MONTHYEARML20117L4591986-05-0909 May 1986 Responds to Re Response of micro-R Meter to Spectrum of Gamma Rays Monitored in Course of Final Survey & Initial Survey Measurements in Exposure Room,Resolution of Geometrical Impact on Observations ML20141E8651986-04-0404 April 1986 Forwards Decommissioning Insp Rept 50-187/85-02 on 851230-860124.No Violations Noted.Agreement on Proper Disposition of Matl Must Be Obtained from NRR ML20140G7051986-03-27027 March 1986 Lists Change in Telephone Number for H Bernard,Facility Project Manager,Due to NRR Reorganization.D Tondi New Nonpower Reactors & Safeguards Licensing Section Leader. Correspondence Should Be Sent to Listed Address ML20154J2111986-02-28028 February 1986 Requests Addl Info Re Reactor Decommissioning Program, Including Calibr Methods & Stds for Sodium Iodide Crystal Survey Instrument & Calculations & Survey Measurements of Exposure Room ML20205J9801986-02-17017 February 1986 Forwards Statistical Info Re Redistribution of Concrete Rubble Stored in fenced-off Area of Parking Lot,Per Request. Net Radiation Level Above Background Below NRC Criterion. Higher Readings Recorded When Ground Dry ML20137T8461986-02-0707 February 1986 Discusses Billing of Fee for 850114 Application for Decommissioning Facility Under License R-90.Data for Applications in Categories 3-5 Not Received ML20214C7191986-02-0505 February 1986 Discusses Amount of Induced Activity Remaining in Concrete Biological Shield for facility.Twenty-two Metric Tons of Activated Concrete,Containing 0.55 Mci Neutron Induced Activity,Remain on Site,Per Nov 1985 Rept ML20138P4311985-12-13013 December 1985 Forwards Decommissioning Program Final Rept Per 850114 Decommissioning Plan Submittal.Radwaste Taken to Hanford for Disposal ML20154S0931985-11-26026 November 1985 Forwards Proprietary Natural Radioactivity Survey, Sept 1984 - Aug 1985. Encl Withheld ML20137M0291985-11-20020 November 1985 Requests Approval to Dispose of Approx 1,000 Metric Tons of Concrete Biological Shielding from Facility.Proposed Disposal Will Be by Burial in Soil at Local Landfill ML20137Q3171985-09-0404 September 1985 Requests Permission to Proceed W/Plans to Demolish Facility Biological Shield,Bury Concrete Rubble at Local Landfill & Survey Floor/Ground Area Where Shielding Structure Stands, Pending State of CA Approval ML20127N7891985-06-24024 June 1985 Forwards Order Authorizing Dismantling & Disposition of Northrop Triga Reactor,Finding of No Significant Impact, Safety Evaluation & Environ Assessment ML20128A1141985-05-15015 May 1985 Forwards 850515 Fr Notice of Proposed Issuance of Orders Authorizing Disposition of Component Parts & Terminating Facility License,In Accordance w/850114 Application ML20127G0651985-05-10010 May 1985 Requests Payment of Fee for 850114 Application for Review of Decommissioning Plan & Environ Rept ML20128C3951985-05-0303 May 1985 Forwards Insp Rept 50-187/85-01 on 850408-09.No Noncompliance Noted ML20117A7681985-04-29029 April 1985 Requests Approval to Proceed W/Certain Maint Tasks Prior to Approval of Decommissioning Plan & Dismantling of Reactor Facility.Tasks Include:Removing Control Rod & Drive mechanism,in-core Instrumentation & Vacuum Sys ML20115F7651985-04-0909 April 1985 Responds to Request for Addl Info Re Decommissioning Plan. Surface Contamination Will Be Monitored W/Suitable Alpha, Beta & Gamma Sensitive Instruments ML20104A5931985-01-15015 January 1985 Forwards Amended Transportation Routes Per Univ of Illinois Request.Possible Combination of Manhattan,Ks & Urbana,Il Route Discussed W/B Hawkins.Early Approval Requested ML20112H4551985-01-14014 January 1985 Forwards Proprietary Northrop Triga Reactor Facility Environ Rept in Support of Decommissioning Plan & Proprietary Northrop Triga Reactor