1980 the temperature of the ambient intake water, the teraperature of the discharge water at Outfall 001, and the flow rate of the discharge water at TSree Mile Island Nuclear Station (TMINS) were continuously monitored.

The date, time, terperature, and flow rate were recorded at the Station.

The minimum, average, and maximum of the discharge ten.peratures and the changes in temperatures (AT) between the intake and discharge and the flow rates are summarized and reported below:

Temperature ( F) of Discharge Water c

Month Min.

Ave.*

Max Month Min.

Ave

  • Max Jan.

32.5 34.8 38.6 July 76.8 82.6 90.7 Feb.

33.0 34.8 40.9 Aug.

72.1 81.0 87.9 March 32.8 39.5 45.7 Sept.

61.8 73.6 86.4 April 42.8 52.3 62.5 Oct.

46.5 57.9 70.3 May 55.2 66.5 76.7 Nov.

37.1 43.1 51.3 June 65.7 75.7 85.7 Dec.

31.7 35.0 43.7 AT ( F) Eetween Intake and Discharge Water Month Min.

Ave.*

Max.

Mo-th Min.

Ave

  • Max.

Jan.

+1. 0

+1.7

+2.5 July

-0.1

+0.6

-3.3 Feb.

+1.0

+1.7

+3.0 Aug.

-0.1

-0.6

-2.9 Parch

-0.3

+1.8

+4.2 Sept.

0 40.6

+2.1 April

+1.0

+2.0

+2.4 Oct.

0

+0.2

+1.5 May

+1.1

+1.8

+2.4 Nov.

-0.1

-0.1

+1.7 Junc

+0.8

+2.0

+3.2 Dec.

-0.1

-0.3

+1.2

  • Represents average of daily averages for given month

l Flow Pate (Millions of Gallons _Per Day _) of Discharge Rater Month Hin.

Ave.

Max.

11onth Hin.

Ave.

Max.

~

Jan.

60.3 67.3 72.9 July 39.8 42.3 46.8 Feb.

52.6 60.2 69.5 Aug.

25.4 41.3 53.4

!brch 54.5 59.8 68.9 Sept.

36.4 40.2 43.1 April 51.1 59.2 71.3 Oct.

35.3 41.4 45.5 May 51.6 61.1 75.7 Nov.

20.8 37.1 44.7 June 38.9 48.0 63.0 Dec.

27.7 40.0 53.5 During 1980, no flow or temperature limitations were exceeded.

Thermal limitations require the temperature of the discharge not to exceed 87 F or i

ambient river temperature with AT values of <5 F per liour, <70F from May through October, and <12 F from November through April.

2. pil During 1980, pil was determined prior to each discharge from the TMINS Unit 1 Neutralizer Tank. The analysis was performed according to an accepted method as described in Standard Methods ~or the Examination of Water and Wastewater (American Public Health Association 1976)*.

The date, time, and pil of all sampics were recorded on Waste Neutralizing Tank Release Permits.

The minimum, average, and maximum pH values, as well as the number od discharges per month (frequency) are presented below:

Unit 1 Neutralizer Tank Month Min.

Ave.

Max. Freq.

Month Min._

Ave.

Max.

Freq.,.

Jan.

6.55 7.10-7.68 8

July 6.7 6.99 7.35 4

Feb.

6.7 7.46 8.8 5

Aug.

6.77 7.05 7.53 5

- Ibrch 7.14 7.35 7.55 2

Sept.

7.18 7.50 7.8 3

April 6.82 7.32 8.32 7

Oct.

6.83 7.36 7.75 3

May 6.92 7.33 7.69 6

Nov.

6.69 7.08 7.37 7

June 6.85 7.16 7.6 9

Dec.

6.72 7.06 7.6 2

  • American Public Health Association, 1976.

Standard Methods for the Examination of Water and Masteuater, Fourteenth Edition. Prepared and published jointly by the American Public 11ealth Association, American Unter Works Association, and Water Pollution Control Federation, Washington, D.C., 1193 p.

