ML20002B214
| ML20002B214 | |
| Person / Time | |
|---|---|
| Site: | Framatome ANP Richland |
| Issue date: | 11/28/1980 |
| From: | Norderhaug L NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V) |
| To: | Nilson R SIEMENS POWER CORP. (FORMERLY SIEMENS NUCLEAR POWER |
| Shared Package | |
| ML20002B215 | List: |
| References | |
| NUDOCS 8012110100 | |
| Download: ML20002B214 (2) | |
Text
.[paa8%q'o,,
UNITED STATES
~
NUCLEAR REGULATORY COMMISSION o
{
,I -.
REGION V g
1990 N. CALIFORNIA 800LEVARD o,%
,e SulTE 202. WALNUT CREEK PLA2A
- ,,,e WALNUT CREEK. CALIFORNIA 94508 1
November 28, 1980 5
1 a
Docket Nr. 70-1257 5
'b-E o
Exxon Nuclear Company Inc.
2955 George Washington Way Richland, Washington 99352 Attention:
Dr. R. Nilson Corporate Licensing and Compliance Gentlemen:
~'-is letter refers to the routine safeguards inspection of your activities authorized under NRC License No. SNM-1227 conducted by Messrs. B. Brock, Y. Kobori and A. Wieder of this office and H. Werner of NRC-HQ on September 25 - October 3 and October 27-30, 1980.
It also refers to the discussion of our inspection findings held by the inspectors with Mr. L. Hansen and other members of management and staff on October 3 and October 30, 1980.
The inspection included examination of activities related to your program for the control and accounting of special nuclear material in accordance with applicable requirements of Title 10, Code of Federal Regulations, Part 70, " Domestic Licensing of Special Nuclear Material",
and pertinent license conditions as described in the enclosed inspection report. Within these areas, the inspection consisted of selective examinations of procedures and records, interviews with facility personnel and observations by the inspectors.
Based on the results of this inspection it appears that one of your activities was not conducted in full compliance witti NRC requirements, as set forth in the Not1ce of Violation, enclosed herewith as Appendix A.
Pursuant to the provisions of 10 CFR 2.201 you are required to respond as indicated in Appendix A.
In accordance with Section 2.790(d).of the NRC's " Rules of Practice,"
Part 2, Title 10, Code of Federal Regulations, documentation of findings of your safeguards and security procedures are exempt from disclosure; 80121)0100 f'
pp.
gy 2 s 1980-Exxon Nuclear _ Company Inc. therefore, the~ enclos Jre(s)' to' this ' letter, the inspection report, and
'your. response-to' the item (s) listed in the enclos:;*e(s) to this letter will:not be placed-in the.Public Document Room and will receive limited tdistribution.
Should you1have any questions concerning this letter, we will-be. glad to dhcuss them 'with you.
Sincerely, f
y/ '
pvf K
/, s
)
L. - R.
lor erhau p Chief, Safegu dds Branch
\\
Enclosures:
1.
Appendix A - Notice of Violation 2.-
. Inspection Report No.70-1257/80-08(IE-V-408) t i
1 4
1 '
l..
S 4
g.
~
-