ML19351D969

From kanterella
Jump to navigation Jump to search
IE Insp Rept 70-1113/80-17 on 800908-11.Noncompliance Noted:Failure to Include Matl Discarded as Liquid Effluents During Matl Balance Period in Limit of Error Calculation. Details Withheld (Ref 10CFR2.790)
ML19351D969
Person / Time
Site: 07001113
Issue date: 09/26/1980
From: David Jones, Kahle J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML19351D965 List:
References
70-1113-80-17, NUDOCS 8011200489
Download: ML19351D969 (1)


Text

"

ETER*alTRANSMiTTED HEREWml em / o us,#'o CONTAINS 2.E INFORMATION o

U UNITED STATES k

8 7,

NUCLEAR REGULATORY COMMISSION

)

REGION il e I o

101 MARIETTA ST N.W.. SUITE 3100 ATLANTA. GEORGIA 3o3o3 SEP 26 wuc Report No. 70-1113/80-17 Docket No. 70-1113 License No. SNM-1097 Safeguards Group III Licensee: General Electric Company P. O. Box 780 Wilmington, NC 28401 Facility Name: Wilmington Manufacturing Department Inspection Conducted: September 8-11, 1980 Type of Inspection: Unannounced Material Control & Accounting Inspector:

N 6Ilt

~

'l 4//?

n D. W/ Jones, Statistician

/Date Signed Approved by: 9)LI[tllt M24/fD J.J. Kahle, Acting Chief, MC&A Section Date Signed Safeguards Branch Inspection Summary Areas Inspected: Inventory Difference and Associated Limit of Error, and Inde-pendent Measurement Verification.

The inspection involved 25 inspector-hours on site by one NRC inspector and was begun during the regular hours.

Results: The licensee was found to be in compliance with NRC requirements in the two areas examined during the inspection except for the following item:

(Deficicacy) Failure to include in the limit of error calculation all of the material discarded as liquid effluents during the material balance periad (80-17-01).

5-72 MO - // i - _

Copy of Copies 83 Pages This Document is not to be reproduced without specific approval of IE:II g0112 P " LI$

i ETERIALTRAKSMTTED HEREWml sumeKo wa wanunem