f ":09 y

- jo,,

UN.TED STATES NUCLEAR REGULATORY COMMISSION e

a t

l WASHINGTON. D. C. 20555 f

FEB 2 0 991 1

Docket No. 50-213 LS05-81-02-039 Mr. W. G. Counsil, Vice President Nuclear Engineering and Operations Connecticut Yankee Atomic Power Co.

Post Office Box 270 Hartford, Connecticut 06101

Dear Mr. Counsil:

SUBJECT:

HADOAM NECK - SEP TOPIC VI-7.A.1, ECCS REEVALUATION TO ACCOUNT FOR INCREASED VESSEL UPPER HEAD TEMPERATURE The safety objective of this topic is to ensure that correct upper head temperatures were used in the loss-of-coolant-accident (LOCA) analysis.

Originally, LOCA analyses for all Westinghouse reactors were conducted assuming that the temperature of the water in the upper head region of the reactor vessel was the same as the inlet water temperature because of a bypass flow from the downcomer to the upper head. Temperature measurements made by Westinghouse indicate that the actual temperature of the upper head fluid is almost as high as the hot let (outlet) temperature. All operating reactors were required to resubmit LOCA analyses using hot leg temperature for the upper head volume.

The staff's safety evaluation of Amendment No. 21 to Facility License No. DPR-61, dated October 22, 1977, accepted revised analyses with upper head fluid temperature equal to the hot leg (outlet) temperature.

Since this approved analysis satisfies the safety objective of SEP Topic VI-7.A.1, this topic is considered to be complete. This letter is provided only to document topic status; no response is required.

Sincerely, Dennis M. Crutchfield, hief Operating Reactors Branch #5 Division of Licensing

$ ol 6

cc: See next page 3

/

w o a.c 0226n

Mr. W. G. Counsil HADDAM NECK PLANT DOCKET NO. 50-213 cc Day, Berry & Howard U. S. Environmental Protection Counselors at Law Agency One Constitution Plaza Region I Office Hartford, Connecticut 06103 ATTN: EIS C0ORDINATOR JFK Federal Building Superintendent Boston, Massachusetts 02203 Haddam Neck Plant RFD #1 Resident Inspector Post Office Box 127E Haddam Neck Nuclear Power Station East Hampton, Connecticut 06424 c/o U. S. NRC East Haddam Post Office Mr. Janes R. Himmelwright East Haddam, Connecticut 06423 Northeast Utilities Service Company P. O. Box 270 Hartford, Connecticut 06101 Russell Library 119 Broad Street Middletown, Connecticut 06457 Board of Selectmen Town Hall Haddam, Connecticut 06103 Connecticut Energy Agency ATTN: Assistant Director Research and Policy Development Department of Planning and Energy Policy 20 Grand Street Hartford, Connecticut 06106 i

Director, Technical Assessnent i

Division l

Office of Radiation Prograns l

(AW-459) l U. S. Environmental Protection Agency Crystal Mall #2 i

Arlington, Virginia 20460 l

I.

~

L I

l_-

.