ML19351F869

From kanterella
Jump to navigation Jump to search
Vol 2 Errata for Analysis of Hydrogen Control Measures at McGuire Nuclear Station
ML19351F869
Person / Time
Site: McGuire, Mcguire  
Issue date: 02/17/1981
From:
DUKE POWER CO.
To:
Shared Package
ML19351F865 List:
References
NUDOCS 8102200402
Download: ML19351F869 (4)


Text

.

DUKE POWER COMPANY

-AN ANALYSIS OF HYDR 0 GEN CONTROL MEASURES AT MCGUIRE NUCLEAR STATION Errata for Volume 2 1.

Section 2.3.3, Pages 2-18 The last word in line 2 should be " spray" instead of " steam."

2.

Chapter 4, Figure 4.2.3-1 A new F4 gure 4.2.3-1 (Rev. 1) is attached.

3.

Chapter 4, Figure 4.2.4-5 A new Figure 4.2.4-5 (Rev.1) is attached.

4.

Chapter 4, Figure 4.3.1-1 A new Figure 4.3.1-1 (Rev.1) is attached.

810 200 y09-

L

\\

~

I 1

O>

\\

\\

Il k

6

~[/

Q9M<y

\\

N A

\\

/

cyc4

"$1es 7q

/

\\ r

//

//

s N

\\s... y Xl A

D pf

\\^

d e

D,4

'g ds y 'j

\\ [W j'4 v M.

g

,..s ks l

. ' ".?,W

\\

~K

\\

\\

s f

'\\

l

. j'}gh

N/* 2 N,

s l

/

x N

A. 7 s

-W

(' /

\\

\\

a,.

\\

E.

\\

i$S.

/2 e

\\

R 7;e de*

\\

~

ds (a)

\\'

(b) i l

l 0 = P d6ds - (0,, ' dQ,)Rd; + Q Rde - 2l sin S E f-R ds

=

g

f d? is suf ficiently strail, then sin d^-p d{o l

pRdeds d'),'4d6 - N,<Nd",

0

=

c dQ l c,Y

= Il PR-g g

tjO pR R

4 T~tE*0

(

f. l RCU'T E R E tit I n' SIP.E':5 DERI'!AT I0fl Ficure 4.3.1-1 8

~(Rev. l' l

(

1

1, 30 -

70 -

60 -

-e G

50 --

c.

v e

La O

40 2_.

-c C

Le 1

30 20 -

10 1

1 i

i l

r 0

-4

-8

-12

-16

-20

-24 Radians x 10 '

~

Meridional Rotation

'4ade 109 Ficure 4.2.4-5

~(Rev. 1)

l A,

R(v) dz dr s) 2 (Z ' R ' ds 2' 2

2 ds 2

Layer 6 Layer 1 Layer 11 s

\\

P - Positive Pressure 4

1 dz (Z, R, g,, drg

,53)

Axis of symetry I

i Z(u) l i

l MARC TYPE 15, AXI-SYi'JiETRIC, CURVED Tiliti-SitELL ELEMEt;T Figure 4.2.3-1 (Rev. 1) 1

,,