Text

b j

,, c. t rm P E T' ry.

g.g -

i-I Westinghouse orausa

(

Electric Corporation -

3 {.g] gg All 14 comsmcamma October 2, 1980 i

U. S. Nuclear Regulatory Commission i

ATTN:

Mr. W. B. Kenna, Chief Safeguards Dranch 101 Marietta Street, Suite 3100, Atlanta, Georgia 30303 RE: RII:DWJ 70-1151/80-21 Gentlemen:

In response to your letter of August 29, 1980, concerning your inspection of our facilities conducted July 21-25, 1980, and pursuant to the provisions of Section 2.201 of the NRC's " Rules of Practice", Part 2, Title 10, Code of Federal Regulations, Westinghouse comments are transmitted herewith as Appen-dix A.

This appendix should be withheld f rom public disclosure in accordance with Section 2.790(d) of the NRC's " Rules of Practice", Part 2, Title 10, Code of Federal Regulations.

t If you should have any questions regarding this matter, please write to Mr. H. Foster or me at.the above address, or telephone either of us on (803) 776-2610.

Sincerely, i

I WESTINGHOUSE ELECTRIC CORPORATION

{,

W. L. Goodwin, Manager Regulatory Compliance i

l M.

(

Me d D'Amore, Manager i

Manufacturing and Columbia Plant WLG/MD/ff

Enclosure:

Appendix A l

l 8012090