Text
.
"00R oggg q e
OPERATLv'; DATA REPORT DOCKET NO. 50-333 DATE OCTORFR 1980 COMPLETED IIY p r_
vitrELT TELEPHONE, 111 14
1840 OPERATING STATUS Fit:: Patrick Notes
- 1. Unit Name:
- 2. Reporting Period:
Annan1_annotn
- 3. Licensed Thermal Power (MWt):
4 th
- 4. Nameplate Rating (Gross MWe):
883
- 5. Design Electrical Rating (Net MWe):
821
~ 6. Maximum Deper dable Capacity (Gross MWe):830 800
- 7. Maximum Dependable Capeity (Net MWe):
- 8. If Chan;es Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report.Give Reasonsi NONE
- 9. Power Level To Which Restricted,if Any (Net MWe):
NONE
- 10. Reasons For Restrictions.If Any:
This Month Yr.-t o-Da t e Cumulatis e I1. Hours in Reporting Period 720 6575 45408
- 12. Number Of Hours Reactor Was Critical 71u 4155.1 307R5.3
- 13. Reactor Reserve Shutdown liours 0
0 0
- 14. Hours Generator On Line 720 4048 29786
- 15. Unit Reserve Shutdown Hours 0
0 0
- 16. Gross Thermal Energy Generated (MWH) 1645872 8040096 59228290
- 17. Gross Electrical Energy Generated (MWil) 558030 2748520 20102220
- 13. Net Electrical Energy Generated (MWH) 542145 2660295 19450870
- 19. Unit Senice Factor 100's 61.6%
65.6%
- 20. Unit Availability Factor 100%
61.6%
65.6%
- 21. Unit Capacity Fa. tor (U3ing MDC Net) 94.1%
90 6%
99 ;%
- 22. Unit Capacity Factor IU3ing DER Neo 91.7%
49.3's 52.2'6
- 23. Unit Forced Outage Rate 0
3.9%
19.1%
- 24. Shutdowns Scheduled Oser Ne.st 6 Months (T pe. Date.and Duration of Each):
3 Scheduled snubber inspection and maintenance outage in January. 1981.
for approximately-10 days.
- 25. If Shut Down At End Of Report Period Estimated Date of Startup:
- 26. Unii> In Test Status (Prior to Commercial Operation):
Forecast Achieses' INITIA L CRITICALITY INITIA1. ELECTRICITY CO\\lilERCIA L OPERATION i
8010100 $ /
l t
AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.
gn_ttt UNIT JAFNPP DATE OCTOBER 1980 E. ZUFELT C0\\lPLETED BY 4
TELEPHONE 315-342-3840 4
SEPTEMBER 1980 MONTH DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)
(MWe Net) 796 532 37 582 99 2
18 3
648 19 797 798 4
695 20 5
5i' 21 709 6
670 22 797 763 798 7
23 8
766 24 800 9
767 25 803 10 763-26 ena 1I 768 27 809 12 770 28 809 13
'66 29 R11 14 770 30 808 772 IS 3,
16
?R3
SUMMARY
- UNIT OPERATING AT NEAR FULL THERMAL POWER FOR THIS REPORTING PERIOD.
D '"
- D
]D~T sJL 2..j Q i
w oJ Inlo O
.o to u
i-g a
w n
C L
- a. v E
Z
=
i o
- ts e.
c:
2 -s c g.3 u
F f
L; m
s.,
V
=>
V o
5~c" F
2 C :.:
I w
-a u
e e a g
se
~"-M y
=t u
M C
< O,
r WF
=
u c,
O2,34 2
in 9 0
=
c = -*
=
W dE 1
gWW>mZ 25,2 ~
Z<H2<c
-3 5 0
0 M ".g, u
o
= u 4
H Zo w O.2 $
.= S Di %
u
.=
$H HI 4~-
O
.= g b E ~
e W
u<
=
w z a4
===ue x
o a sg a
C wcwwo u
2 o
g o
o u
y a
v m
O k
b O2 O
L (nz C
.=
c 3 -
0 m
f S3P03 5M?!
g sueuodwo3 g
c.o &
~
c m ;w 1
w
..~*K=~
u 5
???50-a g
a
. =,.,==
w y
,,8P"3
~22<0 3:
tuaisAs s
2-M4 o
E Z
a.
m z
Z 4
o.
o mZ d
osE:
3:
H cu :
s o
.3 0 &
z E
o a
M
=
m aw a.-.
x
==
m
-a b
.JOI. stag timog j
Z Suiiings
?
,e 3_
30 PUNIEW h 3a
..s a
g U
b "g 5.h
.t!OS FJM C
U =a
-=F
- =m.
+-
-0
,Q u =
"d ?,-=
w N 5.5 _" _"E y
DS
($J nO[{ }
Ed m,,.2 3.I.,
e on (80'icin0 E55i3E5-ue 232520
= = = C JO 'J C M.