I I

Iv us r within the specification

. nge f 0

1 Unii 2 Neutralizer Tank

{

There were no releases throughout 1980 for TMI 2 Neutralizer Tank 4

i During 1980, the monthly minimum, average, and maximum pil in intake (I) water from the Susquehanna River and discharge (D) water from TMINS Discharge 001 (main discharge) are presented below:

pil of Intake and Diccharge Water l

Minimum Average

!!aximum j

Month I

D I

D I

D Jan.

7.15 6.69 7.37 7.52 7.76 7.89 Feb.

7.37 7.58 7.69 7.77 7.93 8.11 March 7.42 7.87 7.79 8.14 8.15 8.41 April 6.93 6.95 7.09 7.27 7.31 7.48 1

May 7.42 7.96 7.96 8.23 8.34 8.45 June 7.39 7.45 8.02 8.02 8.35 8.34 July 7.54 8.13 8.03 8.51 9.75 8.75 Aug.

7.90 7.95 8.29 8.41 8.59 8.67 Sept.

7.89 7.87 8.20 8.18 8.59 8.56 i

Oct.

7.77 7.82 8.03 8.06 8.30 8.39 Nov.

7.01 7.55 7.44 7.97 7.97 8.28 4

Dec.

7.08 7.60 7.35 7.69 7.73 7.78 An analysis of the data indicate that all pli values were within the specification range of 6.0-9.0 for discharges.

,y-m,

---,-_,.y-__--,-----_w.--iry#r-

.w

+ -, + -

- -+--

3.

SUSPEN,DED Af;D DI SSO1NED 5011DS' During 1980, the monthly minf rnum, average, and maximum concentrations of total r,ur. pended solids and total dissolved solids measured fro's intake (I) water from the Susquehann.i River and discharge (D) water from *1 MINS Discharge 001

~

-(main discharge) are presented below:

Total Suspended Solids (PPM)_

Total Dissolved Solids (PPM)_

!!!nimum Average Maximum Minimum Average Maximum Month I

D I

D I

D I

D I

D I

D Jan.

1 4

4.5 10 11 20 121 143 188 163 338 194 Feb.

I 1

7 4

12 7

162 202 215 260 253 359 March 1

4 1

34 1

64 183 236 198 256 213 276 April 3

21 16 72 26 218 83 103 101 115 121 131 May 4

16 18 22 23 27 109 155 162 209 210 319 June 12 18 24 29 37 50 153 124 185 192 218 239 July 1

20 11 29 19 39 205 256 243 277 270 296 Aug.

'4 21 55 81 220 222 240 268 315 337 510 555 4

Sept.

16 16 18 21 19 27 275 315 377 331 519 340 Oct.

I 1

8 12 14 24 291 302 355 339 453 373 f

1 ov.

<1

<1 4

6 12 14 199 235 261 281 331 317 Dec.

I 1

2 4

5 11 183 192 234 241 340 303 All values presented are below the concentrations specified for suspended &,Jids and dissolved solids in the discharge water from TMINS.

These specifications limit the concentration of dissolved solids to less than 500 ppm as a monthly average and 700 ppm at any time.

Suspended solids may not exceed 560 ppm at any time.

I

-4.

BIOCI D_E i

During 1980, chlorination was conducted only _ once (March 26) at Three Mile Island Nucicar Station.

A grab r: ample from Outfall 001 (main discharge) was taken when the maximum residual chlorine concentration was expected. The sample was taken to the chemistry laboratory and analyzed for total residual chlorine by amperometric titration technique as described in Standard Methods for the Examination of Water and Wastewa'ter (American Public 11ealth EsbEllitEnT 1976).

No residual chlorine was detected in this sample.

5.

WATER QUALITY ANALYSIS

~

Refer to:

"An Ecological Study of the Susquehanna River in the Vicinity of the Three Mile Island Nuclear Station - Annual Report for 1980".

