Notification of 801014-17 Meeting W/Util at Site to Discuss Seismic Qualification Review Team Audit
ML19351D048
Person / Time
Site: Summer 
Issue date: 09/15/1980
From: Kane W
Office of Nuclear Reactor Regulation
To: Schwencer A
Office of Nuclear Reactor Regulation
References
NUDOCS 8010080642
Download: ML19351D048 (5)


Text

NU a

k3 RfC

(

'o UNITED STATES g

8 NUCLEAR REGULATORY COMMISSION n

h WASHINGTON, D. C. 20555

\\

/

SEP 151990 Docket No. 50-395 MEMORANDUM FOR:

A. Schwencer, Chief Licensing Branch No. 2, DOL FROM:

W. Kane, Project Manager Licensing Branch No. 2, D0L

SUBJECT:

FORTHCOMING MEETING WITH SOUTH CAROLINA ELECTRIC AND GAS COMPANY

/4 -/ 7 DATE & TIME:

October 640',1980 9:00 a.m.

LOCATION:

Virgil C. Summer, Nuclear Station, Unit 1 Jenkensville, South Carolina PURPOSE:

Seismic Qualification Review (SQRT) Team audit. See attached list of equipment to be audited.

PARTICIPANTS:

SCE&G Company R. Clary et. al.

NRC Staff A. Lee, J. Skolds et. al.

//

cv -

William Kan, Project Manager Licensing Branch No. 2 Division of Licensing cc:

See next page S010080 $ N

Ak, s EQUIPMENT LIST FOR SQRT PLANT SITE REVIEW I.

B0P Mechanical Equipment 1.

Reactor Building Cooling Unit (AH, XAA-1 A,B), Assembly 2.

Reactor Building Cooling Unit (AH, XAA-1 A,B), Damper activator 3.

Component Cooling Water Pump (CC,XPP-1A, B.C) Pump and motor 4.

Turbine Driven Emergency Feedwater Pump (EF, XPP-8), Pump and Turbine piping appurtenances l

5.

Main Feedwater Isolation Valves (FW,XVG-1611 A), Valve and actuator l

6.

Control Valve (MS.IF-2030) 7.

Main Steam Isolation Valve (MS,XVM-2901A) j 8.

Main Steam Safety Valve (MS,XVS-2806A) i 9.

Refueling Water Storage Tank (SF, XTK-25)

II.

NSSS Mechanical Equipment 1.

Charging Pump (CS,XPP-43A) 2.

Residual Heat Removal Pump (RH,XPP-31) l III. B0P Category I Instruments, Electrical Equipment and Supports 1.

480 Volt Unit Substations 2.

Battery Chargers i

3.

Transfer Switches (7200 Volt) 4.

Control Board Switch Modeles l

S.

Reactor Protection Under-frequency and Voltager Relay Panels 6.

Main Control Board 7.

Hydrogen Analyzer Panels IV. NSSS Category I Instrument, Electrical Equipment and Supports 1.

Pressure Transmitters and Differential-Pressure Transmitters 2.

Post Accident Monitoring Equipment (Indicators).

l

(k_ _o Mr. T. C. Nichols, Jr.

Vice President & Group Executive Nuclear Operations South Carolina Electric & Gas Company P. O. Box 764 Columbia, South Carolina 29281 cc: Mr. William A. Williams, Jr.

Vice President South Carolina Public Service Authority 223 North Live Oak Drive Moncks Corner, South Carolina 29461 Troy B. Conner, Jr., Esq.

Conner, Moore & Corber 1747 Pennsylvania Avenue, N. W.

Washington, D. C.

20006 Mr. Mark B. Whitaker, Jr.

Group Manager - Nuclear Engineering & Licensing South Carolina Electric & Gas Company P. O. Box 764 Columbia, South Carolina 29218 Mr. Brett Allen Bursey Route 1, Box 93C Little Mountain, South Carolina 29076 Resident Inspector / Summer NPS c/o U. S. NRC P. O. Box 1047 Irmo, South Carolina 29063

?

L f

... p,,

.s...:.

+

A_.

o SEP ~15 '198D MEETING NOTICE DISTRIBUTION Docket File L. Rubenstein NRC PDR T. Speis Local PDR W. Johnston TIC B. Grimes NSIC H. Collins TERA F. Pagano LB #2 File S. Ramos H. Denton J. Stolz E. Case S. Hanauer D. Eisenhut P. Collins R. Purple D. Vassallo T. Novak D. Ziemann S. Varga R. Mattson T. Ippolito R. Schroeder R. A. Clark K. Kniel R. Reid D. Skovholt R. Tedesco G. Knighton J. Youngblood M. Ernst A. Schwencer R. Baer F. Miraglia E. Adensam J. R. Miller A. Thadani G. Lainas ACRS (16)

D. Crutchfield Attorney, OELD W. Russell OIE (3)

J. 01shinski OSD (7)

R. Vollmer Project Manager W. Kane R. Bosnnk Licensing Assistant MService

)

F. Schauer Receiptionist R. E. Jackson J. LeDoux, I&E G. Lear V. Moore l

V. Noonan I&E Headquarters S. Pawlicki I&E Region I V. Benaroya I&E Region II Z. Rosztoczy I&E Region III W. Haass I&E Region IV D. Muller I&E Region V R. Ballard W. Regan NRC

Participants:

J. D. Saltzman D. Ross P. Check R. Satterfield

0. Parr F. Rosa Others:

W. Butler W. Kreger R. W. Houston T. Murphy W. Gammill BCC: Applicant & Service List 4.