Text
.
APPENDIX A NOTICE OF VIOLATION Union Carbide Corporation Docket No.70-687 Based on the results of an NRC inspection conducted on September 17-19, 1980, it appears that one of your activities was not conducted in full compliance with the conditions of your license as indicated below.
Item A is an infraction.
A.
Item 14 of Amendment 1 to Special Nuclear Material License No. SNM-639 states, "...the licensee shall post all storage and use locations with criticality safety signs which indicate the maximum quantity of special nuclear material that is authorized at each location and the actual amount that is present at each location."
Contrary to the above, on September 17, 1980, a fuel storage cabinet in the Plating Area on the second floor of the Hot Lab Building was not posted with a criticality safety sign indicating the actual amount of special nuclear material present.
According to a licensee representative, approximately 325 grams of Uranium-235 were in the fuel storage cabinet.