t 1
y s*
- h L,--*
w f.;
UNITED STATES y
y et g
NUCLEAR REGULATORY COMMISSION
'E W A$MINGTON, D. C. 20656 t
~h/
LS05-80-12-035 Cg!j'j c
:,,, p s '., l' 2y LETTER FOR ALL SEP LICENSEES
SUBJECT:
GUIDELINES FOR SEP SOIL-STRUCTURE INTERACTION REVIEWS Enclosed for four information are guidelines for rarforning soil-structure interaction reviews for SEP facilities. Also inciided is a simplified analytical approach for evaluating the effects of ; oil-structure interaction using a lumped parameter model. The simplified aparcach presented does not preclude the use of other procedures which wesid be reviewed and approved on a case-by-case basis.
Sincerely, Dennis M. Cratch end, C f
Operating Reactors Branc #5 Division of Licensing
Enclosure:
SSRT Guidelines for SEP Soil-Structure Interaction Review cc: See next page G
.:7 3
e 1
.=
1 m
b l
l l
81020304ilP
s g
Mr. W. G. Counsil MILESTONE NUCLEAR HADDAM NECK PLANT POWER STATION, DOCKET NO. 50-213 UNIT N0. 1 DOCKET NO. 50-245 cc William H. Cuddy, Esquire Connecticut Energy Agency Day, Berry & Howard ATTN: Assistant Director Counselors at Law Research and Policy One Constitution Plaza Development Hartford, Connecticut 06103 Department of Planning and Energy Policy Board of Selectmen 20 Grand Street Town Hall Hartford, Connecticut 06106 Haddam, Connecticut 06103 Director, Technical Assessment Division Northeast Nuclear Energy Company Office of Radiation Programs ATTN: Superintendent (AW-459)
Millstone Plant U. S. Environmental Protection P. O. Box 128 Agency Waterford, Connecticut 06385 Crystal Mall #2 Arlington, Virginia 20460 Mr. James R. Hinmelwright Northeast Utilities Service Company U. S. Environmental Protection P. O. Box 270 Agency Hartford, Connecticut 06101 Region I Office ATTN: EIS COORDINATOR Resident Inspector JFK Federal Building c/o U. S. NRC Boston, Massachusetts 02203 P. O. Box Drawer KK Niantic, Connecticut 06357 Superintendent Haddam Neck Plant Waterford Public Library RFD #1 l
Rope Ferry Road, Route 156 Post Office Box 127E Waterford, Connecticut 06385 East Haspton, Connecticut 06424 First Selectman of the Town Resident Inspector of Waterford Haddam Neck Nuclear Power Station Hall of Records c/o U.S. NRC 200 Boston Post Road East Haddam Post Office Waterford, Connecticut 06385 East Haddam, Connecticut 06423 John F. Opeka Systers Superintendent Mr. W. G. Counsil, Vice President Northeast Utilities Service Company Nuclear Engineering and Operations P. 0.-Box 270 Connecticut Yankee Atomic Power.Co.
Hartford, Connecticut 06101 Post Office Box 270 Hartford, Connecticut 06101 Mr. Richard E. Schaffstall, Executive Director 17 15th St eet N Washington, D. C.
20005 for SEP Owners Group l
1747 Pennsylvania Avenue, NW Washington, D.C.
20006
+
we y
c
's NATHAN M.
NEWMARK CONSULTING ENGINEERING SERYlCES 1211 CIVIL ENGINEERING SUILDING URBANA. ILLINCIS 618Q1 8 December 1980 Mr. William T. Russell, Chief Systematic Evaluation Pregram Branch Division of Licensing Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Connission Washington, D. C. 20555 (Mail Stop 516)
Re: SSRT Guidelines for SEP Soil-Structure Interaction Review Contract NRC-03-78-150
Dear Mr. Russell:
The Guidelines for SEP Soil-Structure Interaction Review, as prepared by the Senior Seismic Review Team, are trans-mitted harewith with signature approval.
We are appreciative of the help of the many individuals' who contributed to the preparation of these guidelines.
Sincerely yours, I
't, %, M N. f1. Newmark l
Chairman, SSRT i
dp Enclosure Distribution:
W. T. Russell - 2 l
T. Cheng - 1 N. M. Newmark - 2 W. J. Hall - 1 l
R. P. Kennedy - 1 l
R. Murray - 1 J.J.Stevenson-1 6
e 1
l
'!5 L
E E
..I.
$4\\
l h b$I IC$"[
p m
-801:110W g/SC.
f
_ -