YLECTRIC ES OdswayPrare Deeember 7, 1989 I

I Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 i

ULNRC-2122 Dear Sirt DOCKET NUMBER 50-483 CALLAWAY PLANT UNIT 1 FACILITY OPERATING LICENSE NPF-30 MONTHLY OPERATING REPORT NOVEMBER 1989 The enclosed Monthly (cperating Report for November,1989 is submitted pursuant to section 6.9.1.8 of the Callaway Unit 1 Technical Specifications.

. D. Blosser i

Manager, Callaway Plant

/

Dif h $>' On JDE/DET/RDA/ TAM /RJM/ crc Enclosure cc Distribution attached

.8912200349 891130

--PDR -ADOCK 05000493 R-PDC i

Mahng A#ess' P.O Box 62Q Flitort MO 652S1

1h (h '.' ':

~

, g; 1

n,

~*

i I

cc distribution for ULNRC-2122' I

t i

f

.with enclosures i

- Mr. Robert DeFayette, Chief

.}

Project Section:1A-

[

U._S. Nuclear Regulatory Commission y

Region 1111 7-799 Roosevelt Road

[

Glen Ellyn IL 60137 F

l

[

Mr. Thomas Alexion (2 copies)

.I U. S. Nuclear Regulatory Commission

' Office of Nuclear Reactor Regulation

.)

' Mail Stop P-316

-j 7920 Norfolk Avenue i

ff

Bethesda, MD' 20014 i

3

+

r.

e l

NRC Resident Inspector iO Manager, Electric Department Missouri Public Service Commission i

P.-O. Box 360 l

D Jefferson City MO 65102 I

I i

- i I

~

r

(

I f

i.;

r 1

s i

t I

I 4

l k

'y

g j.,

1 F

..l ' -

u

. i'!?

/,9

o-

. 4 r,

~ DOCKET NO.

50-483

.lmIt'NAME CALLAWAY IMIT 1 ll-DAfE.

'12 07 89

.o COMPLETED BY R. J. McCann TELEPHONE 314/676 8243, s

fJ N

e PART A-OhERATIONS SIM4ARY

,V..

the plant operated at approximately 100% power with the following exception.

i.

, >^

i f i:

' 1.

On11/3/89loadwasreducEdtoapproximately20%inottertorepairanairlinefiltergasketfor

. normal RCS letdown flow control valves BC-14V-0459 and 0450. Tull power operation resumed early the next day.

l.,

'PART B.

PORY AND SAFETY VALVE SIMtARY

'None 3,

s h

1'

l..y, t,

1 l;

p Page 1 of 4
  • 'o 4

4$ "

t-

- { d;'

o

'i$,

. y.

Part C AVERACE DAILY UNIT POWEL LEVEL p,,

b-DOCKET NO.

50-483 UNIT NAME~

CALLAWAY UNIT 1

'DATE 12-07-89 COMPLE1ID BY R. J. McCann TELEPHONE 314/676 8243 4.,-

MONTH:

HOVEM8ER 1989 l

s'p AVERACE DAILY POWER LEVEL AVERACE DAILY POWER LEVEL M

(MWe Net)

.g (MWe Net) 1 1188-17 1188-2 1192 18 1191 3

869 19 1183 4-1032-20 1180-5 1175 21

-1190'

.6 1184 22 1192~

7

-1185 23.

1191

.j

'8' 1186 24 1186-

~

9' 1184 25' 1185 s

-10 1185 26 1186 11 1177' 27 1180 12 1179 28 1194 m

13 1167 29 1191 i

14 1171 30 1190 l -

15 1188 16 1191 Page 2 of 4

9,

.s N

'f-Part D OPERATING DATA REPORT j

e IXX'KET NO.

50 483 UNIT NAME CALLAWAY UNIT 1 DATE 12 07 89 COMPLETED BY R. J. McCann t:

TELEP110NE.

-314/676-8243 I

OPERATING STAITS e

(YTD CUN )

1.

