ML20002C893

From kanterella
Jump to navigation Jump to search
Forwards Reactor Containment Bldg Integrated Leak Rate Test, Performed in Sept 1980
ML20002C893
Person / Time
Site: Yankee Rowe
Issue date: 01/06/1981
From: Kay J
YANKEE ATOMIC ELECTRIC CO.
To: Harold Denton
Office of Nuclear Reactor Regulation
Shared Package
ML20002C894 List:
References
FYR-81-3, NUDOCS 8101120293
Download: ML20002C893 (1)


Text

-

YANKEE ATOMIC ELECTRIC COMPANY

-m.

-. 4 y._

1671 Worcester Road, framingham, Massachusetts 01701 B.3.2.1 YANKEE N

FYR 81-3 January 6, 1981 U.S. Nuclear Regulatory Commission Washington, D.C 20555 Attention:

Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation

Reference:

(a) License No. DPR-3 (Docket No.50-29)

Subject:

Reactor Containment Building Integrated Leak Rate Test

Dear Sir:

Enclosed is our report " Reactor Containment Building Integrated Leak Rate Test" which summarizes the test performed in September,1980.

This report.

provides the evaluation of the Type A test results and a summary analysis of l

periodic Type B and Type C tests that were performed since the last Type A test in accordance with the requirement of 10CFR50, Appendix J, paragraph I

V.3 3 If you have any questions or desire additional information, please contact us.

Very truly yours, YANKEE ATOMIC ELECTRIC COMPANY

. A. Kay Senior Engir er - Licensing IT JAK/kab S 3 31/,E E ! ',

Enclosure 00 Of Fil ElinT1951 w;; g N0linWulsi 8102120 M p

1 1

L