Notice of Violation from Insp on 810420-24
ML19352B010
Person / Time
Site: Prairie Island  
Issue date: 05/21/1981
From: Norelius C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML19352B008 List:
References
50-282-81-08, 50-282-81-8, 50-306-81-09, 50-306-81-9, NUDOCS 8106020550
Download: ML19352B010 (1)


Text

.

c.;

Appendix A NOTICE OF VIOLATION Northern States Power Company Docket No. 50-232 Docket No. 50-306 As a result of the inspection conducted.on April 20-24, 1981, and in accordance with the Interim Enforcement Policy, 45 FR 66754 (October 7, 1980), the following violation was identified:

Technical Specification 6.5 requires that written procedures for mainten-ance and tests be followed. Administrative Control Directive 5 ACD 3.14,

" Control of Measuring and Testing Equipment" requires in part that when calibrating instruments the as-found and as-lef t conditions be recorded.

Contrary to the above, test equipment which was calibrated by the site showed only as-left values or a notation of " Cal Check OK" on the cali-bration record cards. Additionally, some safety-related equipment that is calibrated under the preventative maintenance program had a single set of values which was labeled as " Actual" on the associated calibration record cards.

This is a Severity Level V violation (Supplement I).

Pursuant to the provisions of 10 CFR 2.201, you are required to submit to this office within twenty-five days of the date of this Notice a written statement or explanation in reply, including for each item of noncompliance:

(1) corrective action taken and the results achieved; (2) corrective action to be taken to avoid further noncompliance; and (3) the date when full com-pliance will be achieved. Under the authority of Section 182 of the Atomic Energy Act of 1954, as amended, this response shall be submitted under oath or affirmation.

N 7l 4"S kw Dated C. E. Norelius, Acting Director Division of Engineering and Technical Inspection 8106020650