Forwards LER 80-053/03L-0
Date released: 12/31/2019 Download: ML19351E633


LER 80-053/03L-0:on 801101 & 07,containment Atmosphere Particulate Monitor Failed.Caused by Loosened Channel Field Cable Leads Due to Improper Crimping.New Connectors Properly Installed
ML19351E638
Person / Time
Site: Calvert Cliffs 
Issue date: 12/01/1980
From: Lagiewski J, Rizzo P
BALTIMORE GAS & ELECTRIC CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19351E638 (2)
Forwards LER 80-053/03L-0
ML19351E632
Person / Time
Site: Calvert Cliffs 
Issue date: 12/01/1980
From: Russell L
BALTIMORE GAS & ELECTRIC CO.
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19351E632 (1)