Facility Decommissioning Plan. Reactor Shut Down on 841221.Repts Withheld ML20093A3891984-07-0303 July 1984 Advises of Decision to Decommission Northrop Triga Reactor. Dismantling Plan Will Be Submitted in Sept 1984 ML20069E5141983-03-14014 March 1983 Forwards Natural Environ Radioactivity Survey for Period Sept 1981 - Aug 1982 ML20028F9921983-01-24024 January 1983 Responds to NRC 821124 Ltr Re Violations Noted in IE Insp Rept.Corrective Actions:Procedures Written & Approved for Calibr of Area Radiation & Air Particulate Monitors ML20066G7781982-11-16016 November 1982 Forwards Physical Security Plan.Plan Withheld (Ref 10CFR2.790) ML20066C4941982-11-0101 November 1982 Forwards Public Version of Emergency Plan ML20069P6031982-10-29029 October 1982 Forwards Natural Environ Radioactivity Survey for Period of Sept 1981-Aug 1982 ML20062H5921982-07-27027 July 1982 Forwards IE Insp Rept 50-187/82-01 on 820628-30 & Notice of Violation ML20054L3881982-06-16016 June 1982 Ltr to All Research & Test Reactor Licensees Requesting That Reg Guide 2.6 (for Comment) & ANSI/ANS-15.16 (Draft II Dtd 811129) Be Used to Meet Requirement of Final Amend to 10CFR50.54(r) Re Emergency Planning.Fr Notice Encl ML19347E6041981-05-0808 May 1981 Requests Matls & Facility Licenses for Research Reactor ML20003B9651981-01-26026 January 1981 Responds to NRC 801230 Ltr Re Violations Noted in IE Insp Rept 50-187/80-02.Corrective Actions:Performed & Documented Systematic Performance Evaluations for Licensed Reactor Supervisor as Required ML19340C7331980-11-26026 November 1980 Forwards Natural Environ Radioactivity Survey,Sept 1979 - Aug 1980. ML19353A1541980-11-0606 November 1980 Responds to NRC 801016 Ltr Re Violations Noted During IE Insp on 800924.Corrective Actions:Annual Exposure Repts for 1978 & 1979 Submitted as Required & More Systematic Screening of Fr Implemented ML19338G6531980-10-23023 October 1980 Informs NRC That License R-90 Should Not Be on Us List of IAEA Eligible Facilities.Company Does Work Which Has Direct Natl Security Significance ML20149K1911980-05-0707 May 1980 Generic Ltr 80-38 to All Nonpower Reactor Licensees Re NPR Physical Protection Requirements.Summary of Certain NPR Physical Protection Requirements Encl & Should Aid in Determining Safeguards Requirements Applicable to Facility ML19254F4981979-11-0202 November 1979 Forwards Executed Amend 14 to Indemnity Agreement B-26 ML19260A1891979-10-26026 October 1979 Forwards Natural Environ Radioactivity Survey Sept 1978- Aug 1979. ML19207A8191979-08-16016 August 1979 Forwards Endorsement 13 to Indemnity Agreement B-26 ML20132A9521979-08-14014 August 1979 Forwards IE Info Notice 79-20, NRC Enforcement Policy - NRC Licensed Individuals. No Action Required ML20062E9971978-12-0101 December 1978 Ack Receipt of Informing NRC of Steps Taken to Correct Deviations Noted in Inspec Rept 50-187/78-03 ML20062F0021978-11-14014 November 1978 Responds to 781030 NRC Ltr Re Deviation Noted in Inspec Rept 50-187/78-03.Corrective Actions: Establishes Calendar of Periodic Maint,Reinstates Prog of Periodic & Systematic Performance Eval of Lic Individuals,Emerg Procedure Review ML20062F0071978-10-30030 October 1978 Forwards Inspec Rept 50-187/78-03 on 781012-1013 & Assoc Notice of Violation ML20062B9301978-10-17017 October 1978 Forwards Natural Environ Radioactivity Survey for Sept 1977-Aug 1978 ML20062C7831978-10-0505 October 1978 Notifies NRC of Personnel Changes at Northrop Reactor Facil ML20137G4721971-06-23023 June 1971 Advises That Presence & Irradiation of Explosives in Reactor Must Be Evaluated Due to Potential for Damage to Reactor. Evaluation Requested Establishing Operating Restrictions,Max Quantity of Explosives Allowed in Facility & Form 1986-05-09
[Table view] Category:INCOMING CORRESPONDENCE