REPORTINC PERIOD: NOVEMBER 1989 CROSS Il0URS IN REPORTING PERIOD:

720 8,016 43,357.$

l 2 CURRENTLY AUTil0RIZED POWER IIVEL (MWt):

3565 MAX. DEPEND. CAPACITY (MWe Net):- 1118 DESIGN ELECTRICAL RATINC (MWe Net):

1171 i

3.-

POWER LEVEL TO WIIICH RESTRICTED (IF ANY) (MWe Net):

t '

i; 4

REASONS FOR RESTRICTION (IF ANY):

{

THfS MONTil Ylt TO DATF

_CU_MULATIVE i

5.

NUMBER OF HOURS REACTOR WAS CRITICAL...............

720 6,737.6 37,236.4

.j i

6.

REACIVR RESERVE SHUTDOWN 110URS.....................

0 0

0 i'

7.. Il0URS CENERATOR ON LINE............................

MO -

6,625.9 36,210.4

-i 8.

UNIT PISERVE SIIUTDOWN ll0URS........................

0 0

0 9

CROSS TilERMAL ENERCY GENERATED (MWil)...............

2,529,924 22,903,373 138,789,984

10. CROSS ELECTRICAL ENERCY CENERATED (MWil)............

881,030 7,838,443 40,271,993 i

11. ' NET ELECTRICAL ENERCY CENERATED (MWH)..............

841,885 7,466,112 38,210,313 s

12.-. REACTOR SERVICE FACTOR.............................

100 84.1 85.9 i

13. REACTOR AVAILABILITY FACTOR........................

100 84.1 85.9

- 14 UNIT SERVICE FACTOR................................

100 82.7 83.5 i

i

15. UNIT AVAILABILITY FACTOR...........................

100 82.7-83.5.

i 16 UNIT CAPACITY FACTOR (Using MDC)...................

104.6 83.3 78.8

+.

17. - UNIT CAPACITY FACTOR (Us ing Des ign HWe)............

99.9 79.5 75.3

+

18. UNIT FORCED OUTAGE RATE............................

0 1.2 3.5 h

. 19. - SHUTDOWNS SCllEDULED OVER NEXT 6 HONTHS (TYPE, DATE, AND DURATION OF EACil):

20.-

IF Sl!UT DOWN AT END OF PIPORTING PERIOD, ESTIMATED DATE Of STARTUP:

i Page 3 of 4 i

I.-

.n.

g~

. ~c

.mm

= - - - -

a, -

4 26,.i a

Part E-

  • E**^

UNIT SHUTDOWNS AND POWER REDCCTIONS D00EI NO.

L50-483 ENIT NAPE "

CM.IAMT UNIT 1 DATE 12-07-89 COPFLETED BT l R. J.~McConn TELEPHONE 314/676-8243-REPORI MONIN: NOVEMBER 1989 4

MEIHOD OF TYPE SHUITING DOWN F: FORCED DURATION THE REACIUR OR

(^fj g

DATE S: SCHEDULED (HOURS)

REASON REDUCING POWER CURRECTTYE ACT10NS/ COP 9ENTS 13 11/3/89 F-0 A

1 On 11/3/89, load was reduced to approximately 20% in order to repair an air line filter gasket for normel RCS letdown flow control valves BC-LC7-0459 and 0%0. Full power operation resweed early the next day.

4 SU!91 ART:

REASON PETHO3 A EQUIPMENT FAIIIRE (EXPIAIN) 1: MANUAL B: MAINT. OR TEST 2: MANUAL SCRAM C: REFUELING 3: AUTOMATIC SCRAM D: REGULATORT RESTRICTION 4! OTHER (EXPIAIN)

E: OPERATOR TRAINING AND LICENSE EKAMINATION F: ADMINISTRATIVE G: OPERATIONAL ERROR (EXPLAIN)

H: OINEF (EXPLAIN)

Page 4 of 4-

.... ~..

~ ~.

..