ML19351D737
| ML19351D737 | |
| Person / Time | |
|---|---|
| Site: | Yankee Rowe |
| Issue date: | 11/02/1978 |
| From: | Ziemann D Office of Nuclear Reactor Regulation |
| To: | Groce R YANKEE ATOMIC ELECTRIC CO. |
| References | |
| NUDOCS 8011170749 | |
| Download: ML19351D737 (4) | |
Text
_
g: g.=
.. 7-DISTRIBUTION N
A ket Files 50-29 HS it,
NOVEMBER 0 t 1978 NRC PDR f
no Local PDR
":==
Docket flo. 50-29 ORB #2 Reading
- i.?===-
SEPB Reading b
Yasikee Atonic Electric Company DLZiemann "ll.
ATTI::
!'r. Robert H. Groce DKDavis Licensing Engineer HLEvin FT 20 Turnpike Road TCheng 3..
. =
l!estboro, itassachusetts 01581 TCardone ABurger Gentienen:
VStello (i:..g DGEisenhut
'=
As recently discussed with you in connection with the NRC Systematic
- =
Evaluation Program, the following staff cembers will visit the Yankee
=
Rowe facility on ?!ovember 8 and 9,1978.
Pr _
11RC Social Date of lN tiate Badae No.
Security flo.
Birth
- TA
....=.:
Howard A. Levin Bill 7 158-44-7598 6/27/52 S
C Thomas fl. Cheng 84197 058-40-7655 6/11/35 Thomas Cardone _
B1413 022-22-3021 5/08/30 p.
Edward Franklin Hawkins C2179 443-34-1030 11/10/37
[_.
i The purpose of the visit is to observe site geology, hydrology and
[:
centechnical features at Yankee Rowe and to obtain infomation not available to the staff on the Yankee Rowe docket.
ThE proposed agenda for the site neeting is provided in the Enclosure.
p Sincerely,
[
e Osams: 4ca ey
/
h Dennis L. Zie, ann, Chief 7/
Coerating Reactors Branch #2 Division of Operating Reactors h:-
l
Enclosure:
E As' stated ccw/c[1 closure:
.g..
See next page a
a
" 8 #2iC 00R:SEEB/S&R DOR:. ORB J2...
o
'c. -
HLevin:rjk ABurger h.D Ziann- -.
.u.~.--
. }l..-i -12 2l iL -is13 1L k R i i acum
, ~ ~ -...- -
ac - m o.go111 '2 0 7tf 9 g
.y
.z
~
= = = = +
- .2
=
=::
. ::=
b Yankee Atomic Electric Company 2-p=
1
- =
5sN
- =g=
cc w/ enclosure:-
- =
Mr. Lawrence E. Minnick, President W2
. Yar.kee Atemic Electric Company _
...=55 20 Turnpike Road.
L...;-
- Westboro, Massachusetts. 01581
-4~
= = -
1
. Greenfield Comunity College-
- =i il Colleg Drive Greenfield, Massachusetts 03101
=
="
.==y,._
udi~-
. s...
J e.-
- * ^..
Ei::.= -
k=E=i
{.
y_ ~ =
y;=-
[......
j i-
,1 =;.,..
J
..-..y i
b
[i t
.iij
=3 w
gy ve TTma-k---'+
e-4 e T
eT*
+N"+
N T
~#1 V--
=-'-+f F-wr' c
Fbe-=>+1s
-tm r*&-ev4*
m. e aew a.I
.q.g ierp..
r m= =.
AGENDA
=
SITE VISIT - YANKEE R0WE
((
GEOLOGY, GECTECHii!CA!., SEIStiIC h:I:=E
~
Em+L
...g. rr.
NOVEMBER 8,'1978
.. = :
8:30 a.m.
Meet at site
~l.} _
8:45 a.m.
Securi ty.
9=
9:00 a.m.
Brief-discussion to outline scope of review and site tour
=
10:00 a.m.
Tour of sit'e Pg 12:30 p.m.. Lunch-w-
~
s 1:30 p.m.
Tour of Sheman Dam 8
..-a 2:30 p.m.
Meeting to discuss observations, identify the need for additional infomation
[.'.u..
4:00 p.m.
Adjourn H0VEMBER 9, 1978 9:00 a.m.
Meet at Harriman Dam 9:15 a.m.
Tour. Harriman Dam 10:30 a.m. ~ Meeting to discuss observations, identify the need for r..
l additional infonnation
~
12:00 p.m..
Adjourn
- i..
N:
ITEMS TO BE REVIEWED L'
The.t:RC would like to discuss the following:
==
'1.
Dam Integrity - ~StabilityLduring seismic event
][
a.
geology in area of the dam b.
details of construction, including a description of materials of construction, and insitu foundation materials c.
any stability. analyses coupleted 1
iw= T
~
. =
-2_
2.
Hydr 01ogy
==
.:ii&5h a.
site drainage facilities
- =J b.
design basis flood. levels J55
._ zg=
c.
flood protection facilities 7_1 ~
d.
river and reservoir profiles and cross sections
~
-=
e.
upstream and downstream dam hydraulic features - spill'.ay 7"
details, rating curves, tailwater rating curves, outlet works
=
f.
UHS water supply. normal shutdown, emergency conditions, ii={
alternate supplies g.
technical specifications and emergency operating procedures hh j::: T:
.._.4 3.
Slope Stability - Natural and Engineered
~
- =:
4.
Settlement of Foundations and Buried Equipment
==
a.
observations of settlement markers b.
construction records c.
foundation drawings 5.
Geology & Topography a.
faulting investigations b.
mappi ngs c.
lineament studies
- d. -boring logs j
e.
logs of cuts
.H b
.l-
- 6.. Soil Prcperties q
a.
dynamic and static b.
seismic refraction studies c.
water tables.
.-1 o
++
=