Ichthyological Associa t es, Inc., March 1981.

6.

CllD11 CAL RELEASE INVENTORY During 1980, the chemicals used at Three Mile Island Nuclear Station and' discharged to the Susquehanna River aquatic environment, excluding chemicals used in laboratories, were tabulated f rom station inventory and operating records. The chemical nane, the system and unit from which the chemical was released, and the amount of chemical inventoried during the year are summarized and reported below:

Amount Used Chemical Name Source of Release (Callons)

Sulfur;: Acid HT-T-6, Ivr Storage Tank 14,044 (95% by Weight)

Unit 1 Sulfuric Acid Industrial Waste Treatment 225 (95% by Weight)

(Carboys X 15) Unit 1 Sulfuric Acid WT-T-6, LAWT Storage Tank, 2,905 (95% by Weight)

Unit 2 Sodium Hydroxide WT-T-7, IWT Caustic Tank,

15,000 (50% by Weight)

Unit 1 Sodi am Hydroxide WT-T-7, LAWT Caustic Tank, 2,500 (50% by Weight)

Unit 2 Sodium llypochlorite Pretreatnent Bldg.

900 (10-15% hy Weight)

Unit 1 The amounts of the chemicals used and discharged were less than those addressed in the Final Supplement to the Final Environmental St atement related to operation of the Three Mile Island Nuclear Station, Unit 2, dated December 1976, Docket No. 50-320, U. S. Nuclear Regulatory Commission.

7.

BIOTIC - AQUATIC Refer to:

"An Ecological Study of the Susquehanna River in the Vicinity of the Three Mile Island Nuclear Station - Annual Report for 1980", !chthyological Associates, Inc., March 1981. (Attached) 8.

BIOTIC - TERRESTRIAL Refer to:

"1980 Monitoring of Cooling Tower Operational Ef fects on Vegetation in the Vicinity of the Three Mile Island Nuclear Station", NUS Corporation, Jan.oary 1981. (Attached) 9.

RESIDUAL CHLORINE STUDY PROGRAM During 1980, the Three Mile Island Nuclear Station chlorinated for one day only (March 26).

No residual chlorine was detected.

A residual chlorine study program was not required or performed.

10.

THERMAL PLUME MAPPING Refer to:

"An Ecological Study of the Susquehanna River in the Vicinity of the Three Mile Island Nuclear Station - Annual Report for 1980", Ichthyological Associates, Inc., April 1981. (Attached)

i

).

11.

IlYDRAULIC EFFECTS Refer to:

"Ilydraulic Survey, Three Mile Island Nuclear Station, June 1980",

Gilbert Associates, Inc., ~ June 1980. (Attached) 12.

EROSION CONTROL INSPECTION On April 18 and 21, 1980, foot patrol inspections were performed on the transmission line corridors associated with the Three Mile Island Nuclear Station (TMINS).

These corridors run from TMINS to the Middletown and llosensack Substations.

No evidence of erosion, as may be associated with transmission line maintenance, was found.

13.

IlERBICIDE APPLICATIONS, During 1980, herbicides were not used in the transmission line corridors associated with the Three Mile Island Nuclear Station.

14.

UNUSUAL OR IMPORTANT ENVIRONMENTAL EVENT During 1980, there were no unusual or important, nonradiological events reculting from the operation of the Three Mile Island Nuclear Station.

15.

EXCEEDING LIMITS OF OTHER RELEVENT PERMITS _

~

During 1980, four noncompliance reports were submitted as required by the Three Mile Island National Pollutant Discharge Elimination System (NPDES)

Permit No. 0009920.

In order to comply with the requirements of Section 4.6.2 of the TMI-2 Environmental Technical Specifications, copies of the noncompliance reports, numbered 80-01 through 80-04, were sent to the NRC.

Noncompliances 80-01 and 80-02 occurred at the Industrial Waste Treatment System (IWTS) which is designated as NPDES-discharge number 107.

These noncompliances were caused by excess loading of the IWTS.

