ML20002A301

From kanterella
Jump to navigation Jump to search
Responds to Util 650623 Request for Authorization of Proposed Change 65 to Tech Specs.Authorizes Use of Two Stainless Steel Clad silver-indium-cadmium Control Rods for Cladding Corrosion Resistance Evaluation
ML20002A301
Person / Time
Site: Yankee Rowe
Issue date: 07/16/1965
From: Doan R
US ATOMIC ENERGY COMMISSION (AEC)
To: Coe R
YANKEE ATOMIC ELECTRIC CO.
Shared Package
ML20002A302 List:
References
NUDOCS 8011110612
Download: ML20002A301 (1)


Text

I:-

Ro[g' Dist ribution L. FLEMENT' Document FILE COPY Formal

/

+-

UNITED STATES Supple. ntal R&P E L ading

[ l*-

WASHINGTON. D.C. 20545 S

ATOMIC ENERGY COMMISSION u

S, a

Originator: PNorian d,,,

bec: H. J. McAlduff, OR00 E. G. Case 10 M H. Shapar m amy norn ro, Docket No. 50-29 L. Kornblith (2)

E. Tremmel R. Huard C. Page P. Travelstead N. Stoner Yankee Atomic Electric Company Change No. 65 441 Stuart Street N. D. Mason

%_[

l Boston 16, Massachusetts D. Skovholt

+,

'tJ' Attention: Mr. Roger J. Coe Vice President p

-ws t Centlemen:

ing U:BIm N

This refers to your request dated June 23, 1965, for AEC authorization of Proposed Change No. 65 in the Technical Specifications of Facility License No. DPR-3 pursuant to the provisions of Section 50.59,10 CFR 50.

The proposed change would authorize the use of two stainless steel clad silver-indium-cadmium control rods to evaluate the corrosion resistance of the cladding in the berated primary coolant environment.

We have reviewed the proposed change and have found that it does not in present significant hazards considerations not described or implicit the hazards summary report, and that there is reasonable assurance that the health and safety of the public will not be endangered. A copy of our related safety evaluation is enclosed.

In view of the foregoing, pursuant to Section 50.59,10 CFR 50, Change No. 65 is hereby authorized as proposed.

Sincerely yours, C;iginal signed D1 E. G. Case L R. L. Doan, Director Division of Reactor Licensing

Enclosure:

Safety Evaluation P

jms y

a can 7/12/65 7/ /65 7//f/65

/ /65 7'/ /65

  1. "11110