._._

~

l-.,,.....,

. i,t._,

(..

.. ),

- f f

t. l... L 17 NUCLEAR SYSTEMS SAFETY PROGRAM L- (

i EG-81-14 March 26, 1981 i

Dr. Robert E. Jackson,ochief Geosciences Branch 4

Division of Engineering U. S. Nuclear. Regulatory Commission Washington, D.

C.

20555

Dear Dr. Jackson:

i The. purpose of this letter is to provide you with results of our limited analysis for the Seabrook site that you requested some time ago.

We developed the enclosed estimate of the seismic hazard for the'Scabrook site in the same manner that we developed the seismic hazard for the sites involved in the Systematic

{

Evaluation Program (SEP).

We have used the model recommen,ded by NRC and described in Jackson (1980) to specify the hazard for the sites-located in New England, t

Figure 1 shows the results (synthesis) compared to R.G.

1.60

}

scaled to 0.25g (245.4cm/S2) for 5% damping.

The data used to construct this figure are given in Table 1.

3 4

I hope that this is sufficient information however, if not, feel free.to call me and I will be happy to supply you with any additional information you might need.

Sincerely,

'7n

[l W

./

Don L.

Bernreuter, Leader i

l Engi neering Geosciences Group I'

DLB/sa Reference

JACKSON, R.

E. (1980), " Initial Review and Recommendations for Site Specific Spectra at SEP Sites," M2morandum to D.

Crutchfield, July 23, 1980, U.S. NRC.

~

b m -

Table 1 SY!JTilESIS LOADI!1G VAI,UES AT TIIE SEABROOK SITE FOR 5% DAMPED PSEUDO RELATIVE VELOCITY SPECTRUM PERIOD Sy SEC cm/s

.04 1.82

.05 2.44

.08 4.71

.1 6.68

.2 19.79

.3 29.01

.4 33.24 1.0 38.78 2.0 30.89 l

~

riouie 1 SFABR001; REG. GU]DE 1.00 VLfi:.Ub SYNTHESIS 3

10 a

/

w x

N

\\

O

\\

Nj N/

Ns/

Nf E

Ni

/\\

\\

3 ee. cr' -

c

\\

R.G 1.

]

,/

a

/- -

m

/ //

S.D i

. N H

!! '[ syrdarsis 15

/

l, N

,ciggg

[

f,,

$'g

(

yv

/N

,e N; 1g, g.;

j/lN

/

2

\\ j'

/

/

E

/

d

/

, /'

c:

o 001OG b'O

\\

1,c3

/

\\

,/

)

- /

N/

N f.

^,,~

~

c, w

a - _,.

.a

.a a_

~

o is n ee s

a P00R ORIGlhAL FLii'. 0D - SE C.

'