Notice of Violation from Insp on 800630-0801
ML20002A954
Person / Time
Site: Seabrook 
Issue date: 09/03/1980
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML20002A948 List:
References
50-443-80-07, 50-443-80-7, NUDOCS 8012090240
Download: ML20002A954 (1)


Text

-.

- ()

APPENDIX A

, NOTICE OF VIOLATION Public Service Company of New Hampshire Docket No. 50-443 This refers to the inspection conducted by the resident inspector assigned to the Seabrook Station, Units 1 and 2, Seabrcok, New Hampshire, of activities authorized by NRC License No. CPPR-135.

During this inspection, conducted June 30-August 1.1980, the following apparent item of. noncompliance was identified:

10 CFR 50. Appendix B, Criterion XV states, in part, that:

" Nonconforming items shall be reviewed and accepted, rejected, repaired, or reworked in accordance with documented procedures."

The Seabrook Station PSAR for Units 1 and 2 states, in part, in paragraph 17.1.15 that:

"Each organization performing quality related activities covered by this program shall provide measures to prevent inadvertent use or installation of material. parts or components which do not conform to the applicable requirements."

Pullman Power Products Document No. XV-2, Revision 6, requires that a non-conformance report be initiated for, among other things, evidence of a special process out of control and that the items involved be segregated and a " Hold Tag" placed on them.

2 1

Contrary to the above, on July 10, 1980, several embed plates, with marked evidence of stud weld conditions at variance with AWS D1.1 requirements, were identified with " Accept Tags" and located in the field apparently ready for installation.

Neither contractor nor vendor documentation was available to substantiate that the nonconforming condition had been reviewed, properly dispositioned,.and ultimately accepted.

This item is an infraction applicable to Docket Number 50-443.