Advises That Written Response Is Required to IE Bulletin 80-23, Failures of Solenoid Valves Mfg by Valcor Engineering Corp. First Paragraph Erroneously Stated No Written Response Required
ML20002B727
Person / Time
Site: Crane  Constellation icon.png
Issue date: 11/19/1980
From: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Arnold R
METROPOLITAN EDISON CO.
References
NUDOCS 8012220651
Download: ML20002B727 (1)


Text

_

l D' a rrev

[m

'o UNITED STATES

  1. (f'7,7, NUCLEAR REGULATORY COMMISSION J.'.,E

$ ', V [o REGION I 0,

g 631 PARK AVENUE KING OF PRUSSIA. PENNSYLVANIA 19406 Dockbt*M8s. 50-289 50-320 November 19, 1980 Metropolitan Edison Company ATTN:

Mr. R. C. Arnold Senior Vice President 100 Interpace Parkway Parsippany, New Jersey 07054 Gentlemen:

Inspection and Enforcement Bulletin No. 80-23 was transnitted to you for action by letter dated November 14, 1980.

The first paragraph erroneously stated, "No written response is required."

It should have stated, "A written response is required."

Sincerely,

[VW#-

L yce H. Grier ctor l

CC:

H. D. Hukill, Director, TMI-l J. G. Herbein, Director - Nuclear Assurance E. G. Wallace, Licensing Manager R. J. Toole, Manager, Unit 1 J. J. Colitz, Manager, Plant Engineering, Unit 1 J. J. Barton, Manager Site Operations, Unit 2

8. Elam, Manager, Plant Engineering, Unit 2 R. F. Wilson, Director - Technical Functions L. W. Harding, Supervisor of Licensing G. K. Hovey, Director, Unit 2 I. R. Finfrock, Jr.

R. W. Conrad J. B. Lieberman, Esquire G. F. Trowbridge, Esquire Ms. Mary V. Southard, Chairperson, Citizens for a Safe Environment i

.