,5 *** ~5 g
- J C. *")
$u2z%O<OC5. d "';"
[3d A.
l
'#3 4 s *0 d.l:
ri D
LO 5
O C
C m
l u
l C
3 "=-
1 M
u7
.J. u
.- c.n 4
N3 i
f M
.A M l
i i
l 1
1 1
POWER ALTrICRITY CF THE STA'IE CF NEW YCRK 4
JNES A. FITZPATRICK NUCIZAR PCh"G PLMTT NARRATIVE SLWEY CF CPERATING EXPERIEICE SF2TEGER,1980 Tne unit operated at near full the:ral power during this reportirg period.
Power was reduced on Septe:ter 5,1980, for control rod pattern change and valve testing.
At the end of the reporting period the unit is operating at approxinately 835 We.
l i
POWER AUTHORITY OF THE STATE OF NEW ' YORK JAMES A. FITZPATRICK NUCLEAR POWER PLANT MAINTENANCE SUVMARY
. SEPTEMBER 1980 I f C i
T WORK REQUEST #
CAUSE OF RESULTS OF E U TIME OATE SYSTEM HOW DETECTED COMPONENT #
MALFUNCTION MALFUNCTION RECURRENCE HOURS 8185 "A" Pen Failed Adjusted Mechani-
[9/8/80 02 TR-165 Ops Unknown Upscale cally Calibrated 6.0 4956 9/15/80 02-3
.let Pump IE I f,C N/A M/A Calibrations 110.0 8286 Cannot Obtain Rod
- 9/15/80 03 CRI) 02-35 Ops Unknown
((idrawelPermis-Replace Relay 8.0
.l No "4" Digit At 8310
.I9/24/80 03 CRD 18-11 Ops Bad IC Chip P sition "48" Repaired 2.0 6273 RSCS Does Not See 9/24/80 03 CRI) 26-07 Ops Bad IC Chip Full Out Renniro,1 an 6265 ItSCS Does Not See h/24,80 03 CRD 14-27 Ops Unknown Full Out Found or i n 6266 itSCS Does Not See 1/24/80 03 CRD 30-27 Ops Unknown Pul1 Out
- ound OK I.0 8197
)/18/80 06 I'l -90 A. B.C Ons
.Onn fliph Rr n<linoe
n l i lu 2 + n,i 10.0
POWER AUTHORITY OF THE STATE OF NEW YORK JAMES A. FITZPATRICK NUCLEAR POWER PLANT MAINTENANCE
SUMMARY
SEPTliMBER 1980 I f, C WORK REQUEST #
CAUSE OF RESULTS OF ACTION TAKEN REPAIR DATE SYSTEM HOW DETECTED UbMPONENT #
MALFUNCTION MALFUNCTION TO PRECLUDE TIME RECURRENCE HOURS Ran I-V Curve 7500 Incorrect Performed 9/2/80 07 LPRM 36-05C Ops Use Indication IMP 7.22 1.0 Ran I-V Curve 7573 Incorrect 3#$_$_U 9/2/80 U/
LPIGl 36-21B Ops Use Indication 1.0 7721 LPRM Spiking f.3","f. [_ f 9/2/80 07 LPIG1 20-21C Ops CRD Changcout Upscale 9.5 Cleaned, Dried 7730 LPRM Failed 9/2/8b 07 LPRM 20-29D Ops CRD Changeout Upscale f.3","f.k_f_
9.5 Ran I-V Curve 8008 Incorrect
(((f.$_f_
9/2/80 07 LPIG1 44-37B Ops IJsc Indication 1.0 Cleaned, Dried 7914 LPRM Failed 9/2/80 07 LPIG1 04-29B Ops CRD Changcout Upscale
$ "," k f 9.5 8257 IIUP"II"U lleturned to Servict 0.5 J/24/80 07 LPlol 44-2'll Ops Unknown Drifting 8333 Drifting tepaired 1/24/80 07 LPRM 28-45A Ops Unknown Upscale
- leturned to Service 1.0 8022 tan I-V Curve 1/24/80 07 LPRM 44-29B Ops Unknown Drifting 1.0 8189 lan I-V Curve 1/24/80 07 ih41 04 -29B Ops Unknown Drifting
["# f, f.$$
d 1.0 m
- ^ - " - " - - - - - ^ ^ ~ ~
POWER AUTHORITY OF THE STATE OF NEW YORK JAMES A. FITZPATRICK NUCLEAR POWER PLANT MAINTENANCE
SUMMARY
SEPTEMBliR 1980 1 r, C Tl WORK RE00EST #
CAUSE OF RESULTS OF DATE SYSTEM FiOW DETECTED COMPONENT #
MALFUNCTICN MALFUNCTION E
TIME RECURRENCE HOURS 834 Indication Adjusted Gain /
9/2/80 10 1.S-105B Ops Age Incorrect Sensitivity 4.0 7431 Wires Broken Constant Replaced Sensor 9/11/80 10 LS-104 Ops By Workers Alarm
