ML19352G604
| ML19352G604 | |
| Person / Time | |
|---|---|
| Site: | 07109215 |
| Issue date: | 12/20/2019 |
| From: | Dan Doyle Office of Nuclear Material Safety and Safeguards |
| To: | Neutron Products |
| WCAllen NMSS/DFM/STL 415.6877 | |
| Shared Package | |
| ML19352G600 | List: |
| References | |
| CoC No. 9215, EPID: L-2018-LLA-0133 | |
| Download: ML19352G604 (5) | |
Text
NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES
- 1.
- a. CERTIFICATE NUMBER
- b. REVISION NUMBER
- c. DOCKET NUMBER
- d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9215 16 71-9215 USA/9215/B(U) 1 OF 5
- 2. PREAMBLE
- a. This certificate is issued to certify that the package (packaging and contents) described in Item 5 below meets the applicable safety standards set forth in Title 10, Code of Federal Regulations, Part 71, Packaging and Transportation of Radioactive Material.
- b. This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.
- 3.
THIS CERTIFICATE IS ISSUED ON THE BASIS OF A SAFETY ANALYSIS REPORT OF THE PACKAGE DESIGN OR APPLICATION
- a.
ISSUED TO (Name and Address)
- b. TITLE AND IDENTIFICATION OF REPORT OR APPLICATION Neutron Products, Inc.
22301 Mt. Ephraim Road P.O. Box 68 Dickerson, MD 20842 Neutron Products, Inc., application dated May 1, 2018, as supplemented.
- 4. CONDITIONS This certificate is conditional upon fulfilling the requirements of 10 CFR Part 71, as applicable, and the conditions specified below.
- 5.
(a)
Packaging (1)
Model No.: NPI-20WC-6 MkII (2)
Description A steel encased, lead shielded cask contained within a wooden overpack with a steel outer shell. The cask is 24 inches in diameter with a 3/8-inch thick steel spherical shell and a cavity formed by an 8-1/4-inch ID by 3/16-inch thick steel tube. Positive closure of the shielded cask is accomplished by bolted end covers at each end of the cavity. The overpack outer diameter, including the flanges which secures the lid to the body and the tie downs brackets, is approximately 55 inches in diameter. The overpack height, including the lid lifting eye and the base support structure, is approximately 59 inches. The maximum package gross weight is 6,000 pounds.
(3)
Drawings The Model No. NPI-20WC-6 MkII packaging is constructed in accordance with Neutron Products, Inc., Drawing Nos. 240116, Rev. J; and 240122, Sheet 1 of 2, Rev. H, Sheet 2 of 2, Rev. H.
NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES
- 1.
- a. CERTIFICATE NUMBER
- b. REVISION NUMBER
- c. DOCKET NUMBER
- d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9215 16 71-9215 USA/9215/B(U) 2 OF 5
(b)
Contents (1)
Type and form of material (i)
Cobalt-60 as sealed sources which meet the requirements of special form radioactive material.
(ii)
Cesium-137 as sealed sources which meet the requirements of special form radioactive material.
(2)
Maximum quantity of material per package (i)
For contents described in 5(b)(1)(i) contained within drum assembly shown as Item 5 on Neutron Products, Inc., Drawing No. 240122, Sheet 1 of 2, Rev. H:
(a) Maximum decay heat not to exceed 240 watts.
(b) Maximum activity not to exceed 15,000 curies provided all the following conditions are met:
At least 6 inches of full-diameter, axial shielding between the source and each shipping/transfer cask (S/TC) cover. Stainless steel, lead, or tungsten alloy may be used for 2 inches of shielding nearest the S/TC covers, with the remaining axial shielding provided by tungsten alloy.
The source is centered within the drawer cavity The source is of uniform activity.
(c) For configurations that do not meet all the conditions in 5(b)(2)(i)(b), the contents shall be shown to meet the requirements in 10 CFR 71.47(b) in accordance with Procedure R-2014G.
NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES
- 1.
- a. CERTIFICATE NUMBER
- b. REVISION NUMBER
- c. DOCKET NUMBER
- d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9215 16 71-9215 USA/9215/B(U) 3 OF 5
5.(b)(2)
Contents (Continued)
(ii)
For contents described in 5(b)(1)(i) contained within drum assembly shown as Item 4 on Neutron Products, Inc., Drawing No. 240122, Sheet 2 of 2, Rev. H:
(a) Maximum decay heat not to exceed 150 watts.
