ML19351F698

From kanterella
Jump to navigation Jump to search
Responds to Bulletin 74-01, Valve Deficiencies. Valves CV-530 & CV-531 Function as Block Valves in Pressurizer Pressure Relief Lines & Are Normally Open.Maint Performed by Visual Insp & Repacking During Each Refueling Outage
ML19351F698
Person / Time
Site: San Onofre 
Issue date: 01/30/1974
From: Coe R
SOUTHERN CALIFORNIA EDISON CO.
To: Engelken R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
IEB-74-01, IEB-74-1, NUDOCS 8102180350
Download: ML19351F698 (1)


Text

.

Southern Califomia Edison Company fE n o.som soo 2244 WALNUT GaOVc AVcNUc noncaru.coc noscwcao,cauroaNia sino M

j

,,u,,,,,

-. = = ~ - - -

. g \\h4

,a..,..,,,.

January 30, 1974 p

M C-pg,g 6 R. H. Engelken, Director M'

G.

Regulatory Operations, Region V W

D8 g; P. O. Box 1515 0?go$ s 4

Berkeley, CA 94704 c

g

Dear Mr. Engelken:

Docket No. 50-206 Valve Discrepancies We have reviewed all valves installed at San Onofre Nuclear Generating Station in accordance with the " Directorate of Regulatory Operations Bulletin No. 74-1. "

Our review indicates that two (2)

No. S-350 WDD, 2-inch double disc gate valves manufactured by the Darling Valve and Manu-facturing Company are installed at the San Onofre Unit 1 facility.

These valves, designated CV-530 and CV-531, function as block valves in the pressurizer pressure relief lines and are normally open. To date there have been no difficulties with either of these valves.

Routine maintenance of these valves, consisting of close visual inspection and repacking, is accomplished during each refuel-l ing outage. During the 1973 refueling, both valves were completely disassembled, inspected and the internals showed no abnormal wear or indications of distress. All seating surfaces were polished and new bonnet gaskets installed. The valves were repacked, stroked and the position indication adjusted. No further maintenance was necessary and both valves continue to function satisfactorily.

We have no valves manufactured by the Walworth Company similar to those described in your Bulletin 74-1.