ML19351E583

From kanterella
Jump to navigation Jump to search
Forwards LER 80-029/03L-0
Date released: 12/31/2019 Download: ML19351E583


LER 80-029/03L-0:on 801106,outboard Motor Bearing on Containment Spray Pump SI-3C Motor Found Severely Degraded & Motor Shaft Scored.Probably Caused by Lack of Oil to Bearing.Bearing Replaced & Rotor Shaft Repaired
ML19351E585
Person / Time
Site: Fort Calhoun 
Issue date: 11/07/1980
From: Mueller R
OMAHA PUBLIC POWER DISTRICT
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19351E585 (4)
Forwards LER 80-029/03L-0
ML19351E582
Person / Time
Site: Fort Calhoun 
Issue date: 11/21/1980
From: Stevens S
OMAHA PUBLIC POWER DISTRICT
To: SEYFRIT K V
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19351E582 (1)