Confirms Receipt of Re Work Hold Agreement 13, Issued 801120 to Daniel Intl.Corrective Actions to Be Taken Prior to Agreement Release Include Shifting Responsibility for Pipe Cleanliness to Installing Const Craft
ML19351E799
Person / Time
Site: Wolf Creek 
Issue date: 11/26/1980
From: Seyfrit K
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Koester G
KANSAS GAS & ELECTRIC CO.
References
NUDOCS 8012190318
Download: ML19351E799 (2)


Text

.

"[ N, UNITED STATES NUCLEAR REGULATORY COMMISSION REGION IV

.g g

611 RYAN PLAZA DRIVE. SUlfd 1000 ARLINGTON, TEXAS 76011 November 26, 1980 In Reply Refer To:

RIV Docket No. STN 50-482 Kansas Gas and Electric Company ATTN: Mr. Glenn L. Koester Vice President - Nuclear Post Office Box 208 Wichita, Kansas 67201 Gentlemen:

This confirms our receipt of your letter to Mr. W. C. Seidle, dated November 25, 1980, concerning Work Hold Agreement No. 13, issued November 20, 1980.

The Work Hold Agreement, applicable to final fitup, welding and bolting of safety-related piping, was issued to Daniel International for corrective action to be taken relative to pipe cleanliness conditions at the Wolf Creek Generating Station.

Reactor coolant piping and small bore pipe fabrication under other cleanliness controls are excluded from the Work Hold Agreement.

Specifically, with regard to corrective actions that are to be taken prior to release of the Work Hold Agreement, we understand that:

1.

Responsibility for maintaining pipe cleanliness after the pipe leaves the staging area and is brought into the building will be shifted to the con-struction craft responsible for installation of the pipe as follows:

a.

The craft foreman will be responsible for assuring pipe cleanliness until just prior to fitup and for verifying cleanliness prior to.

requesting cleanliness inspection. The foreman will also be responsible for assuring that da.ns and seals are in place during weld preparation and other similar activities.

b.

An independent group of craft personnel will monitor in-process cleanliness.

c.

Qualicy control will inspect the pipe for cleanliness, just p'rior 'to fitup after the pipe his been placed in position for instalgation.

'cl

(

p 4 $.

o.

e f

l

,e

.N.

CO*

a u

i CERTIFIED MAIL 5

us - 5

?

. RETURN RECEIPT REQUESTED fj

cj ga

\\

1 i0121 M h %

Kansas Gas and Electric Company November 26, 1980 d.

After the pipe is erected and installed, quality control will verify cleanliness and seal all open ends of the pipe.

e.

If it is necessary to delay fitup and reinstall caps after the pipe is released for fitup, quality control will apply seals to the caps.

Quality control will witness removal or replacement of sealed caps.

f.

If additional work on the pipe is necessary prior to fitup, control of the pipe will be returned to the craft by voiding of the release for fitup by quality control. Quality control will again inspect and release the pipe prior to fitup.

1 2.

All craft, engineering and quality control personnel involved with instal-lation of piping will be retrained in the requirements of the new pipe cleanliness program prior to resumption of work.

3.

"Hard Card" portable listings of cleanliness requirements will be issued to craft, quality control and engineering personnel. The cards will be revised to list key information and will be of sufficient size to assure legibility.

4.

All appropriate work and quality control procedures will be revised to implement the above program and will be issued prior to resumption of work.

We request that you inform this office sufficiently in advance of any plans that-you have to resume work so that we may evaluate your pipe cleanliness program prior to release of the Work Hold Agreement.

If your understanding of this matter is inconsistent with the above, please contact this office immediately.

Sincerely

,f K. V. Seyfrit Director e