- 1. cad s 24.0 8001 Check Performed F-ISP 9/8/80 11 L1-66 4 46 Ops N/A Indication Found Satisfactory 15.0 8307 Faulty Circuit Incorrect Replaced IC 9/26/80 17 RTs!T31 G 432 Ops Board Isolation and Calibrated 16.0 5316 Perform BOP 9/2/80 93 W
IGC N/A N/A a1ibrations 200.0
POWER AUTHORITY OF THE STATE OF NEW YORK JAMES A. FITZPATRICK NUCLEAR POWER PLANT SAFETY RELATED ELECTRICAL 8 MECliANICAL MAINTENANCE
SUMMARY
DATE SYSTEM WORK REQUESTf REPAIR HOW DETECTED CAllSE OF MALFUNCTION ACTION TAKEN TO PRECLUDE RECURRENCE TIME ENT#
HOURS 5/17 00 6656 N/A None l'erform In-Service Inspection of lleactor 189 Various Vessel Internals 8/25 03 7546 OPS Accumulator Sea ts i.eaking iteplace liydraulic Control (Jnit Accumu-16 IICH 14-43 lator o
H/14 01-125 74S6 OPS Clogged Drain 1.ine Cut Line, Blew Out, Pumped Out Water 16 SilGT 1.Inc to Stack 8/28 17 7585 OPS Cruil in Sample 1.ine Disassembled T Cleaned I.ines f. Flow 6
Service Water Gauge Blonit or Flow Switch 4
8/21 10 5921 Visual NitC llullet in 79-02 Floili fied lilo-48A 20 ll10 -48 A Inspection 8/18 15 5939 Visual NitC llullet in 79-02 flod i fi ed 1115-323 10's ill5 32X Inspection 8/19 10 5931 Visual NitC Hullet in 79-02 Flod i fi ed 1110-72 50 ll10-72 Inspection t
8/21 66 59/9 illTK 37811 Visual NitC llulletin 79-02 Modified IIFSK 378tl 54 Inspection 8/21 ao 5930 Visual NI!C llulletin 79-02 Modified IlFSK 332 5
Ill SK 332 luspection 8/21 66 5932 Visual NitC llulletin 79-02 flodi fied ilFSK 337 72 ilFSK 337 Inspection
POWER AUTHORITY OF Tile STATE OF NEW YORK
~
JAMES A. FITZPATRICK NUCLEAR POWER PLANT SAFETY RELATED ELECTRICAL 8 MECilANICAL MAINTENANCE
SUMMARY
RE S
DATE SYSTEM fl0W DETECTED CAUSE OF MALFUNCTION ACTION TAKEN TO PRECLUDE RECURRENCE T ME 1100RS 8/21 10 5934 Visual NitC llullet in 79-02 Ik>tli fi ed 1110-113 12115
~1110-113 Inspection 8/26 10 5214 Visual NitC llul let in 79-02 tiott i fi ed 1110-506 8 713 1110-506 Inspection 8/26 15 5239 Visual NitC llulletin 79-02 Flodi fied PI:SK 810 219's Pl:SK 810 Inspection 8/26 15 5898 Visual NitC flulletin 79-02 tiodi fied ll15-135 72!3 1115-135 Inspection 8/26 66 5899 Visual NitC 11ul let in 79-02 Flodi fied ill:SK 487 131 3/4 Ill:SK 487 Inspect. ion 8/26 66 5895 Visual NitC llulletin 79-02 Flotti fied Ill:SK 469 217 Ill'SK 469 Inspection 8/26 66 5901 Visual NilC Ilullet in 79-02 Ikitti ficil 1166-4 256 1166-4 Inspection 8/26 66 5914 Visual NitC llullet,in 79-02 Flodified IllSK 338 196'4 lil:SK 338 Inspection 8/26 23 5920 ii23-61 Visual NitC Ilutletin 79-02 Flod i fi ed 1123-61 276's inspection 8/26 12 5924 Visual NilC 11ullet in 79-02 Flodi fied PI:SK 1016 252!3 PfSK 1016
- nspection 8/26 12 5925 Visual NitC Ilut let in 79-02 Flodi fied PI:SK 1036 217'3 PI:SK 1036 Inspection
POWER AUTilORITY OF Tile STATE OF NEW YORK JAMES A. FITZPATRICK NUCLEAR POWER PLANT SAFETY RELATED ELECTRICAL a MECilANICAL MAINTENANCE
SUMMARY
WORK REQUEST #
REPAIR DATE SYSTEM liOW DETECTED CAUSE OF MALFUNCTION ACTION TAKEN TO PRECLUDE RECURPENCE TIME f
ilOURS 8/26 27 5928 Visual NItC llulletin 79-02 Flodified AZ-27-54 105'.
