ML19352A847

From kanterella
Jump to navigation Jump to search
Forwards IE Insp Rept 50-309/80-19 on 801201-26 & Notice of Violation
ML19352A847
Person / Time
Site: Maine Yankee
Issue date: 02/20/1981
From: Brunner E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Groce R
Maine Yankee
Shared Package
ML19352A844 List:
References
NUDOCS 8106020215
Download: ML19352A847 (2)


See also: IR 05000309/1980019

Text

'

'

.

,

O

  1. "#%,

UNITED STATES

9.-'l ) Q

M

NUCLEAR REGULATORY COMMISSION

O sg ,,.l j

REGION S

yg

asicanxavenue

og,,g,j

xino o, . ussia, een~svtvauia is o.

Docket No. 50-309

FEB 2 01981

Maine Ya_nkea Atomic Power Company

ATTN: Mr. Robert H. Groce

Senior Engineer - Licensing

1671 Worcester Road

Framingham, Massachusetts 01701

Gentlemen:

Subject:

Inspection No. 50-309/80-19

This refers to the routine safety inspection conducted by Messrs. W. Lazarus and

P. Swetland of this office on December 1-26, 1980, of activities authorized by

NRC License No. DPR-36 and to the discussions of our findings held by Mr. P.

Swetland with Mr. E. Wood of your staff at the conclusion of the inspection.

Areas examined during this inspection are described in the Office of Inspection

and Enforcement Inspection Report which is enclosed with this letter.

Within

these areas, the inspection consisted of selective examinations of procedures

and representative records, interviews iith personnel, and observations by the

inspector.

Based on the results of this inspection, it appears that one of your activities

was not conducted in full compliance with NRC requirements, as set forth in the

Notice of Violation, enclosed herewith as Appendix A.

This item of noncom-

pliance has been categorized into the levels described in the Federal Register

Notice (45 FR 66754) dated October 7,1980.

In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2, Title

10, Code of Federal Regulations, a copy of this letter and the enclosures will

be placed in the NRC's Public Document Room.

If this report contains any

information that you (or your contractor) believe to be proprietary, it is

necessary that you make a written application within 20 days to this office to

withhold such information from public disclosure. Any such application must be

accompanied by an affidavit executed by the owner of the informaticn, which

identifies the document or part sought to be withheld, and which contains a

statement of reasons which addresses with specificity the items which will be

considered by the Commission as listed in subparagraph (b) (4) of Section 2.790.

The informati'n sought to be withheld shall be incorporated as far as possible

into a separate part of the affidavit.

If we do not hear from you in this

regard within the specified period, the report will be placed in the Public

Document Room.

8106020 715

'

.

.

.

.

Phine Yankee Atomic Power Company

' 2

FEB 2 0 MMM

Should you have any questions concerning this inspection, we will be pleased

to discuss them with you.

Sincerely,

_+___

n-/

_

1

n

. Brunner, Chief

Re tor Operations and Nuclear

S pport Branch

Enclosures:

1.

Appendix A, Notice of Violation

2.

Office of Inspection and Enforcement Inspection

Report Number 50-309/80-19

cc w/ encl:

E. Wood, Plant Superintendent

E. W. Thurlow, President

.

I

9

't

-

-- , - - .

n--

- -- , , -. ~vn

s-,-,y-