MONTHYEARML20117L4591986-05-0909 May 1986 Responds to Re Response of micro-R Meter to Spectrum of Gamma Rays Monitored in Course of Final Survey & Initial Survey Measurements in Exposure Room,Resolution of Geometrical Impact on Observations ML20205J9801986-02-17017 February 1986 Forwards Statistical Info Re Redistribution of Concrete Rubble Stored in fenced-off Area of Parking Lot,Per Request. Net Radiation Level Above Background Below NRC Criterion. Higher Readings Recorded When Ground Dry ML20214C7191986-02-0505 February 1986 Discusses Amount of Induced Activity Remaining in Concrete Biological Shield for facility.Twenty-two Metric Tons of Activated Concrete,Containing 0.55 Mci Neutron Induced Activity,Remain on Site,Per Nov 1985 Rept ML20138P4311985-12-13013 December 1985 Forwards Decommissioning Program Final Rept Per 850114 Decommissioning Plan Submittal.Radwaste Taken to Hanford for Disposal ML20154S0931985-11-26026 November 1985 Forwards Proprietary Natural Radioactivity Survey, Sept 1984 - Aug 1985. Encl Withheld ML20137M0291985-11-20020 November 1985 Requests Approval to Dispose of Approx 1,000 Metric Tons of Concrete Biological Shielding from Facility.Proposed Disposal Will Be by Burial in Soil at Local Landfill ML20137Q3171985-09-0404 September 1985 Requests Permission to Proceed W/Plans to Demolish Facility Biological Shield,Bury Concrete Rubble at Local Landfill & Survey Floor/Ground Area Where Shielding Structure Stands, Pending State of CA Approval ML20117A7681985-04-29029 April 1985 Requests Approval to Proceed W/Certain Maint Tasks Prior to Approval of Decommissioning Plan & Dismantling of Reactor Facility.Tasks Include:Removing Control Rod & Drive mechanism,in-core Instrumentation & Vacuum Sys ML20115F7651985-04-0909 April 1985 Responds to Request for Addl Info Re Decommissioning Plan. Surface Contamination Will Be Monitored W/Suitable Alpha, Beta & Gamma Sensitive Instruments ML20104A5931985-01-15015 January 1985 Forwards Amended Transportation Routes Per Univ of Illinois Request.Possible Combination of Manhattan,Ks & Urbana,Il Route Discussed W/B Hawkins.Early Approval Requested ML20112H4551985-01-14014 January 1985 Forwards Proprietary Northrop Triga Reactor Facility Environ Rept in Support of Decommissioning Plan & Proprietary Northrop Triga Reactor Facility Decommissioning Plan. Reactor Shut Down on 841221.Repts Withheld ML20093A3891984-07-0303 July 1984 Advises of Decision to Decommission Northrop Triga Reactor. Dismantling Plan Will Be Submitted in Sept 1984 ML20069E5141983-03-14014 March 1983 Forwards Natural Environ Radioactivity Survey for Period Sept 1981 - Aug 1982 ML20028F9921983-01-24024 January 1983 Responds to NRC 821124 Ltr Re Violations Noted in IE Insp Rept.Corrective Actions:Procedures Written & Approved for Calibr of Area Radiation & Air Particulate Monitors ML20066G7781982-11-16016 November 1982 Forwards Physical Security Plan.Plan Withheld (Ref 10CFR2.790) ML20066C4941982-11-0101 November 1982 Forwards Public Version of Emergency Plan ML20069P6031982-10-29029 October 1982 Forwards Natural Environ Radioactivity Survey for Period of Sept 1981-Aug 1982 ML19347E6041981-05-0808 May 1981 Requests Matls & Facility Licenses for Research Reactor ML20003B9651981-01-26026 January 1981 Responds to NRC 801230 Ltr Re Violations Noted in IE Insp Rept 50-187/80-02.Corrective Actions:Performed & Documented Systematic Performance Evaluations for Licensed Reactor Supervisor as Required ML19340C7331980-11-26026 November 1980 Forwards Natural Environ Radioactivity Survey,Sept 1979 - Aug 1980. ML19353A1541980-11-0606 November 1980 Responds to NRC 801016 Ltr Re Violations Noted During IE Insp on 800924.Corrective Actions:Annual Exposure Repts for 1978 & 1979 Submitted as