ML19354D725

From kanterella
Jump to navigation Jump to search
Forwards Maint Team Insp Rept 50-458/89-04 on 890918-1017 & Notice of Violation.Weaknesses Reflected Overall Problem in Implementation of Maint Programs & Involved Performance & Documentation Errors on Part of Craftsmen
ML19354D725
Person / Time
Site: River Bend 
Issue date: 12/15/1989
From: Collins S
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Deddens J
GULF STATES UTILITIES CO.
Shared Package
ML19354D726 List:
References
NUDOCS 9001020075
Download: ML19354D725 (3)


See also: IR 05000458/1989004

Text

%

t

.e

-*

i

In Reply Refer To:

Docket: 50-45B/89-04

DEC 1 5 1989

i

Gulf States Utilities

ATTN: James C. Deddens

-

SeniorVicePresident(RBNG)

P.O. Box 220

St. Francisville Louisiana 70775

Dear Mr. Deddens:

t

SUBJECT: RIVERBENDMAINTENANCETEAt1 INSPECT 10tl(50-458/89-04)

{

'

This letter forwards the report of the maintenance team inspection (MTI)

performed by an NRC inspection team from September 18 through October 17,1989,

j

at River Bend Station. The activities involved are authorized by NRC Operating

License flPF-47 for the River Bend Station. On October 17, 1989, the MTI team

,

leader and Region IV management representatives discussed the findings with you

,

and other members of your staff at the conclusion of the inspection,

i

This maintenance team inspection was performed by the Nuclear Regulatory

Commission (NRC) to evaluate the effectiveness of maintenance activities at the

River Bend Station. The inspectors concluded that you have implemented a generally

effective maintenance program, with strengths in some areas and weaknesses in

l

others. The strengths relate to overall management control and support of

maintenance programs including the planning and scheduling elements of the

program. The weaknesses reflected an overall problem in the implementation

.

of the maintenance programs. These weaknesses involved performance and

i

documentation errors on the part of the craftsmen and reficcted poorly on the

maintenance staff's qualifications and dedication to excellence. Management's

attention is required to determine the root cause of the weaknesses and to

i

communicate their expectations for levels of performance that are commensurate

with the quality of the maintenance programs.

i

During this inspection, the inspectors found that certain of your activities

were in violation of NRC requirements. Consequently, you are required to

respond to this violation, in writing, in accordance with the provisions of

,

Section 2.201 of the NRC's " Rules of Practice," Part 2, Title 10 of the Code of

Federal Regulations. Your response should be based on the specifics contained

in the Notice of Violation enclosed with this letter.

The response directed by this letter and the acconpanying Notice is not

subject to the clearance procedures of the Office of 11anagement and Budget as

required by the Paperwork Reduction Act of 1980, PL 96-511.

  • RIV:0PS
  • C:0PS
  • C:FRPS
  • D:DRS

D:0K

JCummins/lb

JEGagliardo

BMurray

LJCallan

SJCollins

/ /89

/ /89

/ /89

/ /89

/A//f/89

  • Previously concurred

$fq

k

9001020075 091215

PDR

ADOCK 0D000450

0

PNU

, _ _ _ _

.-

\\

..

Gulf States Utilities Company

-2-

.

If you should have any questions concerning this inspection, we will be pleased

to discuss them with you.

Sincerely,

OrtDinal Signed By:

Samuel J. Collins

Samuel J. Collins, Director

Division of Reactor Projects

Enclosures:

1.

Appendix l. - Notice of Violation

2.

Appendix 11 - NRC Inspection Report

50-458/89-04 w/ Attachments

cc w/ enclosures:

'

Gulf States Utilities Company.

+

,

8

ATTN:

J. E. Booker, Manager-

River Bend Oversight

<

P.O. Box 2951

-

Beaumont, TX 77704

-

c

Conner and Wetterhahn

-

1

,

' ATTN: Troy' B. Conner, Jr. , Esq.

1747 Pennsylvania Avenue, NW

Washington, D.C.

20006

i

Gulf States Utilities Conpany

ATTH: Les England. Director

,

Nuclear Licensing

'P.O. Box 220

St. Francisville, LA 70775

Richard M. Troy, Jr., Esq.

Assistant Attorney General in Charge

State of Louisiana Department of Justice

'

234 Loyola Avenue

New Orleans, Louisiana 70112

Mr. J.-David McNeill, III

1

William G. Davis, Esq.

Department of Justice

Attorney General's Office

P.O. Box 94095

Baton Rouge, Louisiana 70804-9095

U.S. Nuclear Regulatory Commission

'ATTH:

Resident inspector

P.O.-Box 1051

St. Francisville, Louisiana 70775

m

s

s.

.%

Ia,

i

Gulf States Utilities Company

-3-

I

I'

H. Anne P1ettinger

N

3456 Villa Rose Drive

Baton Rouge, Louisiana 70806

f

President of West Feliciana

Police Jury

i

P.O. Box 1921

l

St. Francisv111e, Louisiana 70775

~r

Cajun Electric Powei Coop. Inc.

ATTN:

Philip G. Harris

L

10719 Airline Highway _

'

P.O. Box 15540

-

Baton Rouge, LA 70895

,

U.S. Nuclear Regulatory Commission

ATTN: Regional Administrator, Region IV

L

611 Ryan Plaza Drive, Suite 1000

Arlington, Texas 76011

L

Office of Environmental Affairs

ATTN: William H. Spell, Administrator

L

Nuclear Energy Division

!-

P.O. Box 14690

Baton Rouge, Louisiana 70898

'

Louisiana State University,

Government Docutients Department

s

bectoDMB(IE01)

bec distrib, by RIV:

  • DRP
  • SectionChief(DRP/C)

Lisa Shea, RM/ALF

  • HIS System
  • RPB-DRSS
  • RSTS Operator
  • ProjectEngineer(DRP/C)
  • RIV File

r

  • W.Paulson,NRRProjectManager(HS:

13-D-18)

2*DRS

-

  • J.

Cummins

  • W. Jones, RI, River Ber.d
  • J.E.Gagliardo(2)
  • R. B. Vickrey
  • D. L. Kelley
  • G. Sanborn
  • L. Ricketson

C. Hale

r

  • w/766

J