AZ-27-54 Insic'ct ion 8/26 19 5933 Visual NitC llulletin 79-02 Flodi fied ll19-231 34 ll19-231 Inspection r
8/27 100 5943 Visual NitC Bulletin 79-02 Ploili fied llanger D 42 Ilanger Ti-Inspection 8/27 67 5230 Visual NitC thallet in 79-02 Ptodi fied 1167-1 308 116 7 - 1 Inspection 8/28 15 5894
. Visual NitC Bullet in 79-02 flod i fi ed 1115-108 176's ifl5708 inspection 8/28 10 5949 Visual NitC Butletin 79-02 Flodi fied 1110-50B 13 ll10-5011 Inspection 8/28 10 5906 Visual
.NitC Bulletin 79-02 flodi fied PI:SK C 173 3/4 lil:SK C Inspect ion 9/4 01-125 I:N I Arill Visual 1.oose Isel t s/ worn l>el t s Atij us t ed l>ci t s/ replaced fiel t s 7
8168 9/4 66 7598 OPS l' ump rinining hot 1.ul>rica t eil l>e.irings 3
(ilTI3B 9/4 14 5160 Visual NitC Bulletin 79-14 llemoveti Illi 1 65'3 Illi I inspection 9/12 93 8279 Ol'S f-li sailj ust ment of relay Adj :5ted ami cleaned contacts 4
I!GP-A contacts in panel alarm horn
POWER AUTHORITY OF Tile STATE OF NEW YORK JAMES A. FITZPATRICK NUCLEAR POWER PLANT SAFETY RELATED ELECTRICAL a MECHANICAL MAINTENANCE S'JMMARY WORK REQUEST #
DATE SYSTEM fl0W DEiECTED CAUSE OF MALFUNCTION ACTION TAKEN TO PRECI UDE RECURRENCE TIME COMPONENT #
HOURS 9/12 27 8195 Ol'S llroken position switch ite-welded sheareil posit ion swit ch 3
PNS-126A Actuating arm valve actuating tab 9/10 17 8264 Ol'S Noisy Flotor/ blower Assembly lleplaced roots blower 4
illi-436 A r
9/17 11
,6536 Fl.i i n t 1.oose elect rica l connect ion Iteplaced connector, t ight ened, anil 6
11-150 at switchgear.
retaped.
9/5 67 5900 Visual NitC llulletin 79-02 Flodi fied AZ 16f.20 169 3/l AZ-67-16T.20_
Inspection 9/5 10 5918 Visual NitC llutletin 79-02 Flodi fied ll10-217 600's 1110-217 Inspection 9/5 10 5912 Visual NRC Ilullet in 79-02 Flodi fied ll10-512 104 ll10-512 Inspect ion 9/8 15 5916 Visual NRC llulletin 79-02 Mod i fied De t a i l A 404'4 Detall A Inspection 9/8 10 5935 Visual NRC Hulletin 79-02 Mod i fied 1110-172 128'3 i110-172 Inspection 9/8 46 5916 Visual NitC llullet in 79-02 flotli fied I'I SK 1350 36 PiSK 1350 Inspection 9/9 23 5917 Visua1 NRC Ilullet its 79-02 ModiIied l123-95 139 il23-75 Inspection 9/11 10 5177 Visual NRC llulletin 79-02 blod i fied 1110-522 250 ll10-522 Inspection
POWER AUTHORITY OF THE STATE OF NEW YORK JAMES A. FITZPATRICK NUCLEAR POWER PLANT 1
SAFETY RELATED ELECTRICAL a MECHANICAL MAINTENANCE
SUMMARY
6 DATE SYSTEM HOW DETECTED CAUSE OF MALFUNCTION ACTION TAKEN TO PflECLUDE REClflRENCE 9/11 15 5887 Visual NitC Ilullet in 79-02 Flodi fied ll15-165 229 l115 - 165 Inspection 9/11 15 5938 Visual NitC Ilullet
-02 Flod i ficti l'l:SK 1090 21 PISK 1090 Inspection, 9/11 15 5940 Visual NltC llulletin 79-02 Flotli fied 1115-325 5
1115-325 Inspection 9/11 10 5918 Visual NitC linitetin 79-02 Flodi fied ll10-516 34 1110-516 Inspection 9/15 14 5,188 Visual NI!C llul lt -
9-02 Flodi fied ll11-50 107 3/4 1114-50 Inspection 9/15 10 5941 Visual NitC lini tet in 79-02 Flodi fied l110-482 57'3 ll10-482 Inspection l