Required & More Systematic Screening of Fr Implemented ML19338G6531980-10-23023 October 1980 Informs NRC That License R-90 Should Not Be on Us List of IAEA Eligible Facilities.Company Does Work Which Has Direct Natl Security Significance ML19254F4981979-11-0202 November 1979 Forwards Executed Amend 14 to Indemnity Agreement B-26 ML19260A1891979-10-26026 October 1979 Forwards Natural Environ Radioactivity Survey Sept 1978- Aug 1979. ML19207A8191979-08-16016 August 1979 Forwards Endorsement 13 to Indemnity Agreement B-26 ML20062F0021978-11-14014 November 1978 Responds to 781030 NRC Ltr Re Deviation Noted in Inspec Rept 50-187/78-03.Corrective Actions: Establishes Calendar of Periodic Maint,Reinstates Prog of Periodic & Systematic Performance Eval of Lic Individuals,Emerg Procedure Review ML20062B9301978-10-17017 October 1978 Forwards Natural Environ Radioactivity Survey for Sept 1977-Aug 1978 ML20062C7831978-10-0505 October 1978 Notifies NRC of Personnel Changes at Northrop Reactor Facil 1986-05-09
[Table view] Category:RESEARCH INSTITUTION/LABORATORY TO NRC
MONTHYEARML20112H4551985-01-14014 January 1985 Forwards Proprietary Northrop Triga Reactor Facility Environ Rept in Support of Decommissioning Plan & Proprietary Northrop Triga Reactor Facility Decommissioning Plan. Reactor Shut Down on 841221.Repts Withheld ML20003B9651981-01-26026 January 1981 Responds to NRC 801230 Ltr Re Violations Noted in IE Insp Rept 50-187/80-02.Corrective Actions:Performed & Documented Systematic Performance Evaluations for Licensed Reactor Supervisor as Required ML19353A1541980-11-0606 November 1980 Responds to NRC 801016 Ltr Re Violations Noted During IE Insp on 800924.Corrective Actions:Annual Exposure Repts for 1978 & 1979 Submitted as Required & More Systematic Screening of Fr Implemented ML19260A1891979-10-26026 October 1979 Forwards Natural Environ Radioactivity Survey Sept 1978- Aug 1979. 1985-01-14
[Table view] |
Text
, - {'
327-81-02
/
, qNIUII7N
- g. q %
January 26, 1931 f9 * <f' 9 5!
k S hqdkp $h U.S. I!ucigar Regulatory Comission
.segion s w/g, gg 1990 :1. California Boulevard Suite 202, Walnut Creek Plaza Walnut Creek, California 94596 Attention: ,1 L. Crews, Chief Reactor Operations and fluclear Support Branch
Reference:
Docket tio. 50-187 Gentl e.nen :
Pursuant to tne provisions of Section 2.201, of the flRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations. Section 2.201 requires us to submit to your office, within twenty-five (25) days of the date of your notice, a written statement or explanation in reply including (1) corrective steps wnich have been taken by us and the resuits acnieved; (2) corrective steps which will be taken to avoid further violations; and (3) che date when full compliance will be aclieved.
Contrary to the requirenents of 10 CFR 50, Paragraph 50.G4 (i-1),
the periodic and systematic performance evaluations for the licensed Reactor Supervisor had not been performed and not documented as re-ouired by Paragraph VII of the liRC approved Operator Requalification Training Program.
(1) Corrective steps which have been taken and results achieved; Systemtic performance evaluations for the licensed Reactor Supervisor has been performed and documented as required.
(2) Corrective steps which were taken to void further violations; Periodic file system has been established to review the status of all Heactor personnel's training and performance evaluations.
(3) Date when full compliance was achieved was January 13, 1981.
If you should have any questions concerning this letter, please contact the undersigned.
M -W[g -- -
- 2 Walter E. Crandall, Chairman Corporate Radiation Committee N ortheop Cos porarmn . Enht op De,wt h .ind Technutoqy Ccater . One lhear, h Pyk e Palos Verdes Peninsula, Cahf. 90274