^New Hampshire m_
uc,.
Senior Vic'e President and Chief Operating Officer NYN-89163 December 15, 1989 United States Nuclear Regulatory Commission
-Washington, D.C.
20555 Attention: Document Control Desk
References:
(a) Facility Operating License NPF 67. Docket No. 50-445 (b) NHY Letter NYN-89142, dated November 6, 1989,
' Modifications to Atmospheric Steam Dump Valves.' T. C.
Feigenbaum to USNRC (c) NHY Letter NYN-89150, dated November 22, 1989,
' Request for License Amendment: Applicability for Auxiliary Feedwater System and Atmospheric Relief Valves,'
T. C. Feigenbaum to USNRC
Subject:
Withdrawal of Request for License Amendment: Applicability for Auxiliary Feedwater System and Atmospheric Relief Valves Gentlemen:
New Hampshire Yankee (NHY) submitted plans for modifying the Seabrook Station Atmospheric Steam Dump Valves via Reference (b). New Hampshire Yankee has continued to review our commitment to modify these valves and has determined that implementation of a performance monitoring program for these valves is a more prudent course of action at this time. This monitoring program will entail cycling each valve quarterly and measuring valve position and the valve actuator differential air pressure re;uired to unseat and lift the valve. The results obtained from this monitoring program will be trended to identify any degradation of valve performance and to determine the need for future corrective actions.
In Reference (c). NHY requested that the Seabrook Station Operating License (NPF-67) be revised, in part, 5 adding a note to Technical Specification 5.7.1.6 (Atmospheric Reliai Valves) to allow entry into MODE $
to perform post-modification or post-maintenance testing of these valves.
This amendment to the Technical Specifications is not required at this time due to the deferral of these modifications.
8912290137 091215 PDR ADOCK 05000443 I
P PNU New Hampshire Yonkee Division of Public Service Company of New Hampshire 50 P.O. Box 300
- Seobrook, NH 03874
- Telephone (603) 474 9521
(~.
}
4, os, I
United States Nuclear Regulatory Commission December 15, 1989 Attention: Document Control Desk New Hampshire Yankee also requested [ Reference (c)) that a similar note be added to Seabrook Station Technical Specification 3.7.1.2 (Auxiliary Feedwater System) to allow post-modification testing of the steam turbine-driven emergency feedwater pump in MODE 3.
New Hampshire Yankee has subsequently determined that the testing required to demonstrate operability of this system should entail approximately 60 hours6.944444e-4 days <br />0.0167 hours <br />9.920635e-5 weeks <br />2.283e-5 months <br /> of system unavailability.
This Technical Specification currently allows one emergency feedwater pump to be inoperable for up to 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> and allows entry into MODE 3 to perform surveillance testing of the steam turbir.e-oriven emergency feedwater pump.
The amendment to this Technical Specification which was previously requested is therefore not required.
Based on the foregoing NHY has determined that the revisions to the Seabrook Station Technical Specifications requested via Reference (c) are not required at this juncture. New Hampshire Yankee hereby withdraws the Request for License Amendment set forth in Reference (c) above.
The State of New Hampshire has been notified of the withdrawal pursuant to 10CTR50.91.
If you have any questions regarding this request, please contact Mr.
Terry L. Harpster, Director of Licensing Services, at (603) 474-9521 extension 2765.
Very truly yours, h fh k' fA Ted C. Feigenbaum
V l
L i
r,
g 7
.+,,
i 4
,{L I
United States Nuclear Regulatory Commission-December 15, 1989
[
Attention: Document Control Desk
}
r cci Mr. William T. Russell l
Regional Administrator United States Nuclear Regulatory Commission Region I 475 Allendale Road King of Prussia, PA 19406 l
t Mr. Victor Noroes. Project Manager I
Project Directorate I-3 United States Nuclear Regulatory Commission i
Division of Reactor Projects Washington, DC 20555 i
Mr. George L. Iverson, Director f
Office of Emergency Management State Office Park South 107 Pleasant Street Concord, NH 03301 Mr. Antone C. Corne NRC Senior Resident Inspector P.O. Box 1149 Seabrook, NH 03874 t
a 4
1 t
-,n, n
a..
..n....
,n--
e n
.