I REGil.AT0ff DOCKET RLE CO?Y U-0200
~
/LLINDIS POWER COMPANY
[
Q37-80(11-12%-6 500 SOUTH 27TH STREET, DECATUR ILLINOIS 62525 November 12, 1980 Mr.-Gaston Fiorelli, Chief Reactor Construction and Engineering Support Branch U.S. Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137
Dear Mr. Fiorelli:
This is in response to your letter dated October 7, 1980, which included a Notice of Violation and Inspection Report Number 50-461/80-19.
The one item of noncompliance cited in this report states in part:
" Contrary to the above, activities affecting quality were not in accordance with the appropriate instructions, in that completed travelers did not contain the welder's identification and the weld material Heat / Lot Number as required by BTS 402."
Paragraph 6.2.1 of BTS 402, Weld Control, was intended to provide unique traceability of welding materials and welder identification for ASME-related work only.
Specific Corrective Action is being taken to revise BTS 402, Paragraph 6.2.1, to differentiate between the various classes of
- work, i.e., ASME, Safety-Related (Non-ASME), etc.,
and to clarify the filler metal and welder identification documentation require-ments of each classification.
In the future, procedures will be written in such a way to prevent misinterpretation of the procedure.
l It was demonstrated during the inspection that traceability for the l
filler material in structural weldments could be developed to show that one of several certified heats of filler material was used in a particular weld.
However, it was not possible to always identify the specific filler material in a specific structural weld even though it could be demonstrated that only certified heats are used MOV 17 Ea0 l
_y
,-=.-i
~.
U-0200 Gaston Fiorelli C 37-80 (11-12 ) -6 November 12, 1980 Page 2 on safety-related work.
Secondly, Baldwin Associates Technical Services Department personnel monitor all safety-related structural welding to verify welder and weld material certification.
It is believed that this corrective actica will adequately avoid future noncompliances of this nature and full compliance should be achieved by the end of the year.
I trust that the above actions constitute an acceptable response and will satisfactorily complete our Corrective Action.
Sincerely,
/
L... Koch Vice President cc:
H.
H. Livermore, NRC Resident Inspector Director-Quality Assurance i
..