ML19353A154

From kanterella
Jump to navigation Jump to search
Responds to NRC Re Violations Noted During IE Insp on 800924.Corrective Actions:Annual Exposure Repts for 1978 & 1979 Submitted as Required & More Systematic Screening of Fr Implemented
ML19353A154
Person / Time
Site: 05000187
Issue date: 11/06/1980
From: Crandall W
NORTHROP RESEARCH & TECHNICAL CENTER
To: Book H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
Shared Package
ML19353A153 List:
References
NUDOCS 8101070306
Download: ML19353A154 (1)


Text

-rw l~D l

aA z$lF a &

0MD uln 327-n0-70

. W O

.WKDMOP

'.o'. e:' be r 6, 19 30

.5. Wucloar Reculatory Comission

' mion "

.933 N. California Boulevard Ji:2 202.

41r.ut Creek Plaza

ainut Creek, California 94596

,ttantion:

H. E. Book, Chief arnility mi 'h +cricl s afeEV dranCh Eeference:

Docket i'o. 50-187 Gentleu n:

Pursuant to the provisions of Section 2.201, of the f!RC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations.

Section 2.201 requires us to suipit to your of fice, within twenty (20) days of cur receipt of your notice, a written statement or explanation in reply inciuding (1) corrective steps t hich have been taken by us and the results achieved; (2) corrective steps which will be taken to avoin f urther violations; and (3) the date when full compliance will be achieved.

A.

10 CFP 20.407 states that all i,0C licensees shall submit annual exuosure su=ary reports for the years 1978 and 1979.

These reports were to be subaitted within the first ',uarters of calendar years 1970 and 1980.

Contrary to 10 CFR 20.407, the ennual exposure su:nnary reports for 1970 and 1979 were not submitted at the tir:'e of the inspection, t% :ter 2 ';, 1900.

(1) rarrective steps which have been taken and results achieved; cspies of required data which are on file at flRTC were sunnitted per requirements.

(2)

Ecreective steps which were taken to avoid further violations; ore systematic screening of the Federal Register has been irplemented.

(3) Date unen full con.pllance was achieved was October 20, 1980.

so

[?

If 7nu sndlid have any questions concerning this letter, please contact

?*,

thr unde rff gned.

' $0 wom E.[

D ~sz K

~

Ualter E. Crandall, Chairman y

8101070 3g Corporate Radiation Conmittee

m. 4...

..:. _,m.

_.m._ _,.

_..e.r

.e

_,e m.c m.