(b) Maximum activity not to exceed 9,500 curies provided all the following conditions are met:
At least 5 inches of full-diameter, axial shielding between the source and each shipping/transfer cask (S/TC) cover. Stainless steel, lead, or tungsten alloy may be used for 2 inches of shielding nearest the S/TC covers, with the remaining axial shielding provided by tungsten alloy.
The source is centered within the drawer cavity.
The source is of uniform activity.
(c) For configurations that do not meet all the conditions in 5(b)(2)(ii)(b), the contents shall be shown to meet the requirements in 10 CFR 71.47(b) in accordance with Procedure R-2014G.
(iii)
For contents described in 5(b)(1)(i) contained within drum assembly shown as Item 2 on Neutron Products, Inc., Drawing No. 240122, Sheet 2 of 2, Rev. H:
(a) Maximum decay heat not to exceed 100 watts.
(b) Maximum activity not to exceed 6,000 curies provided all the following conditions are met:
At least 5 inches of full-diameter, axial shielding between the source and each shipping/transfer cask (S/TC) cover. Stainless steel, lead, or tungsten alloy may be used for 2 inches of shielding nearest the S/TC covers, with the remaining axial shielding provided by tungsten alloy.
The source is centered within the drawer cavity.
The source is of uniform activity.
(c) For configurations that do not meet all the conditions in 5(b)(2)(iii)(b), the contents shall be shown to meet the requirements in 10 CFR 71.47(b) in accordance with Procedure R-2014G.
NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES
- 1.
- a. CERTIFICATE NUMBER
- b. REVISION NUMBER
- c. DOCKET NUMBER
- d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9215 16 71-9215 USA/9215/B(U) 4 OF 5
5.(b)(2)
Contents (Continued)
(iv)
For contents described in 5(b)(1)(ii):
(a) Maximum decay heat not to exceed 97 watts.
(b) Maximum activity not to exceed 20,600 curies provided all the following conditions are met:
At least 2 inches of full-diameter, axial shielding between the source and each shipping/transfer cask (S/TC) cover provided by lead or tungsten alloy.
The source is of uniform activity.
(c) Maximum activity not to exceed 4,000 curies provided all the following conditions are met:
At least 1 inch of full-diameter, axial shielding between the source and each shipping/transfer cask (S/TC) cover provided by lead or tungsten alloy.
The center of the source is not shifted axially more than 2 inches from the center of the drawer.
The source is of uniform activity.
(d) For configurations that do not meet all the conditions in 5(b)(2)(iv)(b) or 5(b)(2)(iv)(c), the contents shall be shown to meet the requirements in 10 CFR 71.47(b) in accordance with Procedure R-2014G.
- 6.
In addition to the requirements of Subpart G of 10 CFR Part 71:
(a)
The package must be maintained in accordance with Maintenance and Storage Procedure for USA/9215/B(U) Package, R-2019G.
(b)
The package shall be prepared for shipment and operated in accordance with Unloading and Loading Procedure for USA/9215/B(U) Package, R-2014G.
- 7.
The contents must be secured in the drum assembly by steel, lead, and/or tungsten alloy plugs and spacers so as to restrict movement in any direction to less than 0.25 inch. A minimum of 1-inch axial spacing between the source and each S/TC cover shall be maintained by steel, lead, and/or tungsten alloy plugs and/or spacers. Inert components integral to the source assembly/holder may also be used to maintain this spacing.
- 8.
The gross weight of the package must not exceed 6,000 pounds, and the inner shield cask shall be snug-fitting within the wooden overpack.
NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES
- 1.
- a. CERTIFICATE NUMBER
- b. REVISION NUMBER
- c. DOCKET NUMBER
- d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9215 16 71-9215 USA/9215/B(U) 5 OF 5
- 9.
Contents described in 5(b)(1)(i) and 5(b)(1)(ii) may not be shipped together in the same package.
- 10.
Fabrication of new packagings is not authorized.
- 11.
The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 71.17.
- 12.
Revision No. 15 of this certificate may be used until December 31, 2020.
- 13.
Expiration date: May 31, 2023.
REFERENCES Neutron Products, Incorporated, application dated May 7, 2018, supplemented by letter dated August 27, 2018, April 5, July 26, September 4, and November 11, 2019.
FOR THE U.S. NUCLEAR REGULATORY COMMISSION
/RA/
Daniel I. Doyle, Acting Chief Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Date: December 20, 2019