Corrective measures such as recycling of flows have been inplenented when excess load conditions exist.

1 l

I i

_ o 1:oncompliances 80-03 and 80-04 also occurred at the IWTS, discharge number'107.

2 These noncompliances were a result of operator error.

The necessary supervisory ~ steps were taken to preclude future occurrences.

i 16.

ENVIRONMENTAL PROGRAM DISCRIPTION DOCUMENT The Environmental Program Description Document (EPDD) consists of portions of a. series of procedures covering the programs requfi.J by Sections 3.1 and 4 of the Three Mile Island Station Unit 2 Environmental Technical Specifi-cations.

The table on the following page lists these procedures.

During 1980, all procedures contained in the EPDD were revised to reflect administrative changes at THINS.

These changes did not impair the ability of the procedures to satisfy the technical requirements of the ETS.

I 17.

CilANGES IN PROCEDURES, STATION DESIGN, OR OPERATION During 1980, all proposed changes in procedures, station design, or operation were reviewed for potential environment'al impact in accordancr with Environmental Technical Specifications and administrative quality assurance procedures.

The reviews insured that no changes were performed which could cause an adverse environmental impact, or which could change the findings of the Final Supplement to the Final Environmental Statement.

18.

CilANGES MADE TO ENVIRONMENTAL TECllNICAL SPECIFICATIONS 1

The following are changes to the TMI-I or TMI-2 Environmental Technical Specifications for 1980:

TNI-1 ETS Amendment 51 dated 1/28/80 deleted Section 4.0 on Environmental Surveillance and Special Studies.

Amendment 58 dated 9/15/80 moved the organization chart of Section 5 to Figure 6-1 of Appendix A.

TMI-2 ETS Amendment 10 dated 2/11/80 added EPICOR II ventilation system and deleted Section 5.1, 5.2, and 5.3 on preaccident management organization.

= -

. 19.

CilANCES IN PERMITS AND CERTIFICATIONS During 1980, a withdrawal of a nending request for an adjudicatory hearing regarding NPDES Permit No. 0009920 was submitted to the EPA.

The EPA also issued approval to perform Fire Brigade Training with open burning.

A request to leak test two 500,000 ga] Ion storage tanks in Unit 2 whs cubmitted to PaDER.

Copics of the above referenced documents were sent to the NRC.

ENVIRONMENTAL PROGRAM DESCRIPTION DOCUMENT t

Environmental Technical Procedure Procedure Current Revision Specification Section Title Number Number 3.1.1.a (1-3) 4 (5)

Temperature, pu, Biocide, and ECP 1448 1

Chemical Release Inventory 3.1.1.a (4)

Water Quality Analysis ECP 1449 2

3.1.2.a (1) (a)

Benthic bberoinvertebrates ECP 1 50 2

3.1.2.a (1) (b)

Ichthyoplankton ECP 1451 2

3.1.2.a (1) (c)

-Fish ECP 1452 2

3.1.2.a (1) (c)

Population Estimates of Fishes ECP 1475 2

3.1.2.a (1) (c)

Creel Survey ECP 1476 3

3.1.2.a (1) (c)

Movements of Fishes ECP 1478 1

3.1.2.a (2)

Impingement of Organisms ECP 1453 2

3.1.2.a (3)

Entrainment of Ichthyoplankton ECP 1454 2

3.1. 2.b (1)

Aerial Remote Sensing ECP 1456 2

5.1 Residual Chlorine Study Program ECP 1448 (page 6) 1 4.2 Thermal Plume Mapping ECP 1458 2

4.3 Hydraulic Effects ECP 1459 3

4.4 Erosion Control Inspection ECP 1460 1

4.5 Herbicide Applications ECP 1461 1

4.6.1 Unusual or Important Events ECP 0005 (Formerly GP 1473) 1 4.6.2 NRS Nonroutine Reports ECP 0004 1

Special Condition Comparison of Ichthyoplankton Completed Sampling Gear

._